This paper presents a low noise amplifier for large arrays of silicon photomultipliers (SiPMs) operated in cryogenic environments, especially liquid argon (87 K) and liquid nitrogen (77 K). The goal is for one amplifier to read out a total…

Instrumentation and Detectors · Physics 2020-01-15 P. Carniti , A. Falcone , C. Gotti , A. Lucchini , G. Pessina , S. Riboldi , F. Terranova

The photon detection system of the first far detector (FD1-HD) of the DUNE experiment will detect scintillation photons produced by particle interactions in a kiloton-scale liquid Argon time projection chamber. The photon detectors of…

Future high-energy physics experiments using SiPMs as photosensitive elements may require operation at low temperatures (down to 80 K) to measure single photons with high time resolution in a highly radioactive environment. This calls for a…

Instrumentation and Detectors · Physics 2026-02-02 P. Carniti , C. Gotti , G. Pessina , D. Trotta

The application of silicon photomultiplier (SiPM) technology for weak-light detection at a single photon level has expanded thanks to its better photon detection efficiency in comparison to a conventional photomultiplier tube (PMT). SiPMs…

Silicon photomultiplier (SiPM), a new type of photosensor, is considered a substitute for traditional photomultiplier tube (PMT) in the next generation of dark matter and neutrino detectors, especially in noble gas detectors like liquid…

Instrumentation and Detectors · Physics 2023-05-31 T. A. Wang , C. Guo , X. H. Liang , L. Wang , M. Y. Guan , C. G. Yang , J. C. Liu , F. Y. Lin

We report on the realization of a novel SiPM-based, cryogenic photosensor with an active area of 24 cm$^2$ that operates as a single-channel analog detector. The device is capable of single photon counting with a signal to noise ratio…

The operation of large arrays of silicon photomultipliers (SiPM) in tanks of noble liquids requires low noise, low power front-end amplifiers, able to operate reliably in the cryogenic environment. A suitable amplifier needs to be paired…

Instrumentation and Detectors · Physics 2023-10-09 P. Carniti , E. Cristaldo , A. Falcone , C. Gotti , G. Pessina , F. Terranova

Silicon photomultipliers (SiPM) have gained significant traction as an alternative technology to the well-established photomultiplier tube (PMT), with numerous high-sensitivity experiments adopting them either complementarily or as a…

Instrumentation and Detectors · Physics 2025-06-24 Giuseppe Matteucci

Silicon Photomultipliers (SiPMs) are photon-counting detectors with great potential to improve the sensitivity of optical receivers. Recent studies of SiPMs in communication focus on the speed rather than the power consumption of the…

Signal Processing · Electrical Eng. & Systems 2024-04-05 Yangchun Li , Danial Chitnis

We report on the characterization of near-ultraviolet high density silicon photomultiplier (\SiPM) developed at Fondazione Bruno Kessler (\FBK) at cryogenic temperature. A dedicated setup was built to measure the primary dark noise and…

Silicon Photomultipliers (SiPMs) are considered as a solid-state sensor alternative to photomultiplier tubes in experiments using liquid xenon (LXe) as a radiation detection medium. The main requirements are single-photon detection of the…

Instrumentation and Detectors · Physics 2018-11-14 Laura Baudis , Michelle Galloway , Alexander Kish , Chris Marentini , Julien Wulf

This article presents the development of a cost-effective and efficient electronic module for silicon photomultipliers (SiPM). The electronic module combines essential functionalities, such as a high voltage power supply, a preamplifier,…

Instrumentation and Detectors · Physics 2023-09-07 A. Sadigov , S. Nuruyev , R. Akbarov , D. B. Berikov , A. Madadzada , A. Mammadli

We present experimental results of characterization of Silicon photomultipliers (SiPM) in a temperature range from 90~mK to 40~K. Two SiPMs, one from ONSEMI and one from Hamamatsu Photonics were tested. Operating voltage ranges, dark count…

Instrumentation and Detectors · Physics 2025-01-13 Otto Hanski , Tom Kiilerich , Sampsa Ahopelto , Aleksei Semakin , Janne Ahokas , Viacheslav Dvornichenko , Sergey Vasiliev

Silicon photomultipliers (SiPMs) have a low radioactivity, compact geometry, low operation voltage, and reasonable photo-detection efficiency for vacuum ultraviolet light (VUV). Therefore it has the potential to replace photomultiplier…

Instrumentation and Detectors · Physics 2021-03-24 K. Ozaki , S. Kazama , M. Yamashita , Y. Itow , S. Moriyama

Next generation multi-ton scale noble liquid experiments have the unique opportunity to discover dark matter particles at the TeV scale, reaching the sensitivity of 10^-48 cm2 in the WIMP nucleon scattering cross-section. A prerequisite…

Instrumentation and Detectors · Physics 2016-01-07 S. Catalanotti , A. G. Cocco , G. Covone , M. D Incecco , G. Fiorillo , G. Korga , B. Rossi , S. Walker

Decreasing the operation temperature of a Silicon Photo-Multiplier (SiPM) leads to a drop in its dark noise. Some experiments consider cold temperatures as an option for low noise applications of SiPM. One of those is the TAO detector,…

Instrumentation and Detectors · Physics 2021-03-17 N. Anfimov , D. Fedoseev , A. Rybnikov , A. Selyunin , S. Sokolov , A. Sotnikov

We report on the performance of silicon photomultiplier (SiPM) light sensors operating in electric field strength up to 30 kV/cm and at a temperature of 149K, relative to their performance in the absence of an external electric field. The…

Instrumentation and Detectors · Physics 2018-10-17 X. L. Sun , T. Tolba , G. F. Cao , P. Lv , L. J. Wen , A. Odian , F. Vachon , A. Alamre , J. B. Albert , G. Anton , I. J. Arnquist , I. Badhrees , P. S. Barbeau , D. Beck , V. Belov , T. Bhatta , F. Bourque , J. P. Brodsky , E. Brown , T. Brunner , A. Burenkov , L. Cao , W. R. Cen , C. Chambers , S. A. Charlebois , M. Chiu , B. Cleveland , M. Coon , M. Côté , A. Craycraft , W. Cree , J. Dalmasson , T. Daniels , L. Darroch , S. J. Daugherty , J. Daughhetee , S. Delaquis , A. Der Mesrobian-Kabakian , R. DeVoe , J. Dilling , Y. Y. Ding , M. J. Dolinski , A. Dragone , J. Echevers , L. Fabris , D. Fairbank , W. Fairbank , J. Farine , S. Feyzbakhsh , P. Fierlinger , R. Fontaine , D. Fudenberg , G. Gallina , G. Giacomini , R. Gornea , G. Gratta , E. V. Hansen , D. Harris , M. Heffner , E. W. Hoppe , J. Hößl , A. House , P. Hufschmidt , M. Hughes , Y. Ito , A. Iverson , A. Jamil , C. Jessiman , M. J. Jewell , X. S. Jiang , A. Karelin , L. J. Kaufman , D. Kodroff , T. Koffas , S. Kravitz , R. Krücken , A. Kuchenkov , K. S. Kumar , Y. Lan , A. Larson , D. S. Leonard , G. Li , S. Li , Z. Li , C. Licciardi , Y. H. Lin , R. MacLellan , T. Michel , M. Moe , B. Mong , D. C. Moore , K. Murray , R. J. Newby , Z. Ning , O. Njoya , F. Nolet , O. Nusair , K. Odgers , M. Oriunno , J. L. Orrell , G. S. Ortega , I. Ostrovskiy , C. T. Overman , S. Parent , A. Piepke , A. Pocar , J. -F. Pratte , D. Qiu , V. Radeka , E. Raguzin , T. Rao , S. Rescia , F. Retière , A. Robinson , T. Rossignol , P. C. Rowson , N. Roy , R. Saldanha , S. Sangiorgio , S. Schmidt , J. Schneider , D. Sinclair , K. Skarpaas VIII , A. K. Soma , G. St-Hilaire , V. Stekhanov , T. Stiegler , M. Tarka , J. Todd , T. I. Totev , R. Tsang , T. Tsang , B. Veenstra , V. Veeraraghavan , G. Visser , J. -L. Vuilleumier , M. Wagenpfeil , Q. Wang , J. Watkins , M. Weber , W. Wei , U. Wichoski , G. Wrede , S. X. Wu , W. H. Wu , Q. Xia , L. Yang , Y. -R. Yen , O. Zeldovich , J. Zhao , Y. Zhou , T. Ziegler

Silicon photomultipliers (SiPMs) are potential solid-state alternatives to traditional photomultiplier tubes (PMTs) for single-photon detection. In this paper, we report on evaluating SensL MicroFC-10035-SMT SiPMs for their suitability as…

Silicon photomultipliers (SiPM) are solid state light detectors with sensitivity to single photons. Their use in high energy physics experiments, and in particular in ring imaging Cherenkov (RICH) detectors, is hindered by their poor…

Instrumentation and Detectors · Physics 2019-01-16 M. Calvi , P. Carniti , C. Gotti , C. Matteuzzi , G. Pessina

The detection of individual photons at cryogenic temperatures is of interest to many experiments searching for physics beyond the Standard Model. Silicon photomultipliers (SiPMs) are often deployed in liquid argon or liquid xenon to detect…

Instrumentation and Detectors · Physics 2025-05-22 S. Borden , J. A. Detwiler , W. Pettus , N. W. Ruof