Related papers: Glass-based charged particle detector performance …
An axial gas ionization chamber has been fabricated for use as a $\Delta E$ detector in heavy ion induced nuclear reactions. Different operating parameters such as gas type, pressure, anode voltage and anode structures have been optimized.…
Two-dimensional solid state gaseous detector for thermal and cold neutrons is created. The detector has active area of 128 x 128 $mm^2$, $^{10}B$ neutron converter, and gas chamber with thin windows. The resistive charge-division readout is…
Prepared for the 2014 ISAPP summer school, this review is focused on space-borne and balloon-borne cosmic-ray and gamma-ray detectors. It is meant to introduce the fundamental concepts necessary to understand the instrument performance…
We present a concept for on-orbit radio detection of ultra-high energy cosmic rays (UHECRs) that has the potential to provide collection rates of ~100 events per year for energies above 10^20 eV. The synoptic wideband orbiting radio…
As observed on the signal of the Planck-HFI highly sensitive bolometers, the effect of cosmic rays on detectors is a major concern for future similar space missions. Their instruments will have a larger detection surface, increased…
The ATLAS experiment will undergo a major upgrade of the tracker system in view of the high luminosity phase of the LHC (HL-LHC) foreseen to start around 2025. Thin planar pixel modules are promising candidates to instrument the new pixel…
The characteristics of a hydrogenated amorphous silicon (a-Si:H) detector are presented here for monitoring in space solar flares and the evolution of large energetic proton events up to hundreds of MeV. The a-Si:H presents an excellent…
The Transition Edge Sensor is extremely sensitive to the change of temperature, combined with the high-Z metal of a certain thickness, it can realize the high energy resolution measurement of particles such as X-rays. X-rays with energies…
The paper reviews recent progress in photodetectors, discussing vacuum-based detectors, semiconductor sensors, and gas-based detectors. The emphasis in this review is on the detection of low light levels, enhanced timing resolution, and…
A thick gas electron multiplier is considered for radiation-hard detectors (hadron calorimeter). There was carried out technological and design study to optimize the element structure. The measurements results and the next plans are…
In order to develop a high spatial resolution (micron level) thermal neutron detector, a detector assembly composed of cerium doped lithium glass microfibers, each with a diameter of 1\,$\mu$m, is proposed, where the neutron absorption…
A radiation detector based on plasma display panel technology, which is the principal component of plasma television displays is presented. Plasma Panel Sensor (PPS) technology is a variant of micropattern gas radiation detectors. The PPS…
The Detector Control System (DCS) of the COMPASS experiment at CERN is presented. The experiment has a high level of complexity and flexibility and a long time of operation, that constitute a challenge for its full monitorisation and…
A high-granularity telescope system with a large sensitive area and low material budget has been developed for high-energy heavy ion beam tests. The telescope consists of nine layers of silicon microstrip detectors (SSDs), whose performance…
A new diagnosis method for high energy ions utilizing a single CR-39 detector mounted on plastic plates is demonstrated to identify the presence of the high energy component beyond the CR-39's detection threshold limit. On irradiation of…
The Particle Flow Analysis approach retained for the future ILC detectors requires high granularity and compact particle energy deposition. A Glass Resistive Plate Chamber based Semi-Digital calorimeter can offer both at a low price for the…
Recent advancements in particle physics demand pixel detectors that can withstand increased luminosity in the future collider experiments. In response, MALTA, a novel monolithic active pixel detector, has been developed with a cutting-edge…
We propose a high resolution spatial diagnostic method via inserting a millimeter-gap grating into the collimated terahertz beam to monitor the minute variation of the terahertz beam in strong-field terahertz sources, which is difficult to…
High energy cosmic rays, with energies thousands of times higher than those encountered in particle accelerators, offer scientists the means of investigating the elementary properties of matter. In order to detect high energy cosmic rays,…
We report about the experimental set-up designed for the development of an innovative particle detector based on solid crystals of inert gases. The hybrid detection scheme, that exploits the electrons emission through the solid-vacuum…