Related papers: Characterizing a CCD detector for astronomical pur…
The formalism for computing the signal-to-noise ratio (SNR) for laser radar is reviewed and applied to the tasks of target detection, direction-finding, and phase change estimation with squeezed light. The SNR for heterodyne detection of…
Understanding the noise characteristics of high quantum efficiency silicon-based ultraviolet detectors, developed by the Microdevices Lab at the Jet Propulsion Laboratory, is critical for current and proposed UV missions using these…
Charge-coupled devices (CCDs) are a leading technology in direct dark matter searches because of their eV-scale energy threshold and high spatial resolution. The sensitivity of future CCD experiments could be enhanced by distinguishing…
This work shows details of an evaluation of an observational system comprising a CMOS detector, 60-cm telescope, and filter complement. The system's photometric precision and differential photometric precision, and extinction coefficients…
A variety of on-orbit imaging and spectroscopic observations are used to characterize the Charge Transfer Efficiency (CTE) of the Charge-Coupled Device (CCD) of the Space Telescope Imaging Spectrograph (STIS) aboard the Hubble Space…
The Multiple Amplifier Sensing Charge-Coupled Device (MAS-CCD) has emerged as a promising technology for astronomical observation, quantum imaging, and low-energy particle detection due to its ability to reduce the readout noise without…
We present our latest ASIC, which is used for the readout of Cadmium Telluride double-sided strip detectors (CdTe DSDs) and high spectroscopic imaging. It is implemented in a 0.35 um CMOS technology (X-Fab XH035), consists of 64 readout…
We discuss the flight calibration of the spectral response of the Advanced CCD Imaging Spectrometer (ACIS) on-board the Chandra X-ray Observatory (CXO). The spectral resolution and sensitivity of the ACIS instrument have both been evolving…
Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their high spatial resolution and thin sensitive layers make them an excellent tool for studying short-lived…
Low noise CCDs fully-depleted up to 675 micrometers have been identified as a unique tool for Dark Matter searches and low energy neutrino physics. The charge collection efficiency (CCE) for these detectors is a critical parameter for the…
We report a measurement of the ionization efficiency of silicon nuclei recoiling with sub-keV kinetic energy in the bulk silicon of a charge-coupled device (CCD). Nuclear recoils are produced by low-energy neutrons ($<$24 keV) from a…
The Swift X-ray Telescope focal plane camera is a front-illuminated MOS CCD, providing a spectral response kernel of 135 eV FWHM at 5.9 keV as measured before launch. We describe the CCD calibration program based on celestial and on-board…
Future strategic X-ray missions, such as the Advanced X-ray Imaging Satellite (AXIS) and those targeted by the Great Observatories Maturation Program (GOMaP), require fast, low-noise X-ray imaging spectrometers. To achieve the speed and…
In this thesis we have analysed the time evolution of the photometric precision achieved by the space-based exoplanet-hunting mission CoRoT during its flight phase (2007-2012). This study of the noise level of CoRoT light curves has been…
The flight calibration of the spectral response of CCD instruments below 1.5 keV is difficult in general because of the lack of strong lines in the on-board calibration sources typically available. We have been using 1E 0102.2-7219, the…
CII is one of the brightest emission lines from star-forming galaxies and is an excellent tracer for star formation. Recent work measured the CII emission line amplitude for redshifts $2<z<3.2$ by cross-correlating Planck High Frequency…
A readout electronics used in space cosmic-ray charges measurement for multi-channel silicon detector and its performance test results are introduced in this paper. A 64-channel charge sensitive ASIC (VA140) from IDEAS company is adopt in…
We present prototype modules for a tracking detector consisting of multiple layers of 0.25 mm diameter scintillating fibers that are read out by linear arrays of silicon photomultipliers. The module production process is described and…
We report recent results on the use of charge division to obtain a longitudinal coordinate from silicon strip detectors, and on sources of electronic readout noise for long, thin strips. These results hold promise for the design of Linear…
A Scintillator Deposited CCD (SDCCD) is a wide-band X-ray detector consisting of a CCD and a scintillator directly attached to each other. We assembled the newly developed SDCCD that the scintillator CsI(Tl) is below the fully depleted CCD.…