Related papers: A Generalized Short Circuit Ratio for Multi-Infeed…
The renewable energy is connected to the power grid through power electronic converters, which are lack of make the inertia of synchronous generator/machine (SM) be lost. The increasing penetration of renewable energy in power system…
In this paper, we propose state- and static output-feedback generalized guaranteed cost control (GCC) approaches for discrete-time linear systems subject to norm-bounded structured parametric uncertainties. This method enables the convex…
In the last decades, various events have shown that electromechanical oscillations are a major concern for large interconnected Alternative Current (AC) power systems. DC segmentation - a method that consist in turning large AC grids into a…
Synchronous condensers (SCs) have been reported to improve the overall stability and short-circuit power of a power system. SCs are also being integrated into offshore wind power plants (WPPs) for the same reason. This paper, investigates…
Nyquist criterion-based impedance ratio criteria (IRCs) have been widely applied for inspecting the risk of small-signal instability among converter-based AC power systems. Aided by a comparative study on voltage source converter, including…
Grid-forming voltage source converter (GF-VSC) has been identified as the key technology for the operation of future converter-dominated power systems. Among many other issues, transient stability of this type of power systems remains an…
This brief examines the behavior of DC circuits comprised of resistively interconnected constant power devices, as may arise in DC microgrids containing micro-sources and constant power loads. We derive a sufficient condition for all…
We have developed novel impedance standards based on thin-film surface-mount-device (SMD) resistors. Due to the small dimensions of such resistors, the quantities determining their frequency dependence are very small and can be either…
Integration of distributed energy resources has created a need for autonomous, dynamic voltage regulation. Decentralized Volt-VAr Control (VVC) of grid-connected inverters presents a unique opportunity for voltage management but, if…
Due to significant manufacturing process variations, the performance of integrated circuits (ICs) has become increasingly uncertain. Such uncertainties must be carefully quantified with efficient stochastic circuit simulators. This paper…
In the last decades, various events have shown that electromechanical oscillations are a major concern for large interconnected Alternating Current (AC) power systems. Segmentation of AC power systems with High Voltage Direct Current (HVDC)…
Impedance-based stability analysis is appealing in the case of Single-Input Single-Output (SISO) systems. However, in the case of grid-tied voltage source converter (VSC) systems, dq impedances of source and load (VSC) subsystems are…
A new method for stability assessment of inverter-based microgrids is presented in this paper. It leverages the notion of critical clusters -- a localized group of inverters with parameters having the highest impact on the system stability.…
Modern power system is undergoing a paradigm shift from the synchronous generators-based system to the power electronics converters-dominated system. With the high penetration of converters, serious stability problems are provoked,…
Assessing small-signal stability of power systems composed of thousands of interacting generators is a computationally challenging task. To reduce the computational burden, this paper introduces a novel condition to assess and certify…
The short-term voltage stability (SVS) problem in large-scale receiving-end power systems is serious due to the increasing load demand, the increasing use of electronically controlled loads and so on. Some serious blackouts are considered…
This article presents input-output stability analysis of nonlinear feedback systems based on the notion of soft and hard scaled relative graphs (SRGs). The soft and hard SRGs acknowledge the distinction between incremental positivity and…
For high wind power-penetrated power systems, the multiple renewable energy station short-circuit ratio (MRSCR) is often insufficient due to weak grid structures. Additionally, transient voltage sag/overvoltage issues may cause trip faults…
With the growing penetration of Inverter-Based Resources (IBRs) in power systems, stability service markets have emerged to incentivize technologies that ensure power system stability and reliability. Among the various challenges faced in…
The AC frequency in electrical power systems is conventionally regulated by synchronous machines. The gradual replacement of these machines by asynchronous renewable-based generation, which provides little or no frequency control, increases…