Related papers: A HEMT-Based Cryogenic Charge Amplifier with sub-1…
We have designed and characterized a cryogenic amplifier for use in $^3$He NMR spectrometry. The amplifier, with a power consumption of $\sim 2.5$ mW, works at temperatures down to 4~K. It has a hi-impedance input for measuring a signal…
Cryogenic semiconductor detectors operated at temperatures below 100 mK are commonly used in particle physics experiments searching for dark matter. The largest such germanium and silicon detectors, with diameters of 100 mm and thickness of…
Cryogenic calorimeters for low-mass dark matter searches have achieved sub-eV energy resolutions, driving advances in both low-energy calibration techniques and our understanding of detector physics. The energy deposition spectrum of gamma…
We report first results from the Cryogenic Dark Matter Search (CDMS II) experiment running with its full complement of 30 cryogenic particle detectors at the Soudan Underground Laboratory. This report is based on the analysis of data…
Recent progress on the development of very low noise high purity germanium ionization spectrometers has produced an instrument of 1.2 kg mass and excellent noise performance. The detector was installed in a low-background cryostat intended…
Light, MeV-scale dark matter (DM) is an exciting DM candidate that is undetectable by current experiments. A germanium (Ge) detector utilizing internal charge amplification for the charge carriers created by the ionization of impurities is…
For the first time, time-dependent internal charge amplification through impact ionization has been observed in a planar germanium (Ge) detector operated at cryogenic temperature. In a time period of 30 and 45 minutes after applying a bias…
An electron-on-helium qubit is a promising physical platform for quantum information technologies. Among all the "blueprints" for the qubit realization, a hybrid Rydberg-spin qubit seems to be a promising one towards quantum computing using…
Cryogenic phonon detectors with transition-edge sensors achieve the best sensitivity to light dark matter-nucleus scattering in current direct detection dark matter searches. In such devices, the temperature of the thermometer and the bias…
The EDELWEISS collaboration has performed a search for Dark Matter (DM) particles interacting with electrons using a 33.4 g Ge cryogenic detector operated underground at the LSM. A charge resolution of 0.53 electron-hole pairs (RMS) has…
The discrimination capabilities of a 70 g heat and ionization Ge bolometer are studied. This first prototype has been used by the EDELWEISS Dark Matter experiment, installed in the Laboratoire Souterrain de Modane, for direct detection of…
The baseline energy-resolution performance for the current generation of large-mass, low-temperature calorimeters (utilizing TES and NTD sensor technologies) is $>2$ orders of magnitude worse than theoretical predictions. A detailed study…
The Cryogenic Dark Matter search experiment (CDMS) employs low-temperature Ge and Si detectors to detect WIMPs via their elastic scattering of target nuclei. The last analysis with an germanium exposure of 397.8 kg-days resulted in zero…
We present the technical design for the SuperCDMS high-voltage, low-mass dark matter detectors, designed to be sensitive to dark matter down to 300 MeV/$c^2$ in mass and resolve individual electron-hole pairs from low-energy scattering…
The RICOCHET reactor neutrino observatory is planned to be installed at the Laue Langevin Institute (ILL) starting mid-2022. Its scientific goal is to perform a low-energy and high precision measurement of the coherent elastic…
The EDELWEISS collaboration aims for direct detection of light dark matter using germanium cryogenic detectors with low threshold phonon sensor technologies and efficient charge readout designs. We describe here the development of Ge…
A 100um thick silicon detector with 1mm2 pad readout optimized for sub-nanosecond time resolution has been developed and tested. Coupled to a purposely developed amplifier based on SiGe HBT technology, this detector was characterized at the…
The DAMIC experiment uses fully depleted, high resistivity CCDs to search for dark matter particles. With an energy threshold $\sim$50 eV$_{ee}$, and excellent energy and spatial resolutions, the DAMIC CCDs are well-suited to identify and…
We present limits on the spin-independent interaction cross section of dark matter particles with silicon nuclei, derived from data taken with a cryogenic calorimeter with 0.35 g target mass operated in the CRESST-III experiment. A baseline…
The SuperCDMS experiment is designed to directly detect weakly interacting massive particles (WIMPs) that may constitute the dark matter in our Galaxy. During its operation at the Soudan Underground Laboratory, germanium detectors were run…