Related papers: A HEMT-Based Cryogenic Charge Amplifier with sub-1…
The cryogenic performance of GaN-based HEMTs (high-electron-mobility transistors) is systematically investigated by the direct current (DC) and low-frequency noise (LFN) characteristics within the temperature (T) range from 300 K to 4.2 K.…
Weakly Interacting Massive Particles (WIMPs) may constitute a large fraction of the matter in the Universe. There are excess events in the data of DAMA/LIBRA, CoGeNT, CRESST-II, and recently CDMS-Si, which could be consistent with WIMP…
We have developed a highly-sensitive integrated capacitance bridge for quantum capacitance measurements. Our bridge, based on a GaAs HEMT amplifier, delivers attofarad (aF) resolution using a small AC excitation at or below kT over a broad…
The InGaAs-InAlAs-InP high electron mobility transistor (InP HEMT) is the preferred active device used in a cryogenic low noise amplifier (LNA) for sensitive detection of microwave signals. We observed that an InP HEMT 0.3-14GHz LNA at 2K,…
Scintillating, cryogenic bolometers are widely used in the field of rare event searches. Their main advantages are an excellent energy resolution and particle identification on an event-by-event basis. The sensitivity of experiments…
Large-scale superconducting quantum computers require massive numbers of high-performance cryogenic low-noise amplifiers (cryo-LNA) for qubit readout. Here we present a C-Band monolithic microwave integrated circuit (MMIC) cryo-LNA for this…
We calibrate a two-phase xenon detector at 0.27 keV in the charge channel and at 2.8 keV in both the light and charge channels using a $^{37}$Ar source that is directly released into the detector. We map the light and charge yields as a…
The gamma-ray line from dark matter (DM) annihilation is too weak to observe, but its observation will uncover much information, e.g., the DM mass and an nomalously large annihilation rate $\sim0.1$ pb into di-photon. In this work, we…
The DRIFT-IId dark matter detector is a m$^3$-scale low-pressure TPC with directional sensitivity to WIMP-induced nuclear recoils. Its primary backgrounds were due to alpha decays from contamination on the central cathode. Efforts to reduce…
We point out that power measurements of single quasiparticle devices open a new avenue to detect dark matter (DM). The threshold of these devices is set by the Cooper pair binding energy, and is therefore so low that they can detect DM as…
The Cryogenic Dark Matter Search (CDMS) employs Ge and Si detectors to search for WIMPs via their elastic-scattering interactions with nuclei while discriminating against interactions of background particles. CDMS data give limits on the…
Cavity optomechanical systems have recently been proposed as detectors for ultralight dark matter, leveraging their ability to cool and probe mechanical oscillators at the quantum limit. Here we present a resonant search for ultralight dark…
In the last decade direct detection Dark Matter (DM) experiments have increased enormously their sensitivity and ton-scale setups have been proposed, especially using germanium and xenon targets with double readout and background…
We present results of a dark matter search performed with a 0.6 kg day exposure of the DAMIC experiment at the SNOLAB underground laboratory. We measure the energy spectrum of ionization events in the bulk silicon of charge-coupled devices…
The EDELWEISS collaboration reports on the search for Dark Matter (DM) particle interactions via Migdal effect with masses between $32$ MeV$\cdot$c$^{-2}$ to $2$ GeV$\cdot$c$^{-2}$ using a $200$ g cryogenic Ge detector sensitive to…
We report a measurement of the ionization efficiency of silicon nuclei recoiling with sub-keV kinetic energy in the bulk silicon of a charge-coupled device (CCD). Nuclear recoils are produced by low-energy neutrons ($<$24 keV) from a…
The cryogenic detectors in the form of bolometers are presently used for different applications, in particular for very rare or hypothetical events associated with new forms of matter, specifically related to the existence of Dark Matter.…
We present an innovative charge detector with high resolution and wide dynamic range designed to fulfill the requirements of a monitoring system for a high energy ion beam. The detector prototype, constructed using Si photodiodes and a…
We made global fits of the inert Higgs doublet model (IDM) in the light of collider and dark matter search limits and the requirement for a strongly first-order electroweak phase transition (EWPT). These show that there are still IDM…
We are conducting an experiment to search for WIMPs, or weakly-interacting massive particles, in the galactic halo using terrestrial detectors. This generic class of hypothetical particles, whose properties are similar to those predicted by…