Related papers: The lower limit for time resolution in frequency m…
A promising technique for measuring single electron spins is magnetic resonance force microscopy (MRFM), in which a microcantilever with a permanent magnetic tip is resonantly driven by a single oscillating spin. If the quality factor of…
Atomic force microscopes (AFMs) are ubiquitous in research laboratories and have recently been priced for use in teaching laboratories. Here we review several AFM platforms (Dimension 3000 by Digital Instruments, EasyScan2 by Nanosurf,…
We consider an oscillator model to describe qualitatively friction force for an atomic force mi-croscope (AFM) tip driven on a surface described by periodic potential. It is shown that average value of the friction force could be controlled…
Atomic Force Microscopy (AFM) has become established as a powerful and a versatile tool for investigating local mechanical properties. In addition, it has been made possible to take advantage of the AFM tip-sample interaction, to perturb,…
We investigate the capillary force that applies on a tilted cylinder as a function of its dipping angle i, using a home-built tilting Atomic Force Microscope (AFM) with custom made probes. A micrometric-size rod is glued at the end of an…
A detailed analysis of the most relevant sources of phase noise in an atomic interferometer is carried out, both theoretically and experimentally. Even a short interrogation time of 100 ms allows our cold atom gravimeter to reach an…
We report on Magnetic Resonance Force Microscopy measurements of the Boltzmann polarization of the nuclear spins in copper by detecting the frequency shift of a soft cantilever. We use the time-dependent solution of the Bloch equations to…
We discuss the influence of external forces on the motion of the tip in dynamic atomic force microscopy (AFM). First, a compact solution for the steady-state problem is derived employing a Fourier approach. Founding on this solution, we…
We measure the mechanical thermal noise of soft silicon atomic force microscopy cantilevers. Using an interferometric setup, we have a resolution down to 1E-14 m/rtHz on a wide spectral range (3 Hz to 1E5 Hz). The low frequency behavior…
A method is presented for calibrating the higher eigenmodes (resonance modes) of atomic force microscopy cantilevers that can be performed prior to any tip-sample interaction. The method leverages recent efforts in accurately calibrating…
The potential of photon detectors to achieve precise timing information is of increasing importance in many domains, PET and CT scanners in medical imaging and particle physics detectors, amongst others. The goal to increase by an order of…
A low cost scheme to determine the frequency sweep nonlinearity using atomic saturated absorption spectroscopy is demonstrated. The frequency modulation rate is determined by directly measuring the interference fringe number and frequency…
We present a detailed exposition of the design for time- and angle-resolved photoemission spectroscopy using a UV probe laser source that combines the nonlinear effects of \b{eta}-BaB2O4 and KBe2BO3F2 optical crystals. The photon energy of…
The performance of the GlueX Forward Calorimeter was studied using a small version of the detector and a variable energy electron beam derived from the Hall B tagger at Jefferson Lab. For electron energies from 110 MeV to 260 MeV, which are…
The aim of this article is to provide a complete analysis of the behavior of a noncontact atomic force microscope (NC-AFM). We start with a review of the equations of motion of a tip interacting with a surface in which the stability…
As mechanical devices in the nano/micro length scale are increasingly employed, it is crucial to understand nanoscale friction and wear especially at technically relevant sliding velocities. Accordingly, a novel technique has been developed…
Significant progress has been made in spatial resolution using environmental transmission electron microscopes (ETEM), which now enables atomic resolution visualization of structural transformation under variable temperature and gas…
We report a new experimental technique for Kelvin probe force microscopy (KPFM) using the dissipation signal of frequency modulation atomic force microscopy for bias voltage feedback. It features a simple implementation and faster scanning…
The time resolution of a double-stage Thick-GEM (THGEM) detector was measured with UV-photons and relativistic electrons. The photon detector, with semitransparent- or reflective-photocathode yielded time resolution of about 8-10ns RMS for…
The resolution of any spectroscopic or interferometric experiment is ultimately limited by the total time a particle is interrogated. We here demonstrate the first molecular fountain, a development which permits hitherto unattainably long…