English
Related papers

Related papers: Performance Studies of Bulk Micromegas of Differen…

200 papers

In this study, we investigate the influence of humidity on the performance of various non-resistive Micro Pattern Gaseous Detectors, such as GEM, Thick-GEM, and Micromegas, operated with \ArCOtwo gas mixture. The water content is introduced…

Instrumentation and Detectors · Physics 2025-08-22 H. Fribert , L. Fabbietti , P. Gasik , B. Ulukutlu

The Inner Tracker System of the HERA-B experiment at DESY consists of 184 Microstrip Gas Chambers (MSGC) with a total number of 147 456 electronic read out channels. The detectors have to cope with particle fluxes up to 25 kHz/mm**2 and to…

Instrumentation and Detectors · Physics 2007-05-23 Bernhard Schmidt

Gaseous detectors are fundamental components of all present and planned high energy physics experiments. Over the past decade two representatives (GEM, Micromegas) of the Micro-Pattern Gas Detector (MPGD) concept have become increasingly…

Instrumentation and Detectors · Physics 2008-11-26 Maxim Titov

We describe a work of a multi-cathode counter of the developed design in a single electron counting mode with a cathode made of aluminum alloy. The results of the calibration of the counter are presented. The coefficient of gas…

Instrumentation and Detectors · Physics 2018-10-17 A. V. Kopylov , I. V. Orekhov , V. V. Petukhov

In the last few years our group have focused on developing various designs of spark-protected micropattern gaseous detectors featuring resistive electrodes instead of the traditional metallic ones: resistive microstrip counters, resistive…

Instrumentation and Detectors · Physics 2015-06-04 P. Fonte , E. Nappi , P. Martinengo , R. Oliveira , V. Peskov F. Pietropaolo , P. Picchi

The complex ac impedance of a bolometer or microcalorimeter detector is easily measured and can be used to determine thermal time constants, thermal resistances, heat capacities, and sensitivities. Accurately extracting this information…

Instrumentation and Detectors · Physics 2009-04-13 John E. Vaillancourt

THGEMs (THick Gas Electron Multiplier) of varying thickness, hole diameter and hole pitch have been studied. For a thinner-THGEM of thickness 0.2 mm, with hole diameter 0.2 mm, pitch 0.2 mm and narrow (5-10 {\mu}m) rim, the performance of…

High Energy Physics - Experiment · Physics 2015-06-03 H. B. Liu , Q. Liu , S. Chen , C. Nicholson , Y. G. Xie , Y. H. Zheng , Z. P. Zheng , J. G. Lu , L. Zhou , A. S. Tang , Y. D. Yang , Y. Dong , M. Li

We report new results obtained in calibrations of superheated liquid droplet detectors used in dark matter searches with different radiation sources (n,$\alpha$,$\gamma$). In particular, detectors were spiked with alpha-emitters located…

Systematic studies on the gain and the energy resolution have been carried out varying the voltage across the GEM foils for both single mask and double mask triple GEM detector prototypes. Variation of the gain and the energy resolution…

Instrumentation and Detectors · Physics 2016-06-22 S. Biswas , D. J. Schmidt , A. Abuhoza , U. Frankenfeld , C. Garabatos , J. Hehner , V. Kleipa , T. Morhardt , C. J. Schmidt , H. R. Schmidt , J. Wiechula

For its ease manufacturing, flexible geometry, and cheap manufacturing cost, the gas electron multiplier (GEM) detector can be used as an x-ray image sensor. For this purpose, we acquired relative detection efficiencies and suggested a…

Instrumentation and Detectors · Physics 2015-03-13 Sukyoung Shin , Jaehoon Jung , Soonhyouk Lee

The experimental - calculated method is proposed to determine the full energy peak efficiency (FEPE) of detectors {\epsilon}(E) in case a measurement of the large-volume samples. Water is used as standard absorber in which the linear…

Instrumentation and Detectors · Physics 2012-07-20 E. G. Tertyshnik , A. T. Korsakov

The gas gain and energy resolution of single and double THGEM detectors (5{\times}5cm2 effective area) with mini-rims (rim is less than 10{\mu}m) were studied. The maximum gain can reach 5{\times}103 and 2{\times}105 for single and double…

A high spatial resolution tracking system was setup with the Micro-mesh gaseous structure (Micromegas) detectors in order to study the muon tomographic imaging technique for nuclear threat detection. 6 layers of 90 mm $\times$ 90 mm…

Instrumentation and Detectors · Physics 2022-09-12 Liu Cheng-Ming , Wen Qun-Gang , Zhang Zhi-Yong , Huang Guang-Shun

Optically read out gaseous detectors are used in track reconstruction and imaging applications requiring high granularity images. Among resolution-determining factors, the amplification stage plays a crucial role and optimisations of…

Instrumentation and Detectors · Physics 2024-07-23 A. Cools , E. Ferrer-Ribas , T. Papaevangelou , E. C. Pollacco , M. Lisowska , F. M. Brunbauer , E. Oliveri , F. J. Iguaz

To extend the acceptance of the CMS muon spectrometer to the region 2.4 $<|\eta|<$ 2.8, stacks of triple-GEM chambers, forming the ME0 station, are planned for the CMS Phase 2 Upgrade. These large-area micro-pattern gaseous detectors must…

To meet the need for a high counting rate and high time resolution in future high-energy physics experiments, a prototype of a gas photodetector with an RPC structure was developed. Garfield++ simulated the detector's performance, and the…

Instrumentation and Detectors · Physics 2024-07-30 Yiding Zhao , D. Hu , M. Shao , Y. Zhou , S. Lv , Xiangqi Tian , Anqi Wang , Xueshen Lin , Hao Pang , Y. Suna

We show that measured optical transmittance of an ultra thin gas depends on the detector size. To this end we conducted an experiment that compares transmittances measured in parallel with a pair of detectors with different diameters…

Instrumentation and Detectors · Physics 2021-03-19 Jakub M. Ratajczak

We report the calibration of a gaseous Time Projection Chamber based on Micromegas charge readout modules with cosmic ray muons, utilizing their penetrating power and relatively uniform energy deposition per unit length. Muon events were…