English

MSGC Development for HERA-B

Instrumentation and Detectors 2007-05-23 v1 High Energy Physics - Experiment

Abstract

The Inner Tracker System of the HERA-B experiment at DESY consists of 184 Microstrip Gas Chambers (MSGC) with a total number of 147 456 electronic read out channels. The detectors have to cope with particle fluxes up to 25 kHz/mm**2 and to tolerate radiation doses of 1 Mrad per year. During the development of these chambers it was found that conventional MSGC, operated in intenses hadronic fluxes, are rapidly destroyed due to induced discharges. The introduction of a Gas Electron Multiplier (GEM) as pre-amplification structure offers the possibility to build robust and reliable detectors allowing for ample gain reserve in the hostile environment of HERA-B.

Keywords

Cite

@article{arxiv.physics/9804035,
  title  = {MSGC Development for HERA-B},
  author = {Bernhard Schmidt},
  journal= {arXiv preprint arXiv:physics/9804035},
  year   = {2007}
}

Comments

17 pages, 15 figures.Paper presented at the 36th Workshop of the INFN Eloisatron Project on New Detectors, 1.-7. November 1997, Erice, Italy