Related papers: Performance Studies of Bulk Micromegas of Differen…
Whilst the performance of small THGEMs is well known, here we consider the challenges in scaling these up to large area charge readouts. We first verify the expected gain of larger THGEMs by reporting experimental Townsend coefficients for…
A novel gaseous two-dimensional imaging detector "Micro Pixel Chamber (micro-PIC)" has been developed. This detector is based on double sided printed circuit board (PCB). We have developed large area (10cm x 10cm) micro-PICs with 65536…
Gas electron multipliers (GEMs) with wire (WGEMs) or metal electrodes (MGEMs), which don't use any plastic insulators between the electrodes are created. The absence of plastic insulation between the electrodes of WGEMs excludes unwanted…
In this study we report the results of a systematic study of the gain, rate and the position resolution limits of various micropattern gaseous detectors. It was found that at low rates (<1 Hz/mm^2) each detector has it own gain limit, which…
We briefly review the concept and properties of the Thick GEM (THGEM); it is a robust, high-gain gaseous electron multiplier, manufactured economically by standard printed-circuit drilling and etching technology. Its operation and structure…
The new beam profile measurement for the Antiproton Decelerator (AD) at CERN is based on a single Gas Electron Multiplier (GEM) with a 2D readout structure. This detector is very light (~0.4% X0), and measures horizontal and vertical…
We report on the optimization of discharge insensitive floating strip Micromegas (MICRO-MEsh GASeous) detectors, fit for use in high-energy muon spectrometers. The suitability of these detectors for particle tracking is shown in…
A full-size prototype of a Micromegas precision tracking chamber for the upgrade of the ATLAS detector at the LHC Collider has been built between October 2015 and April 2016. This paper describes in detail the procedures used in…
It is well known and has been shown that the gain performance of Gaseous Electron Multipliers (GEM) depends on the size of the holes. With an optical scanner it is possible to measure the dimensions of the holes, and to predict the…
A MicroCAT (Micro Compteur A Trous) structure which is used for avalanche charge multiplication in gas filled radiation detectors has been optimised with respect to maximum electron transparency and minimum ion feedback. We report on the…
Micromegas is presently in use by many experiments providing enhanced performance when used in high particle environment. Compared with other solid-state detectors or conventional gas counters Micromegas is robust and radiation hard. Recent…
We further study the performance of single, double and triple Gas Electron Multiplier (GEM) detectors in pure noble gases at high pressures, in the range of 1-10 atm. We confirm that light noble gases, in particular He and its mixtures with…
In recent years Gas Electron Multipliers have proven to be reliable amplification stages at high beam rates, and can be used also in Time Projection Chambers. Our group developed a 1 dm$^3$ active volume double-GEM TPC, with spatial…
This work is proposing and exploring the use of multichannel readout electronics, already used in quality assurance for gain uniformity studies, to measure the uniformity of the induction gap in GEM based detectors. The measurement will…
In view of a possible application as a charge-particle track readout for an Active-Target Time Projection Chamber (AT-TPC), the operational properties and performances of a hybrid Micro-Pattern Gaseous Detector (MPGD) were investigated in…
Gaseous detectors are used in high energy physics as trackers or, more generally, as devices for the measurement of the particle position. For this reason, they must provide high spatial resolution and they have to be able to operate in…
Micro-Pattern Gaseous Detectors (MPGDs) with resistive anode planes provide intrinsic discharge robustness while maintaining good spatial and time resolutions. Typically read out with 1D strips or pad structures, here the characterisation…
Five small prototype micromegas detectors were positioned in the ATLAS detector during Large Hadron Collider running at $\sqrt{s} = 7$ and $8\, \mathrm{TeV}$. A $9\times 4.5\, \mathrm{cm^2}$ double drift gap detector was placed in front of…
Basic R & D have been carried out with one small straw tube detector prototype with premixed gas of Ar+CO2 in 70:30 and 90:10 ratio. The gain and the energy resolution are measured with Fe55 X-ray source. Effect of temperature and pressure…
The design of multi-channel gas electron multiplier (MGEM) with metallic electrodes is proposed, produced and tested. The electrodes of MGEM are produced from the brass plates with thickness of 1 mm, round openings of 1 mm in diameter and…