English
Related papers

Related papers: Charge Distribution Dependency on Gap Thickness of…

200 papers

The reduction of the average charge per count in the gas along with the capability to discriminate very small signals from noise can allow an efficient and long-term Resistive Plate Chamber detector operation in high radiation background…

Instrumentation and Detectors · Physics 2020-12-30 Luca Pizzimento

Principles of operation, construction and first test results of a Dielectric Resistive Plate Chamber (DRPC) are described. The detector has shown stability of operation in the avalanche mode of gas amplfication within a wide range of…

Instrumentation and Detectors · Physics 2007-05-23 A. Akindinov , V. Golovin , A. Martemiyanov , V. Petrov , A. Smirnitskiy , K. Voloshin

Resistive Plate Chambers have a very important role for muon triggering both in the barrel and in the endcap regions of the CMS experiment at the Large Hadron Collider (LHC). In order to optimize their performance, it is of primary…

Instrumentation and Detectors · Physics 2020-06-03 W. Elmetenawee

We report on measurements of charge transfer in GEM structures in high magnetic fields. These were performed in the framework of the R&D work for a Time Projection Chamber at a future Linear Collider. A small test chamber has been installed…

Instrumentation and Detectors · Physics 2009-11-10 M. Killenberg , S. Lotze , J. Mnich , A. Muennich , S. Roth , F. Sefkow , M. Tonutti , M. Weber , P. Wienemann

A new readout technique was developed with the primary aim of keeping the number of channels in the front-end electronics as low as possible when scaling up the sensitive area of a Resistive Plate Chamber (RPC). The readout method here…

Instrumentation and Detectors · Physics 2024-07-16 João Pedro de Carvalho Saraiva , Alberto Blanco Castro

A large volume Time Projection Chamber (TPC) is being considered for the central charged particle tracker for the detector for the proposed International Linear Collider (ILC). To meet the ILC-TPC spatial resolution challenge of ~100…

Instrumentation and Detectors · Physics 2008-11-26 K. Boudjemline , M. S. Dixit , J. -P. Martin , K. Sachs

An experimental setup consisting of 12 layers of glass Resistive Plate Chambers (RPCs) of size 2\,m\,$\times$\,2\,m has been built at IICHEP-Madurai (\ang{9;56;14.5}\,N \ang{78;00;47.9}\,E, on the surface) to study the long term performance…

High Energy Astrophysical Phenomena · Physics 2020-12-14 Suryanarayan Mondal , V. M. Datar , Gobinda Majumder , N. K. Mondal , S. Pethuraj , K. C. Ravindran , B. Satyanarayana

In this document the density of electrically-charged positive and negative particles in a two component plasma (TCP) will be studied. Particularly, we focus on a two dimensional system confined in a large rectangular box for $\Gamma=2$ in…

Statistical Mechanics · Physics 2021-05-03 Alejandro Ferrero Botero

The India-based Neutrino Observatory (INO) is a project aimed at building a large underground laboratory to explore the Earth's mater effects on the atmospheric neutrinos in multi-GeV range. INO will host a 50 kton magnetized iron…

Instrumentation and Detectors · Physics 2020-01-29 A. K. Sikdar , J. Sadiq , P. K. Behera

This paper reports on detailed measurements of the performance of Resistive Plate Chambers in a proton beam with variable intensity. Short term effects, such as dead time, are studied using consecutive events. On larger time scales, for…

Instrumentation and Detectors · Physics 2009-06-25 B. Bilki , J. Butler , E. May , G. Mavromanolakis , E. Norbeck , J. Repond , D. Underwood , L. Xia , Q. Zhang

The inner surfaces of the electrodes encompassing the gas volume of a Resistive Plate Chamber (RPC) have been found to exhibit asperities with, grossly, three kinds of features. The desired uniform electric field within the gas volume of…

Instrumentation and Detectors · Physics 2016-06-27 Abhik Jash , Nayana Majumdar , Supratik Mukhopadhyay , Subhasis Chattopadhyay

Timing characteristics of two multigap RPCs were compared. One had four subgaps 0.3 mm wide and the other - two subgaps 0.6 mm wide. Specially developed electronics was used. Electronics resolution convoluted with measured charge spectra at…

High Energy Physics - Experiment · Physics 2007-05-23 V. Ammosov , V. Gapienko , A. Ivanilov , A. Semak , Yu. Sviridov , E. Usenko , V. Zaets

The Time Projection Chamber (TPC) for the International Linear Collider will need to measure about 200 track points with a resolution close to 100 $\mu$m. A Micro Pattern Gas Detector (MPGD) readout TPC could achieve the desired resolution…

We have constructed and tested a 2d position sensitive parallel-plate gas ionization chamber with scanned charge transfer readout. The scan readout method described here is based on the development of a new position dependent charge…

Instrumentation and Detectors · Physics 2009-11-10 F. Gomez , A. Iglesias , R. Lobato , J. Mosquera , J. Pardo , J. Pena , A. Pazos , M. Pombar , A. Rodriguez

Large Resistive Plate Chamber systems have their roots in High Energy Physics experiments at the European Organization for Nuclear Research: ATLAS, CMS and ALICE, where hundreds of square meters of both trigger and timing RPCs have been…

Instrumentation and Detectors · Physics 2022-11-30 João Saraiva , Carlos Alemparte , Daniel Belver , Alberto Blanco , Juan Callón , Jose Collazo , Alfredo Iglesias , Luís Lopes

The Resistive Plate Chamber (RPC) is widely used in experiments of high energy physics as trigger detector as its good time resolution and high efficiency. In the traditional layout of RPC, the graphite layers are indispensable parts. The…

Instrumentation and Detectors · Physics 2021-08-31 Quanyin Li , Xiangyu Xie , Zhengwei Xue , Jiajin Ge , Yongjie Sun

A new prototype of large area Multi-gap Resistive Plate Chamber (MRPC) with long readout strips was built. This Long-strip Multi-gap Resistive Plate Chamber (LMRPC) is double stacked and has ten 250 $\mu$m-thick gas gaps. Signals are read…

Instrumentation and Detectors · Physics 2015-05-20 Yongjie sun , Cheng Li , Zebo Tang , Lailin Xu , Tianxiang Chen , Ming Shao

The Multigap Resistive Plate Chamber (MRPC) is a gaseous detector; the performance depends very much on the gas mixture as well as the design. MRPCs are used as a timing device in several collider experiments and cosmic ray experiments…

Instrumentation and Detectors · Physics 2019-03-27 Yongwook Baek , Dowon Kim , M. C. S. Williams

This paper studies the space charge impedances of a rectangular beam inside a rectangular chamber, and the limiting case, e.g., a rectangular beam between parallel plates, respectively. The charged beam has uniform density in vertical…

Accelerator Physics · Physics 2014-07-08 Yingjie Li , Lanfa Wang

The Resistive Plate Chambers detector system at the CMS experiment at the LHC provides robustness and redundancy to the muon trigger. A total of 1056 double-gap chambers cover the pseudo-rapidity region < 1.6. The main detector parameters…

Instrumentation and Detectors · Physics 2016-05-31 Mehar Ali Shah