English

Effect of plate roughness on the field near RPC plates

Instrumentation and Detectors 2016-06-27 v2 High Energy Physics - Experiment

Abstract

The inner surfaces of the electrodes encompassing the gas volume of a Resistive Plate Chamber (RPC) have been found to exhibit asperities with, grossly, three kinds of features. The desired uniform electric field within the gas volume of RPC is expected to be affected due to the presence of these asperities, which will eventually affect the final response from the detector. In this work, an attempt has been made to model the highly complex roughness of the electrode surfaces and compute its effect on the electrostatic field within RPC gas chamber. The calculations have been performed numerically using Finite Element Method (FEM) and Boundary Element Method (BEM) and the two methods have been compared in this context.

Keywords

Cite

@article{arxiv.1605.02163,
  title  = {Effect of plate roughness on the field near RPC plates},
  author = {Abhik Jash and Nayana Majumdar and Supratik Mukhopadhyay and Subhasis Chattopadhyay},
  journal= {arXiv preprint arXiv:1605.02163},
  year   = {2016}
}

Comments

7 pages, 12 figures, 1 table