English
Related papers

Related papers: Effect of plate roughness on the field near RPC pl…

200 papers

The working of a resistive plate chamber depends on the electric field applied inside the gas gap. The strength of this electric field inside the gas gap depends on parameters like electrode thickness, permittivity, gas gap, among others.…

Instrumentation and Detectors · Physics 2022-05-03 Tanay Dey , Supratik Mukhopadhyay , Subhasis Chattopadhyay

A numerical model based on Finite Element Method (FEM) has been developed to simulate the electrical properties of RPC utilizing the law of current conservation. It has been used to systematically investigate the effect of the electrical as…

High Energy Physics - Experiment · Physics 2022-10-12 Subhendu Das , Jaydeep Datta , Nayana Majumdar , Supratik Mukhopadhyay

Performances of several single gap (gas gap 2 mm) prototype Resistive Plate Chambers (RPC) made of high resistive ({\rho} \sim 1010 - 1012 {\Omega} cm) bakelite, commercially available in India have been studied in recent times. To make the…

Instrumentation and Detectors · Physics 2015-06-05 S. Biswas , Purba Bhattacharya , S. Bhattacharya , S. Bose , S. Chattopadhyay , N. Majumdar , S. Mukhopadhyay , S. Saha , Y. P. Viyogi

Resistive plate chamber (RPC) is one of the state-of-the-art particle detection technology for the High Energy Physics (HEP) experiments. The basic operating mechanism of an RPC involves ionization of gas due to the passage of charged…

Instrumentation and Detectors · Physics 2020-12-30 Tanay Dey , Supratik Mukhopadhyay , Subhasis Chattopadhyay , Jhilam Sadukan

Electric field noise is a major source of motional heating in trapped ion quantum computation. While the influence of trap electrode geometries on electric field noise has been studied in patch potential and surface adsorbate models, only…

Atomic Physics · Physics 2016-08-24 Kuan-Yu Lin , Guang Hao Low , Issac L. Chuang

Single gap (gas gap 2 mm) bakelite Resistive Plate Chamber (RPC) modules of various sizes from 10 cm \times 10 cm to 1 m \times 1 m have been fabricated, characterized and optimized for efficiency and time resolution. Thin layers of…

Instrumentation and Detectors · Physics 2015-06-05 K. K. Meghna , A. Banerjee , S. Biswas , S. Bhattacharya , S. Bose , S. Chattopadhyay , G. Das , C. Marick , S. Saha , Y. P. Viyogi

The intrinsic rate capability and the ageing properties of the Resistive Plate Chambers are closely related to the electrodes material and to the front-end electronics threshold. The development of a low noise pre-amplifier led us to…

This paper reports on the performance of Resistive Plate Chambers (RPCs) as function of the gas flow rate through the chambers and of environmental conditions, such as atmospheric pressure, ambient temperature and air humidity. The chambers…

Instrumentation and Detectors · Physics 2010-05-07 Burak Bilki , John Butler , Ed May , Georgios Mavromanolakis , Edwin Norbeck , Jose Repond , David Underwood , Lei Xia , Qingmin Zhang

We present surface pictures of the damaged electrodes from the Glass Resistive Plate Chambers (GRPCs) taken by an Atomic Force Microscope (AFM). For the test, a set of chambers were operated with freon mixed gas (damaged) and freonless gas…

High Energy Physics - Experiment · Physics 2007-05-23 T. Kubo , E. Nakano , Y. Teramoto

Resistive Plate Chamber (RPC) is one of the most commonly used detectors in high energy physics experiments for triggering and tracking because of its good efficiency ($\textgreater$~90\%) and time resolution ($\sim$~1-2~ns). Generally,…

Instrumentation and Detectors · Physics 2025-03-21 A. Sen , S. Mandal , S. Chatterjee , S. Gope , S. Das , S. Biswas

Resistive Plate Chambers (RPCs) exhibit a significant loss of efficiency for the detection of particles, when subjected to high particle fluxes. This rate limitation is related to the usually high resistivity of the resistive plates used in…

Instrumentation and Detectors · Physics 2015-09-08 M. Affatigato , U. Akgun , B. Bilki , F. Corriveau , B. Freund , N. Johnson , C. Neubueser , Y. Onel , J. Repond , L. Xia

The behavior of lipid membranes in the presence of an external electric field is studied and used to examine the influence of such fields on membrane parameters such as roughness and show that for a micro sized membrane, roughness grows as…

Soft Condensed Matter · Physics 2007-11-12 M Neek-Amal , H. Rafii-Tabar , H. R. Sepangi

Resistive Plate Chambers (RPCs) are essential active media of large-scale experiments as part of the muon systems and (semi-)digital hadron calorimeters. Among the several outstanding issues associated with the RPCs, the loss of efficiency…

Instrumentation and Detectors · Physics 2023-07-19 Mehmet Tosun , Burak Bilki , Kutlu Kagan Sahbaz

Understanding the electrodes' surface morphology influence on the ions' distribution is essential for designing the supercapacitors with enhanced energy density characteristics. We develop a model for the structure of electrolytes near the…

Statistical Mechanics · Physics 2021-06-30 Timur Aslyamov , Konstantin Sinkov , Iskander Akhatov

Numerical calculations have been performed to understand the reason for the observed non-uniform response of a Resistive Plate Chamber (RPC) in a few critical regions such as near edge spacers and corners of the device. In this context, the…

Instrumentation and Detectors · Physics 2016-09-23 Abhik Jash , Nayana Majumdar , Supratik Mukhopadhyay , Satyajit Saha , Subhasis Chattopadhyay

This paper presents the study on the characterization of glass electrodes, which are one of the main components of detectors like Resistive Plate Chambers (RPCs). The RPCs are being used in various ongoing High Energy Physics experiments,…

Instrumentation and Detectors · Physics 2022-03-01 R. Kanishka , V. Bhatnagar

We present approximate methods for calculating the three-dimensional electric potentials of finite surface electrodes including gaps between electrodes, and estimate the effects of finite electrode thickness and an underlying dielectric…

Quantum Physics · Physics 2010-02-27 Roman Schmied

This paper reports on detailed measurements of the performance of Resistive Plate Chambers in a proton beam with variable intensity. Short term effects, such as dead time, are studied using consecutive events. On larger time scales, for…

Instrumentation and Detectors · Physics 2009-06-25 B. Bilki , J. Butler , E. May , G. Mavromanolakis , E. Norbeck , J. Repond , D. Underwood , L. Xia , Q. Zhang

Resistive Plate Chamber (RPC) is a well-known gaseous detector in the field of High Energy Physics (HEP) experiments for its good tracking capability, high efficiency, good time resolution, and low cost of fabrication. The main issue in RPC…

Instrumentation and Detectors · Physics 2024-01-25 A. Sen , S. Chatterjee , S. Das , S. Biswas

Micro-Electro-Mechanical Systems (MEMS) normally have fixed or moving structures (plates or array of thin beams) with cross-sections of the order of microns and lengths of the order of tens or hundreds of microns. Electrostatic forces play…

Computational Physics · Physics 2007-05-23 N. Majumdar , S. Mukhopadhyay
‹ Prev 1 2 3 10 Next ›