English
Related papers

Related papers: Sensitive Phase Gratings for X-ray Phase Contrast …

200 papers

Phase-wrapping artifacts, statistical image noise and the need for a minimum amount of phase steps per projection limit the practicability of x-ray grating based phase-contrast tomography, when using filtered back projection reconstruction.…

X-ray imaging, traditionally relying on attenuation contrast, struggles to differentiate materials with similar attenuation coefficients like soft tissues. X-ray phase contrast imaging (XPCI) and dark-field (DF) imaging provide enhanced…

Medical Physics · Physics 2025-06-05 Jingcheng Yuan , Mini Das

For a century, clinical X-ray imaging has visualised only the attenuation properties of tissue, which fundamentally limits the contrast, particularly in soft tissues like the breast. Imaging based on refraction can overcome this limitation,…

Imaging with hard x-rays is an invaluable tool in medicine, biology, materials science, and cultural heritage. Propagation-based x-ray phase-contrast imaging and tomography have been mostly used to resolve micrometer-scale structures inside…

Image and Video Processing · Electrical Eng. & Systems 2025-06-02 Margie P. Olbinado , David M. Paganin , Yin Cheng , Alexander Rack

Diffractive optical elements such as periodic gratings are fundamental devices in X-ray imaging - a technique that medical, material science and security scans rely upon. Fabrication of such structures with high aspect ratios at the…

X-ray phase contrast imaging offers a way to visualize the internal structures of an object without the need to deposit any radiation, and thereby alleviate the main concern in x-ray diagnostic imaging procedures today. Grating-based…

X-ray micro tomography is a non-destructive, three-dimensional inspection technique applied across a vast range of fields and disciplines, ranging from research to industrial, encompassing engineering, biology and medical research.…

X-ray imaging has conventionally relied upon attenuation to provide contrast. In recent years, two complementary modalities have been added; phase contrast and dark-field x-ray imaging, capturing weakly attenuating and sub-pixel sample…

Optics · Physics 2021-11-16 Kaye S. Morgan , David M. Paganin

Phase contrast X-ray imaging (PCXI) is an emerging imaging modality that has the potential to greatly improve radiography for medical imaging and materials analysis. PCXI makes it possible to visualise soft-tissue structures that are…

X-ray interferometry is an emerging imaging modality with a wide variety of potential clinical applications, including lung and breast imaging, as well as in non-destructive testing, such as additive manufacturing and porosimetry. A grating…

Grating interferometer is a state of art x-ray imaging approach, which can simultaneously acquire information of x-ray attenuation, phase shift, and small angle scattering. This approach is very sensitive to micro-structural variation and…

Medical Physics · Physics 2015-09-21 Wenxiang Cong , Yan Xi , Ge Wang

Despite the fact that the resolution of conventional contact/proximity lithography can reach feature sizes down to ~0.5-0.6 micrometers, the accurate control of the linewidth and uniformity becomes already very challenging for gratings with…

Phase-contrast and dark-field imaging are relatively new X-ray imaging modalities that provide additional information to conventional attenuation-based imaging. However, this new information comes at the price of a more complex acquisition…

Using higher-order coherence of thermal light sources, the resolution power of standard x-ray imaging techniques can be enhanced. In this work, we applied the higher-order measurement to far-field x-ray diffraction and near-field phase…

Phase-contrast imaging is an emerging technology that may increase the signal-difference-to-noise ratio in medical imaging. One of the most promising phase-contrast techniques is Talbot interferometry, which, combined with energy-sensitive…

The low-density imaging performance of a zone plate based nano-resolution hard X-ray computed tomography (CT) system can be significantly improved by incorporating a grating-based Lau interferometer. Due to the diffraction, however, the…

Image and Video Processing · Electrical Eng. & Systems 2023-10-16 Xuebao Cai , Yuhang Tan , Ting Su , Dong Liang , Hairong Zheng , Jinyou Xu , Peiping Zhu , Yongshuai Ge

Future NASA X-ray spectroscopy missions will require high throughput, high resolution grating spectrometers. Off-plane reflection gratings are capable of meeting the performance requirements needed to realize the scientific goals of these…

X-ray phase-contrast imaging has the potential to improve image contrast with lower dose by probing an object's refractive properties as well as its absorptive properties. To reconstruct a phase-contrast image from a raw dataset, a phase…

Medical Physics · Physics 2025-08-19 Giavanna Jadick , Patrick La Rivière

X-ray phase-contrast imaging has experienced rapid development over the last few decades, and in this technology, the phase modulation strategy of phase-stepping is used most widely to measure the sample's phase signal. However, because of…

Medical Physics · Physics 2017-12-06 Faiz Wali , Shenghao Wang , Huajie Han , Kun Gao , Zhao Wu , Peiping Zhu , Yangchao Tiana

Diffraction gratings have been proposed as core optical elements in future laser-interferometric gravitational-wave detectors. In this paper we derive equations for the coupling between alignment noise and phase noise at diffraction…

General Relativity and Quantum Cosmology · Physics 2009-12-10 A. Freise , A. Bunkowski , R. Schnabel