Related papers: Microsecond resolved electron density measurements…
Hairpin probes measure electron density in plasmas where other techniques are unsuitable. Previous hairpins were constructed as a quarter-wave resonant structure typically made from a folded piece of wire. The present work conducts the…
Plasma impedance probes (PIPs) are a type of RF probe that primarily measure electron density. This work introduces two advancements: a streamlined analytical model for interpreting PIP-monopole measurements and techniques for achieving…
The measurement of electron cloud densities in particle accelerators using microwaves has proven to be an effective, non-invasive and inexpensive method. So far the experimental schemes have used continuous waves. This has either been in…
We have used optically excited ultrashort electrical pulses to measure the magnetoplasmon resonance of a two-dimensional electron gas formed in an AlGaAs/GaAs heterostructure at frequencies up to 200 gigahertz. This is accomplished by…
Microwave reflectance probed photoconductivity (or $\mu$-PCD) measurement represents a contactless and non-invasive method to characterize impurity content in semiconductors. Major drawbacks of the method include a difficult separation of…
This work proposes a novel method of Thomson microwave scattering for electron number density measurements of miniature plasmas at pressures < 10 Torr. This method is applied to determine electron number density in a positive column of glow…
The available diagnostics for atmospheric micro-plasmas remain limited and relatively complex to implement; so we present a radio-frequency technique for diagnosing a key parameter here. The technique allows one to estimate the dependencies…
In this work, Rayleigh microwave scattering was utilized to measure the electron number density produced by nanosecond high voltage breakdown in air between two electrodes in a pin-to-pin configuration (peak voltage 26 kV and pulse duration…
We measured for the first time the electron density in an Extreme Ultra-Violet induced plasma. This is achieved in a low-pressure argon plasma by using a method called microwave cavity resonance spectroscopy. The measured electron density…
Langmuir probe techniques have been used to study time and spatially resolved electron densities and electron temperatures in pulse-modulated hydrogen discharges in two different planar microwave reactors (fmicrowave= 2.45 GHz, tpulse= 1…
A system of automated computerized Langmuir probe measurements is used in order to determine the plasma parameters in a plasma reactor constructed for cleaning of metallic artifacts by RF discharge. A compensated probe insures the…
Electron neutral collision frequency is measured using both grounded and floating hairpin resonator probes in a 27 MHz parallel plate capacitively coupled plasma (CCP). Operating conditions are 0.1-2 Torr (13.3-267 Pa) in Ar, He, and Ar-He…
We describe instrumentation designed to perform millimeter-wave conductivity measurements in pulsed high magnetic fields at low temperatures. The main component of this system is an entirely non-metallic microwave resonator. The resonator…
High power pulsed magnetron sputtering (HPPMS) plasmas are pulsed discharges where the plasma composition as well as the fluxes and energies of ions are changing during the pulse. The time resolved energy distribution for Ar$^{1+}$ ions was…
We employ ultra-broadband terahertz-midinfrared probe pulses to characterize the optical response of photoinduced charge-carrier plasmas in high-resistivity silicon in a reflection geometry, over a wide range of excitation densities…
Instruments to visualize transient structural changes of inhomogeneous materials on the nanometer scale with atomic spatial and temporal resolution are demanded to advance materials science, bioscience, and fusion sciences. One such…
An accelerator beam can generate low energy electrons in the beam-pipe, generally called electron cloud, that can produce instabilities in a positively charged beam. One method of measuring the electron cloud density is by coupling…
We present pulsed electrically detected magnetic resonance (EDMR) measurements at low magnetic fields using posphorus-doped silicon with natural isotope composition as a model system. Our measurements show that pulsed EDMR experiments, well…
A simple, low-cost millimeter-wave (70 GHz) interferometer with a phase accuracy better than plus or minur 2 degrees, and a response time of 10 ns is described. The simplicity of this interferometer makes it ideal for measurement of…
We present theoretical and experimental results on the generation and detection of pulsed, relative-intensity squeezed light in a hot Rb87 vapor. The intensity noise correlations between a pulsed probe beam and its conjugate, generated…