English
Related papers

Related papers: Dual Position Sensitive MWPC for tracking reaction…

200 papers

A simple routine is proposed for monitoring the efficiency value of a low pressure pentane filled multi-wire proportional chamber (MWPC) in long term experiments. The proposed algorithm utilizes a two parameter approximation for the…

Instrumentation and Detectors · Physics 2023-08-01 Yu. S. Tsyganov , D. Ibadullayev , A. N. Polyakov , V. B. Zlokazov

A prototype multiwire proportional chamber (MWPC) was developed to demonstrate the feasibility of constructing a radiopure time projection chamber with MWPC track readout to assay materials for alpha- and beta-emitting surface contaminants…

Instrumentation and Detectors · Physics 2015-06-16 Z. Ahmed , M. A. Bowles , R. Bunker , S. R. Golwala , D. R. Grant , M. Kos , R. H. Nelson , A. Rider , R. W. Schnee , D. Sotolongo , B. Wang , A. Zahn

The Dark Matter Time Projection Chamber (DMTPC) is a direction-sensitive detector designed to measure the direction of recoiling $^{19}$F and $^{12}$C nuclei in low-pressure CF$_4$ gas using optical and charge readout systems. In this…

Instrumentation and Methods for Astrophysics · Physics 2017-06-21 Cosmin Deaconu , Michael Leyton , Ross Corliss , Gabriela Druitt , Richard Eggleston , Natalia Guerrero , Shawn Henderson , Jeremy Lopez , Jocelyn Monroe , Peter Fisher

Wire chambers are routinely operated as tracking detectors in magnetic spectrometers at high-intensity continuous electron beams. Especially in experiments studying reactions with small cross-sections the reaction yield is limited by the…

A 3-D position sensitive neutron detector is being developed based on a plastic scintillator array. A double side SiPM readout is used to determine the depth of interaction (DOI) in each scintillator unit. In the preliminary test, the DOI…

Instrumentation and Detectors · Physics 2019-07-11 Yang Tian , Yidong Fu , Yulan Li , Yuanjing Li

A prototype of Multi-Wire Proportional Chambers (MWPC) has been fabricated for the study of its various characteristics. The detector contains gold-coated tungsten wires (20 $\mu m$ diameter) on the anode frame, with a pitch of 2.8 mm. The…

Instrumentation and Detectors · Physics 2021-10-06 Rajendra Nath Patra , R. N. Singaraju , S. Biswas , T. K. Nayak , Y. P. Viyogi

Principles of operation, construction and first test results of a Dielectric Resistive Plate Chamber (DRPC) are described. The detector has shown stability of operation in the avalanche mode of gas amplfication within a wide range of…

Instrumentation and Detectors · Physics 2007-05-23 A. Akindinov , V. Golovin , A. Martemiyanov , V. Petrov , A. Smirnitskiy , K. Voloshin

The VAMOS++ magnetic spectrometer is a multi-parametric system that integrates ion optical magnetic elements with a multi-detector stack. The magnetic elements, along with the tracking and timing detectors and the trajectory reconstruction…

Instrumentation and Detectors · Physics 2025-08-14 M. Rejmund , A. Lemasson

The use of differential phase contrast (DPC) in scanning transmission electron microscopy (STEM) has shown much promise for directly investigating the functional properties of a material system, leveraging the natural coupling between the…

Materials Science · Physics 2025-12-04 Rafael V. Ferreira , Sebastian Calderon V. , Paulo J. Ferreira

Dual phase Xenon Time Projection Chambers (XeTPCs) are being used by several experiments as a promising technique for direct detection of dark matter. We report on the design and performance of a small 3-D sensitive dual phase XeTPC. The…

Instrumentation and Detectors · Physics 2015-06-17 Qing Lin , Yuehuan Wei , Jie Bao , Jie Hu , Xinran Li , Wolfgang Lorenzon , Kaixuan Ni , Michael Schubnell , Mengjiao Xiao , Xiang Xiao

Central exclusive processes can be studied in CMS by combining the information of the central detector with the Precision Proton Spectrometer (PPS). PPS detectors, placed symmetrically at more than 200 m from the interaction point, can…

Instrumentation and Detectors · Physics 2020-06-24 Edoardo Bossini

By correlating nuclear recoil directions with the Earth's direction of motion through the Galaxy, a directional dark matter detector can unambiguously detect Weakly Interacting Massive Particles (WIMPs), even in the presence of backgrounds.…

A new timing detector measuring ~50 MeV/c positrons is under development for the MEG II experiment, aiming at a time resolution $\sigma_t \sim 30~\mathrm{ps}$. The resolution is expected to be achieved by measuring each positron time with…

Instrumentation and Detectors · Physics 2016-05-23 P. W. Cattaneo , M. De Gerone , F. Gatti , M. Nishimura , W. Ootani , M. Rossella , S. Shirabe , Y. Uchiyama

We report high-bandwidth charge sensing measurements using a GaAs quantum point contact embedded in a radio frequency impedance matching circuit (rf-QPC). With the rf-QPC biased near pinch-off where it is most sensitive to charge, we…

Mesoscale and Nanoscale Physics · Physics 2009-11-13 D. J. Reilly , C. M. Marcus , M. P. Hanson , A. C. Gossard

The dijet double-differential cross section is measured as a function of the dijet invariant mass, using data taken during 2010 and during 2011 with the ATLAS experiment at the LHC, with a center-of-mass energy of 7 TeV. The measurements…

High Energy Physics - Experiment · Physics 2013-08-05 Iftach Sadeh

Diffractive scattering of $\gamma^* p \to X + N$, where $N$ is either a proton or a nucleonic system with $M_N~<~4$~GeV has been measured in deep inelastic scattering (DIS) at HERA. The cross section was determined by a novel method as a…

High Energy Physics - Experiment · Physics 2012-08-27 ZEUS Collaboration

The Multi-Pixel Photon Counter (MPPC) or Silicon Photomultiplier (SiPM) can detect from a single photon to several thousand ones; it has high gain -$10^{5}$ to $10^{6}$-, low operation voltage -65 to 75 Vdc-, and small size -typically 3.85…

Instrumentation and Detectors · Physics 2023-05-18 L. Arceo , J. Félix

Proportional scintillation counters (PSCs), both single- and dual-phase, can measure the scintillation (S1) and ionization (S2) channels from particle interactions within the detector volume. The signal obtained from these detectors depends…

Instrumentation and Detectors · Physics 2016-03-23 Kareem Kazkaz , Tenzing Henry Yatish Joshi

Multiple-input multiple-output (MIMO) radar offers several performance and flexibility advantages over traditional radar arrays. However, high angular and Doppler resolutions necessitate a large number of antenna elements and the…

Signal Processing · Electrical Eng. & Systems 2025-09-11 Chandrashekhar Rai , Himali Singh , Arpan Chattopadhyay
‹ Prev 1 2 3 10 Next ›