Related papers: Ultra-Low Noise Mechanically Cooled Germanium Dete…
Tiny vibrations of mechanical structures are the main limiting cause in a number of high sensitivity measurement apparatus, chief among them the most sensitive displacement apparatus on earth: gravitational wave interferometers. Such…
We report on the realization of a high sensitivity RF noise measurement scheme to study small current fluctuations of mesoscopic systems at milliKelvin temperatures. The setup relies on the combination of an interferometric ampli- fication…
Cooling down nanomechanical force probes is a generic strategy to enhance their sensitivities through the concomitant reduction of their thermal noise and mechanical damping rates. However, heat conduction mechanisms become less efficient…
The performance of a 630g commercial broad energy germanium (BEGe) detector has been systematically investigated. Energy resolution, linearity, stability vs. high-voltage (HV) bias, thickness and uniformity of dead layers have been measured…
This article reviews the state of rapidly emerging terahertz hot-electron nanobolometers (nano-HEB), which are currently among of the most sensitive radiation power detectors at submillimeter wavelengths. With the achieved noise equivalent…
Point-contact p-type high-purity germanium detectors (PPC HPGe) are particularly suited for detection of sub-keV nuclear recoils from coherent elastic scattering of neutrinos or light dark matter particles. While these particles are…
Shot noise encodes additional information not directly inferable from simple electronic transport measurements. Previous measurements in atomic-scale metal junctions at cryogenic temperatures have shown suppression of the shot noise at…
The design and performance of a low-noise, modular cryogenic probe, applicable to a wide range of measurements over a broad range of working frequencies, temperatures, and magnetic fields is presented. The design of the probe facilitates…
The gravitational waveform of merging binary neutron stars encodes information about extreme states of matter. Probing these gravitational emissions requires the gravitational-wave detectors to have high sensitivity above 1 kHz. Fortunately…
Low background gamma spectrometry employing HPGe detectors is a sensitive technique for measuring low-level radioactivity in environmental applications, material screening, and for rare decay searches. This work presents spectroscopic…
Advances in cryogenic electron microscopy have opened new avenues for probing quantum phenomena in correlated materials. This study reports the installation and performance of a new side-entry condenZero cryogenic cooling system for JEOL…
We present the design and implementation of a mechanical low-pass filter vibration isolation used to reduce the vibrational noise in a cryogen-free dilution refrigerator operated at 10 mK, intended for scanning probe techniques. We discuss…
Internal charge amplification (ICA) in cryogenic high-purity germanium (HPGe) can lower detection thresholds by providing gain inside the detector crystal, but reliable operation requires a predictive estimate of the avalanche-onset…
Low-temperature detectors often use mechanical coolers as part of the cooling chain in order to reach sub-Kelvin operating temperatures. The microphonics noise caused by the mechanical coolers is a general and inherent issue for these…
Light, MeV-scale dark matter (DM) is an exciting DM candidate that is undetectable by current experiments. A germanium (Ge) detector utilizing internal charge amplification for the charge carriers created by the ionization of impurities is…
We present a noise estimation and subtraction algorithm capable of increasing the sensitivity of heterodyne laser interferometers by one order of magnitude. The heterodyne interferometer is specially designed for dynamic measurements of a…
We report the on-wafer characterization of $S$-parameters and microwave noise temperature ($T_{50}$) of discrete metamorphic InGaAs high electron mobility transistors (mHEMTs) at 40 K and 300 K and over a range of drain-source voltages…
The Boulby Underground Germanium Suite (BUGS) comprises three low background, high-purity germanium detectors operating in the Boulby Underground Laboratory, located 1.1 km underground in the north-east of England, UK. BUGS utilises three…
High Purity Germanium (HPGe) detectors have been golden standard for gamma spectrometry in Low level radioactive waste (LLW) analysis; however, their notable shortcoming is prolonged measurement durations for weak radioactive waste…
State-of-the-art physics experiments require high-resolution, low-noise, and low-threshold detectors to achieve competitive scientific results. However, experimental environments invariably introduce sources of noise, such as electrical…