Related papers: Ultra-Low Noise Mechanically Cooled Germanium Dete…
A new type of radiation detector, a p-type modified electrode germanium diode, is presented. The prototype displays, for the first time, a combination of features (mass, energy threshold and background expectation) required for a…
Recent progress on the development of very low noise high purity germanium ionization spectrometers has produced an instrument of 1.2 kg mass and excellent noise performance. The detector was installed in a low-background cryostat intended…
A new ultra-low background high-purity germanium (HPGe) detector has been installed at the Kamioka underground experimental site. The background count rate in the energy range from 40 keV to 2700 keV is about 25% lower than that of the…
Germanium ionization detectors with sensitivities as low as 100 eVee (electron-equivalent energy) open new windows for studies on neutrino and dark matter physics. The relevant physics subjects are summarized. The detectors have to measure…
We present the noise performance of High Electron Mobility Transistors (HEMT) developed by CNRS-C2N laboratory. Various HEMT's gate geometries with 2 pF to 230 pF input capacitance have been studied at 4 K. A model for both voltage and…
The first operational prototype of a high-purity Germanium (HPGe) detector developed within the European LEAPS-INNOV project is presented in this work. This prototype features a monolithic, multi-element sensor optimized for high-resolution…
This study investigates new technology for enhancing the sensitivity of low-mass dark matter detection by analyzing charge transport in a p-type germanium detector at 5.2 K. To achieve low-threshold detectors, precise calculations of the…
$P$-type high-purity germanium (HPGe) detectors are widely used across many scientific domains, and current data analysis methods have served well in many use cases. However, applications like low-background experiments that search for rare…
Large, high-purity, germanium (HPGe) detectors are needed for neutrinoless double-beta decay and dark matter experiments. Currently, large (> 4 inches in diameter) HPGe crystals can be grown at the University of South Dakota (USD). We…
A new ultra low-level counting setup has been installed in the shallow-underground laboratory Felsenkeller in Dresden, Germany. It includes a high-purity germanium detector (HPGe) of 163\% relative efficiency within passive and active…
Searches for new physics push experiments to look for increasingly rare interactions. As a result, detectors require increasing sensitivity and specificity, and materials must be screened for naturally occurring, background-producing…
An electrically cooled Broad Energy Germanium (BEGe) detector has been characterized in the energy range E$_{\gamma}$ $\sim$ 0.122 - 7 MeV by utilizing the $\gamma$- rays emitted by a short-lived resonance state in $^{15}$O populated…
The direct detection of MeV-scale dark matter (DM) particles hinges on achieving an exceptionally low energy detection threshold. Germanium (Ge) detectors, meticulously tailored with precise impurity compositions, hold the potential to…
The detection of low-energy deposition in the range of sub-eV through ionization using germanium (Ge) with a bandgap of $\sim$0.7 eV requires internal amplification of charge signal. This can be achieved through high electric field which…
High-purity germanium (HPGe) crystals are required to be well-characterized before being fabricated into Ge detectors. The characterization of HPGe crystals is often performed with the Hall Effect system, which measures the carrier…
Radiation detectors constructed from large volume high purity Ge (HPGe) single crystals are widely used for gamma-ray spectroscopy. The detectors for this application can be simple in that they need only have two electrical contacts for…
A study of signals originating near the lithium-diffused n+ contact of p-type point contact (PPC) high purity germanium detectors (HPGe) is presented. The transition region between the active germanium and the fully dead layer of the n+…
Highly coherent mechanical resonators are invaluable to ultrasensitive detection techniques by enabling detection of small forces. Studying mechanical resonators in a thermal equilibrium state at millikelvin temperatures provides a…
High-purity germanium detectors are well suited to analysis the radioactivity of samples. In order to reduce the environmental background, low-activity lead and oxygen free copper are installed outside of the probe to shield gammas, outmost…
In this work we present the characterization of a Broad Energy Germanium (BEGe) type High Purity Germanium (HPGe) detector, with a carbon fiber entrance window thickness of 0.6 mm and an active area of 6305 mm2, operated at shallow depth (~…