Related papers: Reaction natYb+48Ca->217Th+3n: auto calibration pr…
Recently, in the DGFRS related experiments the discoveries of new superheavy elements 114 to 118 were successfully performed. As concerns to a background radical suppression in those experiments it was namely Active correlations method…
General philosophy of procedure of detecting rare events in the recent experiments with 48Ca projectile at the Dubna Gas-Filled Recoil Separator(DGFRS) aimed to the synthesis of superheavy elements (SHE) has been reviewed. Specific…
In this paper, we present the results of the first beam tests of the detection system at the focal plane of the Dubna Gas-Filled Recoil Separator-2 (DGFRS-2), which receives beams from the DC-280 FLNR cyclotron. The high beam intensity of…
Method of active correlations is a key one to suppress radically beam associated backgrounds in heavy ion induced complete fusion nuclear reactions. This property is enhanced significantly when applying DSSSD detector instead of position…
The Dubna Gas Filled Recoil Separator is the most advanced facility currently in use in the field of research of superheavy nuclei. Definitely, the DGFRS detection system and method of active correlations have played a significant role in…
PC-based one-crate monitoring and control system of the Dubna Gas Filled Recoil Separator (DGFRS) is considered. It is developed for the long-term experiments at the U400 FLNR cyclotron and is aimed at the synthesis of super heavy nuclei in…
Real-time PC based algorithm is developed for DSSSD ( Double Side Silicon Strip Detector) detector. Brief description of the detection system is also presented. Complete fusion nuclear reaction natYb+48Ca->217Th is used to test this…
With reaching to extremely high intensities of heavy-ion beams new requirements for the detection system of the Dubna Gas-Filled Recoil Separator (DGFRS) will definitely be set. One of the challenges is how to apply the active correlations…
Real-time PC based algorithm is developed for DSSSD detector. Complete fusion nuclear reaction natYb+48Ca->217Th is used to test this algorithm at 48Ca beam. Example of successful application of a former algorithm for resistive strip PIPS…
New approach to the life time estimation for recoil alpha detected times is presented. Brief description of the Dubna Gas Filled Recoil Separator detection module is presented too. This approach will be used for real time detecting ctive…
Detection system and software package coded in Builder C ++ are developed for the new analog spectrometer of the DGFRS-2 setup installed on the new DC-280 cyclotron. This software allows providing data acquisition using a 48x128 DSSSD…
Strongly correlated systems containing d/f-electrons present a challenge to conventional density functional theory (DFT), such as the widely used local density approximation (LDA) or generalized gradient approximation (GGA). In this work,…
Detecting the topology and direction of low-energy nuclear and electronic recoils is broadly desirable in nuclear and particle physics, with applications in coherent elastic neutrino-nucleus scattering, astrophysical neutrino measurements,…
An improved method of energy calibration of position-sensitive silicon detector is presented. Instead of the parabolic function used in traditional method, a new function describing the relation of position and energy is introduced and…
The goal of this thesis was to develop a procedure to optimize the mirror suppression, which reduces the dynamic range of the Fast Fourier Transform spectrometers (FFTS), and implement this procedure in the Field Programmable Gate Array…
A method for the calibration of a Silicon Position Sensitive Detector is described. From the combination of the signals collected at the ends of the resistive electrode, energy and angle of the hitting particle are reconstructed with a…
Spectroscopic investigations provide important insights into the composition of luminescence emissions relevant to trapped-charge dating of sediments. Accurate wavelength calibration and a correction for the wavelength-dependent detection…
We present an efficient implementation of periodic Gaussian density fitting (GDF) using the Coulomb metric. The three-center integrals are divided into two parts by range-separating the Coulomb kernel, with the short-range part evaluated in…
A new wide-range formula $T_\alpha =f (Q_\alpha)$ to operate with the new DGFRS2 analog spectrometer installed at the DC-280 cyclotron facility is presented. The main goal of this formula application algorithm is to search the optimal time…
This study introduces a novel self-supervised learning approach for volumetric segmentation of defect indications captured by phased array ultrasonic testing data from Carbon Fiber Reinforced Polymers (CFRPs). By employing this…