A method for the calibration of a Silicon Position Sensitive Detector is described. From the combination of the signals collected at the ends of the resistive electrode, energy and angle of the hitting particle are reconstructed with a procedure which straightforwardly accounts for different amplifier chain gains and dc offset effects.