The Compton camera is a gamma-ray imaging device developed in the 1970s. In the 1990s, the COMPTEL detector onboard the CGRO was the first to utilize a Compton camera for MeV all-sky survey observations. Recently, various Compton cameras…

We demonstrate a neutron tomography technique with sub-micrometer spatial resolution. Our method consists of measuring neutron diffraction spectra using a double crystal diffractometer as a function of sample rotation and then using a phase…

Instrumentation and Detectors · Physics 2020-11-13 B. Heacock , D. Sarenac , D. G. Cory , M. G. Huber , J. P. W. MacLean , H. Miao , H. Wen , D. A. Pushin

Angular filter refractometry is an optical diagnostic that measures absolute contours of line-integrated density gradient by placing a filter with alternating opaque and transparent zones in the focal plane of a probe beam, which produce…

Plasma Physics · Physics 2023-11-30 P. V. Heuer , D. Haberberger , S. T. Ivancic , C. A. Walsh , J. R. Davies

Many applications seek to measure a sample's absorption coefficient spectrum to retrieve the chemical makeup. Many real world samples are optically turbid, causing scattering confounds which many commercial spectrometers cannot address.…

Optics · Physics 2023-01-05 Giles Blaney , Angelo Sassaroli , Sergio Fantini

Serial section electron microscopy (ssEM) is a widely used technique for obtaining volumetric information of biological tissues at nanometer scale. However, accurate 3D reconstructions of identified cellular structures and volumetric…

Image and Video Processing · Electrical Eng. & Systems 2020-02-06 Thanuja D. Ambegoda , Julien N. P. Martel , Jozef Adamcik , Matthew Cook , Richard H. R. Hahnloser

Ultrafast imaging is essential in physics and chemistry to investigate the femtosecond dynamics of nonuniform samples or of phenomena with strong spatial variations. It relies on observing the phenomena induced by an ultrashort laser pump…

Optics · Physics 2021-02-11 Chen Xie , Remi Meyer , Luc Froehly , Remo Giust , Francois Courvoisier

In optical imaging, achieving high resolution often comes at the expense of a shallow depth of field. This means that when using a standard microscope, any minor movement of the object along the optical axis can cause the image to become…

Coded apertures, traditionally employed in x-ray astronomy for imaging celestial objects, are now being adapted for micro-scale applications, particularly in studying microscopic specimens with synchrotron light diffraction. In this paper,…

Signal Processing · Electrical Eng. & Systems 2024-05-22 Doğa Gürsoy , Dina Sheyfer , Michael Wojcik , Wenjun Liu , Jonathan Tischler

The applicability of standard methods for compositional analysis is limited for H-containing films. Neutron reflectometry is a powerful, non-destructive method that is especially suitable for these systems due to the large negative…

In this paper, we introduce a novel artificial neural network (ANN) based scheme to estimate the thickness of thin films deposited on a given substrate. Here we consider the visible interference pattern between a plane wave and a diverging…

Machine Learning · Computer Science 2022-10-21 Archana Bora

A method of the mid-IR-laser microscopy has been proposed for the investigation of the large-scale electrically and recombination active defects in semiconductors and non-destructive inspection of semiconductor materials and structures in…

Materials Science · Physics 2011-05-17 V. P. Kalinushkin , V. A. Yuryev , O. V. Astafiev

The optics of a number of future X-ray telescopes will have very long focal lengths (10 - 20 m), and will consist of a number of nested/stacked thin, grazing-incidence mirrors. The optical quality characterization of a real mirror can be…

Instrumentation and Methods for Astrophysics · Physics 2015-09-09 D. Spiga , S. Basso , M. Bavdaz , V. Burwitz , M. Civitani , O. Citterio , M. Ghigo , G. Hartner , B. Menz , G. Pareschi , L. Proserpio , B. Salmaso , G. Tagliaferri , E. Wille

Muon Scattering Tomography (MST) is a promising non-invasive inspection technique, yet the practical application of short-time MST is hindered by poor image quality due to limited muon flux. To address this limitation, we propose a…

Image and Video Processing · Electrical Eng. & Systems 2026-02-10 Haochen Wang , Pei Yu , Liangwen Chen , Weibo He , Yu Zhang , Yuhong Yu , Xueheng Zhang , Lei Yang , Zhiyu Sun

Thin film interferometry is a powerful technique for non-invasively measuring liquid film thickness with applications in ophthalmology, but its clinical translation is hindered by the challenges in reconstructing thickness profiles from…

Computer Vision and Pattern Recognition · Computer Science 2025-10-30 Gautam A. Viruthagiri , Arnuv Tandon , Gerald G. Fuller , Vinny Chandran Suja

DeepAngle is a machine learning-based method to determine the contact angles of different phases in the tomography images of porous materials. Measurement of angles in 3--D needs to be done within the surface perpendicular to the angle…

Computer Vision and Pattern Recognition · Computer Science 2022-11-29 Arash Rabbani , Chenhao Sun , Masoud Babaei , Vahid J. Niasar , Ryan T. Armstrong , Peyman Mostaghimi

A method of using X-ray absorption spectroscopy (XAS) together with resolved grazing incidence geometry for depth profiling atomic, electronic, chemical or magnetic local structures in thin films is presented. The quantitative deconvolution…

As demand for advanced photographic applications on hand-held devices grows, these electronics require the capture of high quality depth. However, under low-light conditions, most devices still suffer from low imaging quality and inaccurate…

Computer Vision and Pattern Recognition · Computer Science 2018-03-22 Sunghoon Im , Hae-Gon Jeon , In So Kweon

In this contribution, we explore the imaging limits of terahertz single-pixel cameras and present a way to improve the achievable signal-to-noise ratio and spatial resolution using a technique called dithering masks. The proposed procedure…

Instrumentation and Detectors · Physics 2017-11-10 Sven Augustin , Tom Szollmann , Peter Jung , Heinz-Wilhelm Huebers

Transducers with larger aperture size are desirable in ultrasound imaging to improve resolution and image quality. A coherent multi-transducer ultrasound imaging system (CoMTUS) enables an extended effective aperture through coherent…

We investigate the growth conditions for thin (less than 200 nm) sputtered aluminum (Al) films. These coatings are needed for various applications, e.g. for advanced manufacturing processes in the aerospace industry or for nanostructures…