English
Related papers

Related papers: ANAIS: Status and prospects

200 papers

COSINE-200 is the next phase of the ongoing COSINE-100 experiment. The main purpose of the experiment is the performance of an unambiguous verification of the annual modulation signals observed by the DAMA experiment. The success of the…

Instrumentation and Detectors · Physics 2020-07-27 Keonah Shin , Junseok Choe , Olga Gileva , Alain Iltis , Yeongduk Kim , Cheolho Lee , Hyun Su Lee , Moo Hyun Lee , Hyang Kyu Park

We present here the model dependent and independent sensitivity studies for NaI detectors designed to test the DAMA result, and compare the predicted limits from SABRE with the present performance of both ANAIS and COSINE. We find that the…

High Energy Physics - Experiment · Physics 2022-12-28 Madeleine J. Zurowski , Elisabetta Barberio

The SABRE (Sodium Iodide with Active Background Rejection) experiment will search for an annually modulating signal from dark matter particles in our Galaxy using an array of ultra-pure NaI(Tl) detectors surrounded by an active scintillator…

Instrumentation and Detectors · Physics 2018-07-24 Paolo Montini

The present DAMA/LIBRA experiment and the former DAMA/NaI have cumulatively released so far the results obtained with the data collected over 13 annual cycles (total exposure: 1.17 ton $\times$ yr). They give a model independent evidence of…

Cosmology and Nongalactic Astrophysics · Physics 2010-07-06 R. Bernabei , P. Belli , F. Cappella , R. Cerulli , C. J. Dai , A. d'Angelo , H. L. He , A. Incicchitti , X. H. Ma , F. Montecchia , F. Nozzoli , D. Prosperi , X. D. Sheng , Z. P. Ye , R. G. Wang

DTAS is a segmented total absorption {\gamma}-ray spectrometer developed for the DESPEC experiment at FAIR. It is composed of up to eighteen NaI(Tl) crystals. In this work we study the performance of this detector with laboratory sources…

We report recent results of a WIMP dark matter search experiment using 310g of CaF2(Eu) scintillator at Kamioka Observatory. We chose a highly radio-pure crystal, PMTs and radiation shields, so that the background rate decreased…

Astrophysics · Physics 2008-11-26 Y. Shimizu , M. Minowa , W. Suganuma , Y. Inoue

The DAMA experiment's long-standing claim of dark matter detection remains a key open issue in astroparticle physics. Independent verification requires NaI(Tl)-based detectors with enhanced low-energy sensitivity. Current detectors rely on…

This note, with its five questions, is intended to contribute to a clarification about a claimed "evidence" by the DAMA group of an annual modulation of the counting rate of a Dark Matter NaI(Tl) detector as due to a neutralino (SUSY-LSP)…

Astrophysics · Physics 2007-05-23 G. Gerbier , J. Mallet , L. Mosca , C. Tao

Weakly Interacting Massive Particles (WIMP) are possible components of the Universe's Dark Matter. The detection of WIMP is signalled by the recoil of the atomic nuclei which form a detector. CoGeNT at the Soudan Underground Laboratory…

Cosmology and Nongalactic Astrophysics · Physics 2016-12-21 O. Civitarese , K. J. Fushimi , M. E. Mosquera

The cosmogenic production of long-lived radioactive isotopes in materials is an hazard for experiments demanding ultra-low background conditions. Although NaI(Tl) scintillators have been used in this context for a long time, very few…

Data collected during three years with a germanium spectrometer at the Sierra Grande underground laboratory have been analyzed for distinctive features of annual modulation of the signal induced by WIMP dark matter candidates. The main…

We present a comprehensive study of the nonproportionality of NaI(Tl) scintillation detectors within the context of dark matter search experiments. Our investigation, which integrates COSINE-100 data with supplementary $\gamma$…

The DAMA experiment using ultra low background NaI(Tl) crystal scintillators has measured an annual modulation effect in the keV region which satisfies all the peculiarities of an effect induced by Dark Matter particles. In this paper we…

High Energy Physics - Experiment · Physics 2018-12-21 R. Cerulli , P. Villar , F. Cappella , R. Bernabei , P. Belli , A. Incicchitti , A. Addazi , Z. Berezhiani

The DAMA/LIBRA-phase1 and the former DAMA/NaI data (cumulative exposure 1.33 ton $\times$ yr, corresponding to 14 annual cycles) give evidence at 9.3 $\sigma$ C.L. for the presence of Dark Matter (DM) particles in the galactic halo, on the…

Cosmology and Nongalactic Astrophysics · Physics 2014-12-23 R. Bernabei

For many years annually modulating $\sim$ keV scintillations have been observed in the DAMA/NaI and DAMA/Libra experiments. A dark matter - electron scattering interpretation is now favoured given the stringent constraints on nuclear recoil…

High Energy Physics - Phenomenology · Physics 2016-07-01 R. Foot

Scintillation characteristics of a thallium doped sodium iodide (NaI(Tl)) crystal with a dimension of 0.6 x 0.6 x 2 cm3 are studied by attaching a silicon photomultiplier (SiPM) direct to the crystal over a temperature range from 93 to 300…

Instrumentation and Detectors · Physics 2022-03-02 H. Y. Lee , J. A. Jeon , K. W. Kim , W. K. Kim , H. S. Lee , M. H. Lee

Scintillating crystal detector may offer some potential advantages in the low-energy, low-background experiments. A 500 kg CsI(Tl) detector to be placed near the core of Nuclear Power Station II in Taiwan is being constructed for the…

High Energy Physics - Experiment · Physics 2012-08-27 TEXONO Collaboration

Thallium-doped sodium iodide (NaI(Tl)) scintillation detectors play an important role in the field of direct dark matter (DM) searches. The DAMA/LIBRA experiment stands out for its reported observation of an annually modulating DM-like…

COSINE-100 is a dark matter direct detection experiment designed to test the annual modulation signal observed by the DAMA/LIBRA experiment. COSINE-100 consists of 8 NaI(Tl) crystals with a total mass of 106 kg, a 2200 L liquid scintillator…

The most discussed topic in direct search for dark matter is arguably the verification of the DAMA claim. In fact, the observed annual modulation of the signal rate in an array of NaI(Tl) detectors can be interpreted as the awaited…

‹ Prev 1 4 5 6 7 8 10 Next ›