English
Related papers

Related papers: On the calibration of direct-current current trans…

200 papers

The method for controlling a DC-DC converter is proposed to ensures the high quality control at large fluctuations in load currents by using differential gain control coefficients and second derivative control. Various implementations of…

Systems and Control · Electrical Eng. & Systems 2024-08-13 Alexander Domyshev , Elena Chistyakova , Aliona Dreglea , Denis Sidorov , Fang Liu

We present the comparison of results from the generation and the measurement of direct currents in the pA range, performed with traceable state-of-the-art methods at highest accuracy. The currents were generated with the capacitor charging…

Other Condensed Matter · Physics 2016-11-17 Hansjörg Scherer , Gerd-Dietmar Willenberg , Dietmar Drung , Martin Götz , Eckart Pesel

Three-phase AC-DC rectifiers are fundamental components in modern power electronics systems, yet achieving rapid voltage regulation and precise current tracking under load and grid disturbances remains challenging due to nonlinear dynamics…

Optimization and Control · Mathematics 2026-03-02 Koto Omiloli , Satish Vedula , Ayobami Olajube , Olugbenga Moses Anubi

The recent advances in power plants and energy resources have extended the applications of DC-DC converters in the power systems (especially in the context of DC micro-grids). Parameter identification can extract the parameters of the…

Systems and Control · Electrical Eng. & Systems 2021-09-09 Seyyed Rashid Khazeiynasab , Issa Batarseh

An interlaboratory comparison of small-current generation and measurement capability is presented with the ultrastable low-noise current amplifier (ULCA) acting as travelling standard. Various measurements at direct currents between 0.16 nA…

We detail the calibration of the D-dot probes used on the Los Alamos National Laboratory DARHT Axis 1 LIA compensation cans (CCs). We hope this will serve not only as a record of this calibration, but also as a guide on how to perform…

Accelerator Physics · Physics 2017-10-25 J. Martin Taccetti , Darin Westley , Jeffrey B. Johnson , Paul Flores

Nanoscale single-electron pumps can be used to generate accurate currents, and can potentially serve to realize a new standard of electrical current based on elementary charge. Here, we use a silicon-based quantum dot with tunable tunnel…

Mesoscale and Nanoscale Physics · Physics 2014-06-26 A. Rossi , T. Tanttu , K. Y. Tan , I. Iisakka , R. Zhao , K. W. Chan , G. C. Tettamanzi , S. Rogge , A. S. Dzurak , M. Möttönen

Large high field superconducting magnets often requires high current superconducting cables. In order to develop these cables, a facility capable of providing high magnetic field with large sampling area as well as electrical current of…

Superconductivity · Physics 2023-02-16 Hui Yu , Jeremy Levitan , Jun Lu

A family of interleaved current-fed high step-up dc-dc converters are introduced and analyzed here by combining a voltage multiplier (VM) and an active clamp circuit for high-voltage high-power applications. Low input currents and output…

Systems and Control · Electrical Eng. & Systems 2023-05-30 R. Beiranvand , S. H. Sangani

This manuscript describes a radiation-hardened current-mode delta-sigma ADC fabricated in a standard 130 nm CMOS technology and qualified for total ionizing doses up to 100 Mrad. The operational signal range achieved with a 100 s…

Instrumentation and Detectors · Physics 2026-03-05 Luca Giangrande

The high frequency primary power standard is univocally realized by means of a coaxial microcalorimeter, at least up to 40 GHz. The coaxial microcalorimeter is a broadband measurement system adjusted for effec-tive efficiency measurement of…

Instrumentation and Detectors · Physics 2021-03-09 Luciano Brunetti , Luca Oberto , Marco Sellone

Using standard microfabrication techniques it is now possible to construct devices, which appear to reliably manipulate electrons one at a time. These devices have potential use as building blocks in quantum computing devices, or as a…

Mesoscale and Nanoscale Physics · Physics 2014-11-20 S. P. Giblin , S. J. Wright , J. Fletcher , M. Kataoka , M. Pepper , T. J. B. M. Janssen , D. A. Ritchie , C. A. Nicoll , D. Anderson , G. A. C. Jones

We broach a seldom-discussed topic in precision metrology; how subtle errors in calibration processes are discovered and remedied. We examine a case study at the National Physical Laboratory (NPL), UK, involving the calibration of DC…

Instrumentation and Detectors · Physics 2025-12-03 Stephen Giblin

The paper considers the calibration of control-bounded analog-to-digital converters. It is demonstrated that variations of the analog frontend can be addressed by calibrating the digital estimation filter. In simulations (both behavioral…

Systems and Control · Electrical Eng. & Systems 2023-11-15 Hampus Malmberg , Till Mettler , Thomas Burger , Fredrik Feyling , Hans-Andrea Loeliger

AC power cycling tests allow the most realistic reliability assessment by applying close to real stress to the device or module under test to meet functional safety standards, which is highly critical for traction applications. This paper…

Systems and Control · Electrical Eng. & Systems 2023-07-20 Masoud Farhadi , Bhanu Teja Vankayalapati , Rahman Sajadi , Bilal Akin

The increasing penetration of renewables is replacing traditional synchronous generation in modern power systems with low-inertia asynchronous converter-interfaced generators (CIGs). This penetration threatens the dynamic stability of the…

Systems and Control · Electrical Eng. & Systems 2025-03-18 Xuezao Wang , Yijun Xu , Wei Gu , Kai Liu , Shuai Lu , Mert Korkali , Lamine Mili

A single-contact voltage sensor designed for accurate measurements of ac voltages across a pair of conductors is described. The sensor design is motivated by remote monitoring applications where accurate voltage measurement of high-voltage…

Instrumentation and Detectors · Physics 2020-06-29 Jake S. Bobowski , Saimoom Ferdous , Thomas Johnson

Procedures and results on hardware level detector calibration in Super-Kamiokande (SK) are presented in this paper. In particular, we report improvements made in our calibration methods for the experimental phase IV in which new readout…

Instrumentation and Detectors · Physics 2013-12-23 K. Abe , Y. Hayato , T. Iida , K. Iyogi , J. Kameda , Y. Kishimoto , Y. Koshio , Ll. Marti , M. Miura , S. Moriyama , M. Nakahata , Y. Nakano , S. Nakayama , Y. Obayashi , H. Sekiya , M. Shiozawa , Y. Suzuki , A. Takeda , Y. Takenaga , H. Tanaka , T. Tomura , K. Ueno , R. A. Wendell , T. Yokozawa , T. J. Irvine , H. Kaji , T. Kajita , K. Kaneyuki , K. P. Lee , Y. Nishimura , K. Okumura , T. McLachlan , L. Labarga , E. Kearns , J. L. Raaf , J. L. Stone , L. R. Sulak , S. Berkman , H. A. Tanaka , S. Tobayama , M. Goldhaber , K. Bays , G. Carminati , W. R. Kropp , S. Mine , A. Renshaw , M. B. Smy , H. W. Sobel , K. S. Ganezer , J. Hill , W. E. Keig , J. S. Jang , J. Y. Kim , I. T. Lim , N. Hong , T. Akiri , J. B. Albert , A. Himmel , K. Scholberg , C. W. Walter , T. Wongjirad , T. Ishizuka , S. Tasaka , J. G. Learned , S. Matsuno , S. N. Smith , T. Hasegawa , T. Ishida , T. Ishii , T. Kobayashi , T. Nakadaira , K. Nakamura , K. Nishikawa , Y. Oyama , K. Sakashita , T. Sekiguchi , T. Tsukamoto , A. T. Suzuki , Y. Takeuchi , K. Huang , K. Ieki , M. Ikeda , T. Kikawa , H. Kubo , A. Minamino , A. Murakami , T. Nakaya , M. Otani , K. Suzuki , S. Takahashi , Y. Fukuda , K. Choi , Y. Itow , G. Mitsuka , M. Miyake , P. Mijakowski , R. Tacik , J. Hignight , J. Imber , C. K. Jung , I. Taylor , C. Yanagisawa , Y. Idehara , H. Ishino , A. Kibayashi , T. Mori , M. Sakuda , R. Yamaguchi , T. Yano , Y. Kuno , S. B. Kim , B. S. Yang , H. Okazawa , Y. Choi , K. Nishijima , M. Koshiba , Y. Totsuka , M. Yokoyama , K. Martens , M. R. Vagins , J. F. Martin , P. de Perio , A. Konaka , M. J. Wilking , S. Chen , Y. Heng , H. Sui , Z. Yang , H. Zhang , Y. Zhenwei , K. Connolly , M. Dziomba , R. J. Wilkes

Scintillator detectors electronics is recalibrated against the datasheet given by the manufacturer. Optimal and mutual dependent values of (a) high voltage at PMT (Photomultiplier Tube), (b) amplifier gain, (c) average time to count the…

Instrumentation and Detectors · Physics 2023-03-07 Mayank Goswami , Kajal Kumari

We describe the design, operation, and first results of a photometric calibration project, called DICE (Direct Illumination Calibration Experiment), aiming at achieving precise instrumental calibration of optical telescopes. The heart of…