English
Related papers

Related papers: Development of Multi-gap Resistive Plate Chamber (…

200 papers

The low cost and high resolution gas-based Multi-gap Resistive Plate Chamber (MRPC) opens a new possibility to find an efficient alternative detector for Time of Flight (TOF) based Positron Emission Tomography, where the sensitivity of the…

Instrumentation and Detectors · Physics 2011-06-30 A. Banerjee , S. Chattopadhyay

The Multi-gap Resistive Plate Chamber (MRPC) is an advanced form of Resistive Plate Chamber (RPC) detector where the gas gap is divided into sub-gaps. MRPCs are known for their good time resolution and detection efficiency for charged…

Instrumentation and Detectors · Physics 2018-08-15 Rajesh Ganai , Mitali Mondal , Shaifali Mehta , Zubayer Ahammed , Subhasis Chattopadhyay

The Multigap Resistive Plate Chambers (MRPCs) provide excellent timing as well as position resolutions at relatively low cost. Therefore, they can be used in medical imaging applications such as PET where precise timing is a crucial…

Instrumentation and Detectors · Physics 2019-07-23 M. Nizam , B. Satyanarayana , R. R. Shinde , G. Majumder

The Multigap Resistive Plate Chambers (MRPCs) are gas ionization detectors with multiple gas sub-gaps made of resistive electrodes. The high voltage (HV) is applied on the outer surfaces of outermost resistive plates only, while the…

Instrumentation and Detectors · Physics 2016-12-16 Moon Moon Devi , Naba K. Mondal , B. Satyanarayana , R. R. Shinde

Time-Of-Flight (TOF) is a noble technique that is used in Positron Emission Tomography (PET) imaging worldwide. The scintillator based imaging system that is being used around the world for TOF-PET is very expensive. Multi-gap Resistive…

Instrumentation and Detectors · Physics 2018-07-02 Rajesh Ganai , Shaifali Mehta , Mehulkumar Shiroya , Mitali Mondal , Zubayer Ahammed , Subhasis Chattopadhyay

In this work we describe some recent results concerning the application of Resistive Plate Chambers operated in avalanche mode at atmospheric pressure for high-resolution time-of-flight measurements. A combination of multiple, mechanically…

Instrumentation and Detectors · Physics 2009-11-07 P. Fonte , V. Peskov

Multi-gap Resistive Plate Chamber(MRPC) is a widely used timing detector with a typical time resolution of about 60 ps. This makes MRPC an optimal choice for the time of flight(ToF) system in many large physics experiments. The prior work…

Instrumentation and Detectors · Physics 2019-09-04 Fuyue Wang , Dong Han , Yi Wang , Yancheng Yu , Baohong Guo , Yuanjing Li

Multi-gap Resistive Plate Chambers (MRPCs) with multi-strip readout are considered to be the optimal detector candidate for the Time-of-Flight (ToF) wall in the Compressed Baryonic Matter (CBM) experiment. In the R&D phase MRPCs with…

Instrumentation and Detectors · Physics 2016-11-23 I. Deppner , N. Herrmann , J. Frühauf , M. Kiš , P. Lyu , P. -A. Loizeau , L. Shi , C. Simon , Y. Wang , B. Xie

In order to test the performance of detector/prototype in environment of laboratory, we design and build a larger area ($90\times52$ $cm^2$) test platform of cosmic ray based on well-designed Multi-gap Resistive Plate Chamber (MRPC) with an…

Instrumentation and Detectors · Physics 2015-03-16 Tianxiang Chen , Cheng Li , Yongjie Sun , Hongfang Chen , Ming Shao , Zebo Tang , Rongxing Yang , Yi Zhou , Yifei Zhang

A new kind of Multi-gap Resistive Plate Chamber (MRPC) has been built for the large-area Muon Telescope Detector (MTD) for the STAR experiment at RHIC. These long read-out strip MRPCs (LMRPCs) have an active area of 87.0 x 17.0 cm2 and ten…

The Multigap Resistive Plate Chamber (MRPC) is a gaseous detector; the performance depends very much on the gas mixture as well as the design. MRPCs are used as a timing device in several collider experiments and cosmic ray experiments…

Instrumentation and Detectors · Physics 2019-03-27 Yongwook Baek , Dowon Kim , M. C. S. Williams

The Resistive Plate Chambers (RPC) are low-cost charged-particle detectors with good timing resolution and potentially good spatial resolution. Using RPC as gamma detector provides an opportunity for application in positron emission…

Instrumentation and Detectors · Physics 2014-02-20 Zhou Weizheng , Shao Ming , Li Cheng , Chen Hongfang , Sun Yongjie , Chen Tianxiang

In the CBM (Compressed Baryonic Matter) experiment constructed at the Facility for Anti-proton and Ion Research (Fair) at GSI, Darmstadt, Germany, MRPC(Multi-gap Resistive Plate Chamber) is adopted to construct the large TOF…

A new prototype of large area Multi-gap Resistive Plate Chamber (MRPC) with long readout strips was built. This Long-strip Multi-gap Resistive Plate Chamber (LMRPC) is double stacked and has ten 250 $\mu$m-thick gas gaps. Signals are read…

Instrumentation and Detectors · Physics 2015-05-20 Yongjie sun , Cheng Li , Zebo Tang , Lailin Xu , Tianxiang Chen , Ming Shao

Resistive Plate Chamber (RPC) is a gaseous detector, known for its good spatial resolution and excellent time resolution. Due to its fast response and excellent time resolution, it is used for both triggering and timing purpose. But the…

Instrumentation and Detectors · Physics 2022-10-26 Jaydeep Datta , Nayana Majumdar , Supratik Mukhopadhyay , Sandip Sarkar

The time resolution of Multigap Resistive Plate Counters (MRPCs) to $511$ keV gamma rays has been investigated using a $^{22}$Na source and four detectors. The MRPCs time resolution has been derived from the Time-of-Flight information,…

Instrumentation and Detectors · Physics 2015-12-09 G. Belli , M. Gabusi , G. Musitelli , R. Nardò , S. P. Ratti , A. Tamborini , P. Vitulo

A prototype of Multi-strip Multi-gap Resistive Plate chamber (MMRPC) with active area 40 cm $\times$ 20 cm has been developed at SINP, Kolkata. Detailed response of the developed detector was studied with the pulsed electron beam from ELBE…

We have developed multi-gap resistive plate chambers (MRPCs) with 2.5 x 200 cm2 readout strips for the time-of-flight (TOF) detector system of the LEPS2 experiment at SPring-8. These chambers consist of 2 stacks and 5 gas gaps per stack, in…

Principles of operation, construction and first test results of a Dielectric Resistive Plate Chamber (DRPC) are described. The detector has shown stability of operation in the avalanche mode of gas amplfication within a wide range of…

Instrumentation and Detectors · Physics 2007-05-23 A. Akindinov , V. Golovin , A. Martemiyanov , V. Petrov , A. Smirnitskiy , K. Voloshin

Muography is finding applications in various domains such as volcanology, archaeology, civil engineering, industry, mining, and nuclear waste surveys. To simplify transportation and installation in remote locations after laboratory testing,…