Related papers: First results with a microcavity plasma panel dete…
The high-luminosity upgrade of the CERN LHC requires the replacement of the CMS tracking detector to cope with the increased radiation fluence while maintaining its excellent performance. An extensive R\&D program, aiming at using 3D pixel…
We present an innovative charge detector with high resolution and wide dynamic range designed to fulfill the requirements of a monitoring system for a high energy ion beam. The detector prototype, constructed using Si photodiodes and a…
The epitaxial growth of two-dimensional (2D) $\beta-In_2Se_3$ material was obtained over 2-inches c-sapphire wafers using molecular beam epitaxy (MBE). Excellent quality of thick (90 nm) and very thin films, down to two quintuple layers (2…
This paper describes the performance of a prototype timing detector, based on 50 micrometer thick Ultra Fast Silicon Detector, as measured in a beam test using a 180 GeV/c momentum pion beam. The dependence of the time precision on the…
Optical excitation and subsequent decay of graphene plasmons can produce a significant increase in charge-carrier temperature. An efficient method to convert this temperature elevation into a measurable electrical signal at room temperature…
We propose a detector of microwave photons which can distinguish the vacuum state, one-photon state, and the states with two or more photons. Its operation is based on the two-photon transition in a biased Josephson junction and detection…
A simple table-size ECR plasma generator operates in the ATOMKI without axial magnetic trap and without any particle extraction tool. Radial plasma confinement is ensured by a NdFeB hexapole. The table-top ECR is a simplified version of the…
Photodetectors are key optoelectronic building blocks performing the essential optical-to-electrical signal conversion, and unlike solar cells, operate at a specific wavelength and at high signal or sensory speeds. Towards achieving high…
The paper summarizes our latest progress in the development of newly introduced micro pattern gaseous detectors with resistive electrodes. These resistive electrodes protect the detector and the front-end electronics in case of occasional…
Nonlinear frequency conversion provides an elegant method to detect photons in a spectral range which differs from the pump wavelength, making it highly attractive for photons with inherently low energy. Aside from the intensity of the…
A liquid isooctane (C$_{8}$H$_{18}$) filled ionization linear array for radiotherapy quality assurance has been designed, built and tested. The detector consists of 128 pixels, each of them with an area of 1.7 mm $\times$ 1.7 mm and a gap…
This experimental particle-physics thesis reports the latest developments on the GasPM, a novel gaseous photodetector aimed at suppressing beam-induced backgrounds in the electromagnetic calorimeter for a potential upgrade of the Belle~II…
High-resolution 3D tracking with sub-nanosecond timing is required for the detection of elementary particles, such as neutrinos. Conventional detectors, which utilize analog silicon photomultipliers, face challenges in balancing spatial…
The MuPix7 is a prototype high voltage monolithic active pixel sensor with 103 times 80 um2 pixels thinned to 64 um and incorporating the complete read-out circuitry including a 1.25 Gbit/s differential data link. Using data taken at the…
We present the design of a Faraday cup-like charged particle detector in a four quadrant configuration aimed at facilitating the alignment of low-intensity beams of exotic particles. The device is capable of assessing the current on the…
We report new detailed density profile measurements in expanding strongly-coupled neutral plasmas. Using laser-induced fluorescence techniques, we determine plasma densities in the range of 10^5 to 10^9/cm^3 with a time resolution limit as…
Microwave reflectance probed photoconductivity (or $\mu$-PCD) measurement represents a contactless and non-invasive method to characterize impurity content in semiconductors. Major drawbacks of the method include a difficult separation of…
A systematic investigation of Planacon MCP-PMTs was performed using 64 XP85002/FIT-Q photosensors. These devices are equipped with microchannel plates of reduced resistance. Results of a study of their gain stability over time and…
Transition edge sensor microcalorimeters can measure x-ray and gamma-ray energies with very high energy resolution and high photon-collection efficiency. For this technology to reach its full potential in future x-ray observatories, each…
For the ATLAS Pixel Detector fast readout electronics has been successfully developed and tested. Main attention was given to the ability to detect small charges in the order of 5,000 electrons within 25 ns in the harsh radiation…