Related papers: First results with a microcavity plasma panel dete…
In-beam evaluation of a fully-equipped medium-size 30$\times$30 cm$^2$ Resistive Plate WELL (RPWELL) detector is presented. It consists here of a single element gas-avalanche multiplier with Semitron ESD225 resistive plate, 1 cm$^2$ readout…
We have developed MICROMEGAS (MICRO MEsh GASeous) detectors for detecting {\alpha} particles emitted from an 241-Am standard source. The voltage applied to the ionization region of the detector is optimized for stable operation at room…
This work aims to characterize ultra high dose rate pulses (UHDpulse) electron beams using the hybrid semiconductor pixel detector. The Timepix3 (TPX3) ASIC chip was used to measure the composition, spatial, time, and spectral…
We demonstrate laser-plasma acceleration of high charge electron beams to the ~10 MeV scale using ultrashort laser pulses with as little energy as 10 mJ. This result is made possible by an extremely dense and thin hydrogen gas jet. Total…
In this work we describe a parallel geometry gaseous detector constituted by a thin (0.6 mm) amplifying gap preceded by a drift region. The gap is delimited by a metal plate and by a wire mesh. The detector can count up to a rate of 10^7…
We report the discovery of gamma-ray pulsations from the nearby isolated millisecond pulsar PSR J0030+0451 with the Large Area Telescope (LAT) on the \emph{Fermi} Gamma-ray Space Telescope (formerly GLAST). This discovery makes PSR…
The plasma panel sensor is an ionizing photon and particle radiation detector derived from PDP technology with high gain and nanosecond response. Experimental results in detecting cosmic ray muons and beta particles from radioactive sources…
Large Area Picosecond PhotoDetectors (LAPPDs) are photosensors based on microchannel plate technology with about 400 cm$^2$ sensitive area. The external readout plane of a capacitively coupled LAPPD can be segmented into pads providing a…
A beam imaging detector was developed by coupling a multi-strip anode with delay line readout to an E$\times$B microchannel plate (MCP) detector. This detector is capable of measuring the incident position of the beam particles in…
In this work, Rayleigh microwave scattering was utilized to measure the electron number density produced by nanosecond high voltage breakdown in air between two electrodes in a pin-to-pin configuration (peak voltage 26 kV and pulse duration…
We have developed a prototype time-resolved neutron imaging detector employing a micro-pattern gaseous detector known as the micro-pixel chamber ({\mu}PIC) coupled with a field-programmable-gate-array-based data acquisition system. Our…
CMOS Monolithic Active Pixel Sensors (CPS) are ultra-light and highly granular silicon pixel detectors suited for highly sensitive charged particle tracking. Being manufactured with cost efficient standard CMOS processes, CPS may integrate…
The resistive-pulse technique provides a fast and label-free method for nanoparticle detection. In order to achieve a higher sensitivity, thin nanopores, such as silicon nitride pores, are usually considered. In this paper, nanoparticle…
An array of DEPFET pixels is one of several concepts to implement an active pixel sensor. Similar to PNCCD and SDD detectors, the typically 0.45 mm thick silicon sensor is fully depleted by the principle of sideward depletion. They have…
High speed camera imaging is a powerful tool to probe the spatiotemporal features of unsteady processes in plasmas, usually assuming light fluctuations to be a proxy for the plasma density fluctuations. In this article, we systematically…
In this study we report the results of a systematic study of the gain, rate and the position resolution limits of various micropattern gaseous detectors. It was found that at low rates (<1 Hz/mm^2) each detector has it own gain limit, which…
A MHz frame rate X-ray area detector (LPD - Large Pixel Detector) is under development by the Rutherford Appleton Laboratory for the European XFEL. The detector will have 1 million pixels and allows analogue storage of 512 images taken at…
The current state of the art in fast timing resolution for existing experiments is of the order of 100 ps on the time of arrival of both charged particles and electromagnetic showers. Current R&D on charged particle timing is approaching…
The micropattern gaseous detector Micromegas has been developed for several years in Saclay and presents good performance for neutron detection. A prototype for neutron imaging has been designed and new results obtained in thermal neutron…
Plasma scattering measurement is effective technique to observe low frequency density fluctuations excited in plasma. The spatial and wave number resolutions and the S/N ratio of measurement depend on the wavelength range, the size and the…