English
Related papers

Related papers: Traceable precision pA direct current measurements…

200 papers

We present the comparison of results from the generation and the measurement of direct currents in the pA range, performed with traceable state-of-the-art methods at highest accuracy. The currents were generated with the capacitor charging…

Other Condensed Matter · Physics 2016-11-17 Hansjörg Scherer , Gerd-Dietmar Willenberg , Dietmar Drung , Martin Götz , Eckart Pesel

We report on new calibration methods for picoammeters and low-current sources. The "Ultrastable Low-noise Current Amplifier" (ULCA) was used for the exemplary calibration of commercial state-of-the-art ammeter and current source instruments…

Instrumentation and Detectors · Physics 2016-03-24 Hansjörg Scherer , Dietmar Drung , Christian Krause

An interlaboratory comparison of small-current generation and measurement capability is presented with the ultrastable low-noise current amplifier (ULCA) acting as travelling standard. Various measurements at direct currents between 0.16 nA…

We performed calibrations of four different commercial picoammeters using the Ultrastable Low-noise Current Amplifier (ULCA) as a calibrator current source operated in the range between 1 femtoampere and 1 microampere. The results allow the…

Instrumentation and Detectors · Physics 2018-11-26 Hansjörg Scherer , Dietmar Drung , Christian Krause , Martin Götz , Ulrich Becker

An ultrastable low-noise current amplifier (ULCA) is presented. The ULCA is a non-cryogenic instrument based on specially designed operational amplifiers and resistor networks. It involves two stages, the first providing a 1000-fold current…

Instrumentation and Detectors · Physics 2014-08-22 Dietmar Drung , Christian Krause , Ulrich Becker , Hansjörg Scherer , Franz Josef Ahlers

An ultrastable low-noise current amplifier (ULCA) has been transferred between two laboratories, NPL and PTB, four times, with three of the transfers yielding a relative change in the trans-resistance gain of less than $2 \times 10^{-7}$.…

Instrumentation and Detectors · Physics 2019-03-08 Stephen Giblin , Dietmar Drung , Martin Goetz , Hansjoerg Scherer

In this paper, we present a programmable Ultra Low DC Current Source (ULCS) developed at T\"UB\.ITAK UME. The output current range is from 1 fA up to 100 pA with 100 aA resolution and is directly traceable to DC voltage, capacitance and…

Instrumentation and Detectors · Physics 2019-07-23 Omer Erkan , Yakup Gulmez , Cem Hayirli , Gulay Gulmez , Enis Turhan

The capacitance-charging method is a well-established and handy technique for the generation of dc current in the 100 pA range or lower. The method involves a capacitance standard and a sampling voltmeter, highly stable devices easy to…

Instrumentation and Detectors · Physics 2013-12-09 Luca Callegaro , Pier Paolo Capra , Vincenzo D'Elia , Flavio Galliana

New technology, the ultrastable low-noise current amplifier and the electron pump, provide new methods for making traceable measurements of small DC electric currents. We review four traceability routes for small current measurements and…

Instrumentation and Detectors · Physics 2020-03-31 Stephen Giblin , Jordan Tompkins

We describe a calibration setup for the transresistance of low-current amplifiers, based on the capacitance-charging method. The calibration can be performed in the current range of typical interest for electron counting experiments. The…

Instrumentation and Detectors · Physics 2016-10-18 Ilaria Finardi , Luca Callegaro

Accurate characterization of ferroelectric properties in polymer piezoelectrics is critical for optimizing the performance of flexible and wearable ultrasound transducers, such as screen-printed PVDF devices. Standard charge measurement…

Systems and Control · Electrical Eng. & Systems 2024-10-23 Marc-Andre Wessner , Federico Villani , Sofia Papa , Kirill Keller , Laura Ferrari , Francesco Greco , Luca Benini , Christoph Leitner

We broach a seldom-discussed topic in precision metrology; how subtle errors in calibration processes are discovered and remedied. We examine a case study at the National Physical Laboratory (NPL), UK, involving the calibration of DC…

Instrumentation and Detectors · Physics 2025-12-03 Stephen Giblin

We compared the performance of a commercial ammeter and a home-made integrating electrometer in reading ionisation chamber currents less than 100 pA. The integrating electrometer charges a capacitor with the unknown current and measures the…

Instrumentation and Detectors · Physics 2019-03-08 Stephen P. Giblin , Giuseppe Lorusso

Modern commercial direct-current current transformers (DCCT) can measure currents up to the kA range with accuracies better than 1E-5. We discuss here a DCCT calibration method and its implementation with commercial instruments typically…

Instrumentation and Detectors · Physics 2016-11-17 Luca Callegaro , Cristina Cassiago , Enrico Gasparotto

A well-characterised sample of silicon tunable-barrier electron pump has been operated at a frequency of 2 GHz using a custom drive waveform, generating a pump current of 320 pA. Precision measurements of the current were made as a function…

Mesoscale and Nanoscale Physics · Physics 2023-08-02 Stephen Giblin , Gento Yamahata , Akira Fujiwara , Masaya Kataoka

A programmable quantum current generator based on the application of Ohm's law to quantum voltage and resistance standards has demonstrated a realization of the ampere from the elementary charge with a $10^{-8}$ relative uncertainty [J.…

Instrumentation and Detectors · Physics 2021-08-11 Sophie Djordjevic , Ralf Behr , Dietmar Drung , Martin Götz , Wilfrid Poirier

Photoacoustic (PA) imaging systems are spreading in the biomedical community, and the de-velopment of new PA contrast agents is an active area of research. However, PA contrast agents are usually characterized with spectrophotometry or…

Instrumentation and Detectors · Physics 2022-09-07 Théotim Lucas , Mitradeep Sarkar , Yoann Atlas , Clément Linger , Gilles Renault , Florence Gazeau , Jérôme Gateau

A 128-channel picoammeter system is constructed based on instrumentation amplifiers. Taking the advantages of high electric potential and narrow bandwidth in DC energetic charged beam measurements, current resolution better than 5 fA can be…

Instrumentation and Detectors · Physics 2017-06-13 Deyang Yu , Junliang Liu , Yingli Xue , Mingwu Zhang , Xiaohong Cai , Jianjun Hu , Jinmei Dong , Xin Li

This paper presents non-destructive dark current measurements of superconducting TESLA cavities for superconducting LINACs. The measurements were carried out in a highly disturbed accelerator environment using a low temperature…

Instrumentation and Detectors · Physics 2015-05-19 R. Geithner , R. Neubert , W. Vodel , P. Seidel , K. Knaack , S. Vilcins , K. Wittenburg , O. Kugeler , J. Knobloch

The most common method to measure direct current high voltage (HV) down to the ppm-level is to use resistive high-voltage dividers. Such devices scale the HV into a range where it can be compared with precision digital voltmeters to…

Instrumentation and Detectors · Physics 2019-07-24 O. Rest , D. Winzen , S. Bauer , R. Berendes , J. Meisner , T. Thümmler , S. Wüstling , C. Weinheimer
‹ Prev 1 2 3 10 Next ›