Related papers: Characterization of the VEGA ASIC coupled to large…
A large-area Silicon Drift Detectors (SDDs) system has been developed by the SIDDHARTA2 collaboration for high precision light kaonic atoms X-ray spectroscopy at the DA{\Phi}NE collider of Istituto Nazionale di Fisica Nucleare - Laboratori…
We characterize a new x-ray Mixed-Mode Pixel Array Detector (MM-PAD-2.1) Application Specific Integrated Circuit (ASIC). Using an integrating pixel front-end with dynamic charge removal architecture, the MM-PAD-2.1 ASIC extends the maximum…
Scientific detectors are a key technological enabler for many disciplines. Application-specific integrated circuits (ASICs) are used for many of these scientific detectors. Until recently, pixel detector ASICs have been used mainly for…
Future strategic X-ray missions, such as the Advanced X-ray Imaging Satellite (AXIS) and those targeted by the Great Observatories Maturation Program (GOMaP), require fast, low-noise X-ray imaging spectrometers. To achieve the speed and…
Gotthard-II is a silicon microstrip detector developed for the European X-ray Free-Electron Laser (XFEL.EU). Its potential scientific applications include X-ray absorption/emission spectroscopy, hard X-ray high resolution single-shot…
This contribution presents a pragmatic approach to read-out electronics for drift chambers used in particle physics experiments, specifically for the R3B experiment at GSI. The design uses discrete miniature SMD components and LVDS inputs…
A front-end readout electronics system has been developed for silicon strip detectors. The system uses an application specific integrated circuit (ASIC) ATHED to realize multi-channel E&T measurement. The slow control of ASIC chips is…
The HERMES-TP/SP mission, based on a nanosatellite constellation, has very stringent constraints of sensitivity and compactness, and requires an innovative wide energy range instrument. The instrument technology is based on the "siswich"…
The SIDDHARTA-2 experiment at the DA$\Phi$NE collider of INFN-LNF performs high precision light kaonic atoms X-ray spectroscopy to investigate the kaon-nucleon(s) strong interaction in the low-energy (O(10 keV)) regime. A large area Silicon…
Joint progresses in Cd(Zn)Te detectors, microelectronics and interconnection technologies open the way for a new generation of instruments for physics and astrophysics applications in the energy range from 1 to 1000 keV. Even working…
We present our latest ASIC, which is used for the readout of Cadmium Telluride double-sided strip detectors (CdTe DSDs) and high spectroscopic imaging. It is implemented in a 0.35 um CMOS technology (X-Fab XH035), consists of 64 readout…
A readout electronics used in space cosmic-ray charges measurement for multi-channel silicon detector and its performance test results are introduced in this paper. A 64-channel charge sensitive ASIC (VA140) from IDEAS company is adopt in…
The basic principle of operation of silicon sensors with resistive read-out is built-in charge sharing. Resistive Silicon Detectors (RSD, also known as AC-LGAD), exploiting the signals seen on the electrodes surrounding the impact point,…
The silicon-strip tracker of the China Seismo-Electromagnetic Satellite (CSES) consists of two double-sided silicon strip detectors (DSSDs) which provide incident particle tracking information. The low-noise analog ASIC VA140 was used in…
The Advanced X-ray Imaging Satellite (AXIS) is a NASA probe class mission concept designed to deliver arcsecond resolution with an effective area ten times that of Chandra (at launch). The AXIS focal plane features an MIT Lincoln Laboratory…
We are developing position sensitive silicon detectors (PSDs) which have an electrode at each of four corners so that incident position of a charged particle can be obtained with signal from the electrodes. It is expected that the position…
We report on the design, production, and testing of advanced double-sided silicon strip detectors under development at the Max-Planck-Institute as part of the Medium Energy Gamma-ray Astronomy (MEGA) project. The detectors are designed to…
In order to achieve the driver function for several types of scientific CCD detector from E2V Co Ltd, and decreasing the size of electronics of CCD detector system, an Application-specified Integrated Circuit (ASIC) was designed. It…
The continued advancements of Silicon Photomultipliers (SiPMs) have made them viable photosensors for low recoil energy Pulse Shape Discrimination (PSD) between fast neutron and gamma interactions when coupled to an appropriate…
We evaluate the performances of a 100 um-thick silicon strip detector (SSD) with a 300 MeV proton beam and a 90Sr beta-ray source. Signals from the SSD have been read out using a VLSI chip. Common-mode noise, signal separation efficiency…