English
Related papers

Related papers: Generation of reference dc currents at 1 nA level …

200 papers

Modern commercial direct-current current transformers (DCCT) can measure currents up to the kA range with accuracies better than 1E-5. We discuss here a DCCT calibration method and its implementation with commercial instruments typically…

Instrumentation and Detectors · Physics 2016-11-17 Luca Callegaro , Cristina Cassiago , Enrico Gasparotto

At National Institute of Metrological Research (INRIM), an automated setup to calibrate DC Voltage generators, mainly top-level calibrators from 1 mV to 1 kV has been developed. The heart of the setup is an INRIM-built automated fixed…

Instrumentation and Detectors · Physics 2017-08-31 Flavio Galliana , Pier Paolo Capra , Roberto Cerri , Marco Lanzillotti

A standard method for picoammeter calibrations is the capacitor charging technique, which allows generating traceable currents in the sub-nA range. However, its accuracy is limited by the ac-dc differences of the capacitances involved. The…

Instrumentation and Detectors · Physics 2014-08-07 Hansjörg Scherer , Gerd-Dietmar Willenberg , Dietmar Drung , Martin Götz , Eckart Pesel

The inductive charging of electric vehicles requires specific measurement and calibration systems. In fact, the measurement of power on board involves DC signals, which are superimposed to a significant AC ripple up to or over 150 kHz,…

Instrumentation and Detectors · Physics 2019-05-21 M. Zucca , U. Pogliano , M. Modarres , D. Giordano , G. Crotti , D. Serazio

We present the comparison of results from the generation and the measurement of direct currents in the pA range, performed with traceable state-of-the-art methods at highest accuracy. The currents were generated with the capacitor charging…

Other Condensed Matter · Physics 2016-11-17 Hansjörg Scherer , Gerd-Dietmar Willenberg , Dietmar Drung , Martin Götz , Eckart Pesel

We describe a calibration setup for the transresistance of low-current amplifiers, based on the capacitance-charging method. The calibration can be performed in the current range of typical interest for electron counting experiments. The…

Instrumentation and Detectors · Physics 2016-10-18 Ilaria Finardi , Luca Callegaro

We report on new calibration methods for picoammeters and low-current sources. The "Ultrastable Low-noise Current Amplifier" (ULCA) was used for the exemplary calibration of commercial state-of-the-art ammeter and current source instruments…

Instrumentation and Detectors · Physics 2016-03-24 Hansjörg Scherer , Dietmar Drung , Christian Krause

In this paper, we present a programmable Ultra Low DC Current Source (ULCS) developed at T\"UB\.ITAK UME. The output current range is from 1 fA up to 100 pA with 100 aA resolution and is directly traceable to DC voltage, capacitance and…

Instrumentation and Detectors · Physics 2019-07-23 Omer Erkan , Yakup Gulmez , Cem Hayirli , Gulay Gulmez , Enis Turhan

We performed calibrations of four different commercial picoammeters using the Ultrastable Low-noise Current Amplifier (ULCA) as a calibrator current source operated in the range between 1 femtoampere and 1 microampere. The results allow the…

Instrumentation and Detectors · Physics 2018-11-26 Hansjörg Scherer , Dietmar Drung , Christian Krause , Martin Götz , Ulrich Becker

Nanoscale single-electron pumps can be used to generate accurate currents, and can potentially serve to realize a new standard of electrical current based on elementary charge. Here, we use a silicon-based quantum dot with tunable tunnel…

Mesoscale and Nanoscale Physics · Physics 2014-06-26 A. Rossi , T. Tanttu , K. Y. Tan , I. Iisakka , R. Zhao , K. W. Chan , G. C. Tettamanzi , S. Rogge , A. S. Dzurak , M. Möttönen

This paper describes a novel method for calibrating dc-precise magnetometers in the low field range (100 uT), which gives acceptable results even in laboratory conditions with significant magnetic interference. By introducing a closely…

Instrumentation and Detectors · Physics 2019-09-06 Michal Janosek , Michal Dressler , Vojtech Petrucha , Andrey Chirtsov

Mass characterisation of emerging memory devices is an essential step in modelling their behaviour for integration within a standard design flow for existing integrated circuit designers. This work develops a novel characterisation platform…

We measure the rectified dc currents resulting when a 3-terminal semiconductor device with gate-dependent conductance is driven with an ac gate voltage. The rectified currents exhibit surprisingly complex behaviour as the dc source-drain…

Mesoscale and Nanoscale Physics · Physics 2018-09-28 S. P. Giblin , M. Kataoka , J. D. Fletcher , P. See , T. J. B. M. Janssen , J. P. Griffiths , G. A. C. Jones , I. Farrer , D. A. Ritchie

This paper presents a new procedure for phase detector measurements that allows the use of generators that share a 10 MHz reference oscillator but do not synchronize in phase, in other words, quasi-synchronized RF generators. The objectives…

Systems and Control · Electrical Eng. & Systems 2024-02-08 V. A. Pulido , F. Cabrera-Almeida , P. Quintana-Morales , E. Mendieta-Otero

The most common method to measure direct current high voltage (HV) down to the ppm-level is to use resistive high-voltage dividers. Such devices scale the HV into a range where it can be compared with precision digital voltmeters to…

Instrumentation and Detectors · Physics 2019-07-24 O. Rest , D. Winzen , S. Bauer , R. Berendes , J. Meisner , T. Thümmler , S. Wüstling , C. Weinheimer

This paper presents the design and testing of a time-stretching-based time-to-digital converter (TDC) implemented with discrete components. The TDC utilizes capacitor charging and discharging to achieve a time resolution of under 100 ps…

Instrumentation and Detectors · Physics 2025-06-23 Yanbo Chu , Zhicai Zhang

An AC susceptometer operating in the range of 10 Hz to 100 kHz and at room temperature is designed, built, calibrated and used to characterize the magnetic behaviour of coated magnetic nanoparticles. Other weakly magnetic materials (in…

Instrumentation and Detectors · Physics 2013-12-18 M. Alderighi , G. Bevilacqua , V. Biancalana , Y. Dancheva , A. Khanbekyan , L. Moi

We detail the calibration of the D-dot probes used on the Los Alamos National Laboratory DARHT Axis 1 LIA compensation cans (CCs). We hope this will serve not only as a record of this calibration, but also as a guide on how to perform…

Accelerator Physics · Physics 2017-10-25 J. Martin Taccetti , Darin Westley , Jeffrey B. Johnson , Paul Flores

A programmable quantum current generator based on the application of Ohm's law to quantum voltage and resistance standards has demonstrated a realization of the ampere from the elementary charge with a $10^{-8}$ relative uncertainty [J.…

Instrumentation and Detectors · Physics 2021-08-11 Sophie Djordjevic , Ralf Behr , Dietmar Drung , Martin Götz , Wilfrid Poirier

This paper proposes a dynamic capacitance matching (DCM)-based RC current response algorithm for calculating the current waveform of a signal line without performing SPICE simulation. Specifically, unlike previous method such as CCS model,…

Systems and Control · Electrical Eng. & Systems 2024-01-17 Zhoujie Wu , Cai Luo , Zhong Guan
‹ Prev 1 2 3 10 Next ›