Related papers: Characterization and modeling of a low background …
Charge collection properties of depleted CMOS pixel detector prototypes produced on p-type substrate of 2 k$\Omega$cm initial resistivity (by LFoundry 150 nm process) were studied using Edge-TCT method before and after neutron irradiation.…
A low background Micromegas detector has been operating on the CAST experiment at CERN for the search of solar axions during the first phase of the experiment (2002-2004). The detector operated efficiently and achieved a very low level of…
Cosmic ray (CR) interactions can be a challenging source of background for neutrino oscillation and cross-section measurements in surface detectors. We present methods for CR rejection in measurements of charged-current quasielastic-like…
High Purity Germanium Detectors have excellent energy resolution; the best among the technologies used in double beta decay. Since neutrino-less double beta decay hinges on the search for a rare peak upon a background continuum, this…
A preliminary design of the 125 GeV Higgs Factory (HF) Muon Collider (MC) has identified an enormous background loads on the HF detector. This is related to the twelve times higher muon decay probability at HF compared to that previously…
HERMES (High Energy Rapid Modular Ensemble of Satellites) is an innovative mission aiming to observe transient high-energy events such as gamma-ray bursts (GRBs) through a constellation of CubeSats hosting a broadband X and gamma-ray…
The potential of GENIUS as a dark matter detector is discussed. A study was performed to demonstrate the good behaviour of the proposed detector design of naked HPGe-crystals in liquid nitrogen. The expected background components were…
Methods.There are no experimental data about the background experienced by microcalorimeters in the L2 orbit, and thus the particle background levels were calculated by means of Monte Carlo simulations: we considered the original design…
In the present work, we describe the results obtained with a large ($\approx 133$ cm$^3$) TeO$_2$ bolometer, with a view to a search for neutrinoless double-beta decay ($0\nu\beta\beta$) of $^{130}$Te. We demonstrate an efficient $\alpha$…
HPgTPCs have benefits such as low energy threshold, magnetisability, and 4$\pi$ acceptance, making them ideal for neutrino experiments such as DUNE. We present the design of an FPGA-based solution optimised for ND-GAr, which is part of the…
PoGOLino is a scintillator-based neutron detector. Its main purpose is to provide data on the neutron flux in the upper stratosphere at high latitudes at thermal and nonthermal energies for the PoGOLite instrument. PoGOLite is a balloon…
The existing Nuclear Resonance Fluorescence (NRF) setup at the HI{\gamma}S facility at the Triangle Universities Nuclear Laboratory at Duke University has been extended in order to perform {\gamma}-{\gamma} coincidence experiments. The new…
Renewable energy resources have emerged as the best alternatives to fossil fuel energy which are rapidly declining with time. Here, eight valence-electron count Half-Heusler(HH) alloys have been studied using reliable first principles…
High purity germanium (HPGe) detectors are ubiquitous in nuclear physics experiments and are also used in numerous low radioactive background detectors. The effect of the position of $^{60}$Co and $^{137}$Cs point sources on the shape of…
The IsoDAR sterile-neutrino search requires a very high intensity neutrino source. For IsoDAR, this high intensity is produced using the high neutron flux from a 60 MeV, 10 mA proton beam striking a beryllium target that floods a sleeve of…
The SABRE (Sodium Iodide with Active Background Rejection) experiment will search for an annually modulating signal from dark matter particles in our Galaxy using an array of ultra-pure NaI(Tl) detectors surrounded by an active scintillator…
The Majorana Collaboration is using an array of high-purity Ge detectors to search for neutrinoless double-beta decay in 76Ge. Searches for neutrinoless double-beta decay are understood to be the only viable experimental method for testing…
Nuclear recoil measurements with high-purity Germanium detectors are very promising to directly detect dark matter candidates. The main background sources in such experiments are natural radioactivity and microphonic noise. Digital pulse…
The Iron Calorimeter (ICAL) detector at the India based Neutrino Observatory (INO) is planned to be set up in an underground cavern with a rock overburden of more than 1 km. This overburden reduces the cosmic muon flux by a factor of…
The CYGNO project has the goal to use a gaseous TPC with optical readout to detect dark matter and solar neutrinos with low energy threshold and directionality. The CYGNO demonstrator will consist of 1 m 3 volume filled with He:CF 4 gas…