Related papers: Current Sensing Noise Thermometry: A fast practica…
We have designed low noise temperature sensing and control units with the objective of using them for the fabrication of far infrared active cavity radiometers. The sensing unit, first characterized at 300K using industrial platinium…
We developed an absolute Johnson noise thermometer (JNT), an instrument to measure the thermodynamic temperature of a sensing resistor, with traceability to voltage, resistance and frequency quantities. The temperature is measured in energy…
Resistance thermometry provides a time-tested method for taking temperature measurements. However, fundamental limits to resistance-based approaches has produced considerable interest in developing photonic temperature sensors to leverage…
We develop Johnson noise thermometry applicable to mesoscopic devices with variable source impedance with high bandwidth for fast data acquisition. By implementing differential noise measurement and two-stage impedance matching, we…
We have developed a nuclear magnetic resonance spectrometer with a series tuned input circuit for measurements on samples at millikelvin temperatures based on an integrated two-stage superconducting quantum interference device current…
We describe a compact calorimeter that opens ultra-low temperature heat capacity studies of small metal crystals in moderate magnetic fields. The performance is demonstrated on the canonical heavy Fermion metal YbRh2Si2. Thermometry is…
A vacuum compatible cryogenic accelerometer is presented which will reach $<0.5$ p$g$ Hz$^{-1/2}$ sensitivity from 1 mHz to 10 Hz with a maximum sensitivity of 10 f$g$ Hz$^{-1/2}$ around 10 Hz. This figure can be translated to a…
We describe the construction and operation of a two-channel noise detection system for measuring power and cross spectral densities of current fluctuations near 2 MHz in electronic devices at low temperatures. The system employs cryogenic…
Squeezing the quadrature noise of a harmonic oscillator used as a sensor can enhance its sensitivity in certain measurment schemes. The canonical approach, based on parametric modulation of the oscillation frequency, is usually limited to a…
Thermal equilibrium states are exponentially hard to distinguish at very low temperatures, making equilibrium quantum thermometry in this regime a formidable task. We present a thermometric scheme that circumvents this limitation, by using…
Thermal voltage noise measurements are performed in order to determine the electron temperature in nanopatterned channels of a GaAs/AlGaAs heterostructure at bath temperatures of 4.2 and 1.4 K. Two narrow two-dimensional (2D) heating…
A differential, membrane-based nanocalorimeter for general specific heat studies of very small samples, ranging from 0.5 mg to sub-{\mu}g in mass, is described. The calorimeter operates over the temperature range from above room temperature…
We demonstrate radiofrequency thermometry on a micrometer-sized metallic island below 100 mK. Our device is based on a normal metal-insulator-superconductor tunnel junction coupled to a resonator with transmission readout. In the first…
Classical ways of cooling require some of these elements: phase transition, compressor, non-linearity, valve, and/or switch. A recent example is the 2018 patent of Linear Technology Corporation; they utilize the shot noise of a diode to…
We develop a high frequency, wide bandwidth radiometer operating at room temperature, which augments the traditional technique of Johnson noise thermometry for nanoscale thermal transport studies. Employing low noise amplifiers and an…
We report temperature measurements using a transmon qubit by detecting the population of its first three energy levels, after applying a sequence of $\pi$-pulses and performing projective dispersive readout. We measure the effective…
We report the measurement of the current noise of a tunnel junction driven out-of-equilibrium by a temperature and/or voltage difference, i.e. the charge noise of heat and/or electrical current. This is achieved by a careful control of…
The precision of typical thermometers consisting of $N$ particles is shot noise limited, improving as $\sim1/\sqrt{N}$. For high precision thermometry and thermometric standards this presents an important theoretical noise floor. Here it is…
Dedicated read-out electronics was developed for low impedance resistive thermometers. Using this high performance temperature controller, the temperature dependence of the excess noise of a YBa2Cu307-d (YBCO) sample in the superconducting…
The thermometer and thermal control system, for the Absolute Radiometer for Cosmology, Astrophysics, and Diffuse Emission (ARCADE) experiment, is described, including the design, testing, and results from the first flight of ARCADE. The…