English
Related papers

Related papers: Error analysis and lattice improvement for the C-A…

200 papers

In a partnership with SLAC National Accelerator Laboratory (SLAC) and Jefferson Lab, Fermilab will assemble and test 17 of the 35 total 1.3 GHz cryomodules for the Linac Coherent Light Source II (LCLS-II) Project. These devices will be…

Accelerator Physics · Physics 2017-04-27 M. W. McGee , S. K. Chandrasekaran , A. C. Crawford , E. Harms , J. Leibfritz , G. Wu

An introduction and the status of R&D activities for a high-resolution, "cold" beam position monitor (BPM) and the related read-out electronics are discussed. Two different BPM detector concepts, to be attached to the SC quadrupole and…

Accelerator Physics · Physics 2009-02-19 M. Wendt , T. Lefevre , C. Simon , S. Vilalte

An S-band linear accelerator is the source of particles and the front end of the Advanced Photon Source injector. In addition, it supports a low-energy undulator test line (LEUTL) and drives a free-electron laser (FEL). A…

Accelerator Physics · Physics 2019-08-17 A. E. Grelick , N. Arnold , S. Berg , D. Dohan , G. Goeppner , Y. W. Kang , A. Nassiri , S. Pasky , G. Pile , T. Smith , S. J. Stein

Reducing the operating temperature of normal conducting particle accelerators substantially increases their efficiency. Low-temperature operation increases the yield strength of the accelerator material and reduces surface resistance, hence…

Accelerator Physics · Physics 2021-09-22 Mamdouh Nasr , Emilio Nanni , Martin Breidenbach , Stephen Weathersby , Marco Oriunno , Sami Tantawi

To maximize the physics potential of future neutrino oscillation experiments, it is proposed to build a 15-MW `proton driver' consisitng solely of a 3-GeV proton injector linac (PI) and a 17-GeV superconducting ILC-type linac (SCL). The…

Accelerator Physics · Physics 2019-03-25 Radoje Belusevic

Background and purpose: To propose a novel machine learning-based method for reliable and accurate modeling of linac beam data applicable to the processes of linac commissioning and QA. Materials and methods: We hypothesize that the beam…

Medical Physics · Physics 2020-10-07 Wei Zhao , Ishan Patil , Bin Han , Yong Yang , Lei Xing , Emil Schüler

The non-homogeneity in the critical temperature $T_{c}$ of an Microwave Kinetic Inductance Detector (MKID) could be caused by non-uniformity in the deposition process of the thin superconducting film. This produces low percent yield and…

Instrumentation and Detectors · Physics 2019-11-18 Israel Hernandez , Martin Makler , Juan Estrada , Clecio R. Bom , Donna Kubik , Julian Amette , Jorge Montes , Andrew Leptop

A concept for a two-stage injection-locked CW magnetron intended to drive Superconducting Cavities (SC) for intensity-frontier accelerators has been proposed. The concept considers two magnetrons in which the output power differs by 15-20…

We present the design and simulation of a 30 $\mathrm{\mu m}$ thick 4H-SiC Low Gain Avalanche Diode (LGAD) optimized for high-voltage operation. A 2.4 $\mathrm{\mu m}$ thick epitaxially grown gain layer enables controlled internal…

By analyzing large quantities of discharges in the unfavorable ion $ \vec B\times \nabla B $ drift direction, the I-mode operation has been confirmed in EAST tokamak. During the L-mode to I-mode transition, the energy confinement has a…

For the characterization of the 10 mA ion beam delivered by the new High Current Linac at GSI, sophisticated, mainly non-intersepting diagnostic devices were developed. Besides the general set-up of a versatile test bench, we discuss in…

Accelerator Physics · Physics 2007-05-23 P. Forck , F. Heymach , T. Hoffmann , A. Peters , P. Strehl

A Sagnac atom interferometer can be constructed using a Bose-Einstein condensate trapped in a cylindrically symmetric harmonic potential. Using the Bragg interaction with a set of laser beams, the atoms can be launched into circular orbits,…

Quantum Physics · Physics 2021-03-26 Zhe Luo , E R Moan , C A Sackett

Although accelerator technology has matured sufficiently, state-of-the-art X-ray linacs for radiotherapy and cargo-scanning capture merely 30-50% of the electrons from a thermionic cathode, requiring a higher cathode current and leaving…

Three alternative designs of the European Spallation Source (ESS) high energy linac are described. The most promising ones are either a normalconducting (nc) coupled cavity linac (CCL) up tofinal energy or a change at 407 MeV to only one…

Accelerator Physics · Physics 2007-05-23 M. Pabst , K. Bongardt , A. Letchford

We present an integrated three-knob tuner that internalizes impedance matching inside the launch adapter of a waveguide-fed, high-$Q$ cavity. The tuner combines a waveguide sliding short, a doorknob transition, and a micrometer-driven…

Plasma Physics · Physics 2026-02-04 Saptarshi Biswas , Sven G. Bilén

IJCLab has been leading the development and deployment of low-$\beta$ Superconducting Radio Frequency (SRF) cavities for proton and heavy ion accelerators. We are launching an electron accelerator project for sustainable Energy Recovery…

CSNS/RCS accelerates a high-intensity proton beam from 80 MeV to 1.6 GeV. Since the beam current and beam power is high, the beam loading is a severe problem for the stability of the circulating beam in the RCS. To study the beam loading…

Accelerator Physics · Physics 2015-06-22 Yao-Shuo Yuan , Kai-Wei Li , Na Wang , Yoshiro Irie , Sheng Wang

A Hybrid single cavity (HSC) linac, which is formed by combining a radio frequency quadrupole (RFQ) structure and a drift tube (DT) structure into one interdigital-H (IH) cavity, is fabricated and assembled as a proof of principle (PoP)…

Accelerator Physics · Physics 2016-08-03 Liang Lu

Integrated sensing and communication (ISAC) is a key technology for enabling a wide range of applications in future wireless systems. However, the sensing performance is often degraded by model mismatches caused by geometric errors (e.g.,…

Signal Processing · Electrical Eng. & Systems 2026-02-03 Hui Chen , Mengting Li , Alireza Pourafzal , Huiping Huang , Yu Ge , Sigurd Sandor Petersen , Ming Shen , George C. Alexandropoulos , Henk Wymeersch

The closed-off structure of the Fermilab Drift Tube Linac precludes a robust array of instrumentation from directly monitoring the H- beam that is accelerated from 750 keV to 116 MeV. To improve beam tuning and operational assessment of…

Accelerator Physics · Physics 2025-11-25 E. V. Chen , A. L. Saewert , R. V. Sharankova