Related papers: Radioactive Decays in Geant4
Novel radiotherapy techniques like synchrotron X-ray microbeam radiation therapy (MRT), require fast dose distribution predictions that are accurate at the sub-mm level, especially close to tissue/bone/air interfaces. Monte Carlo physics…
KM2A is one of the main sub-arrays of LHAASO, working on gamma ray astronomy and cosmic ray physics at energies above 10 TeV. Detector simulation is the important foundation for estimating detector performance and data analysis. It is a big…
We present g4chargeit, a kinetic Monte Carlo framework built on Geant4 for self-consistent simulation of time-dependent electrostatic charging in dielectric materials. The model explicitly incorporates stochastic particle transport and…
Purpose: To develop a Monte Carlo (MC) therapeutic dose calculation toolkit of a recently released ring gantry linac in Geant4 (Version 10.7) for secondary dose validation of radiotherapy plan. Methods: For the Halcyon (Varian Medical…
A model for the simulation of orientational effects in straight and bent periodic atomic structures is presented. The continuum potential approximation has been adopted.The model allows the manipulation of particle trajectories by means of…
For high precision measurements of K decays, the presence of radiated photons cannot be neglected. The Monte Carlo simulations must include the radiative corrections in order to compute the correct event counting and efficiency…
Galactic cosmic rays undergo complex nuclear interactions with nuclei within planetary bodies that have little to no atmosphere. Radiation transport simulations are a key tool used in understanding the neutron and gamma-ray albedo coming…
A proton pencil beam is associated with a surrounding low-dose envelope, originating from nuclear interactions. It is important for treatment planning systems to accurately model this envelope when performing dose calculations for pencil…
A Geant4 based simulation platform of the Holland Proton Therapy Centre (HollandPTC, Netherlands) R&D beamline (G4HPTC-R&D) was developed to enable the planning, optimisation and advanced dosimetry for radiobiological studies. It…
CMS experiment is using Geant4 for Monte-Carlo simulation of the detector setup. Validation of physics processes describing hadronic showers is a major concern in view of getting a proper description of jets and missing energy for signal…
Ongoing investigations for the improvement of Geant4 accuracy and computational performance resulting by refactoring and reengineering parts of the code are discussed. Issues in refactoring that are specific to the domain of physics…
Purpose: To validate the accuracy of 4D Monte Carlo (4DMC) simulations to calculate dose deliveries to a deforming anatomy in the presence of realistic respiratory motion traces. A previously developed deformable lung phantom comprising an…
In this work, we propose a novel technique for in-vivo proton therapy range verification. This technique makes use of a small hadron tumour marker, $^{92}$Mo, implanted at a short known distance from the clinical treatment volume. Signals…
Monte Carlo simulations are powerful tools for understanding the effects of radiation interactions within detector devices allowing not only to evaluate typical estimates for experimental measurements and to serve as means for designing…
A comprehensive analysis of the effects of Geant4 algorithms for condensed transport in detectors is in progress. The first phase of the project focuses on electron multiple scattering, and studies two related observables: the longitudinal…
Typically used as a tool for Monte Carlo simulation of high energy physics experiments, GEANT4 is increasingly being employed for the simulation of complex radiotherapy treatments. Often the specification of components within a clinical…
A R&D project has been recently launched to investigate Geant4 architectural design in view of addressing new experimental issues in HEP and other related physics disciplines. In the context of this project the use of generic programming…
Geant4 is a toolkit for the simulation of the passage of particles through matter. It provides a comprehensive set of tools for geometry, tracking, detector response, run, event and track management, visualization and user interfaces.…
We present density response estimators for Monte Carlo simulations that are based on a reweighting procedure, where the samples of an unperturbed system are used to estimate the properties of a system perturbed by an external harmonic…
A linear Breit-Wheeler module for the code Geant4 has been developed. This allows signal-to-noise ratio calculations of linear Breit-Wheeler detection experiments to be performed within a single framework. The interaction between two photon…