Related papers: A normal-pressure MWPC for beam diagnostics at RIB…
A simple routine is proposed for monitoring the efficiency value of a low pressure pentane filled multi-wire proportional chamber (MWPC) in long term experiments. The proposed algorithm utilizes a two parameter approximation for the…
We report on a newly developed scanning positron microbeam based on threefold moderation of positrons provided by the high intensity positron source NEPOMUC. For brightness enhancement a remoderation unit with a $100\,$nm thin Ni(100) foil…
A 1M- and a 4M-pixel monolithic CMOS active pixel sensor with 9.5x9.5 micron^2 pixels have been developed for direct imaging in transmission electron microscopy as part of the TEAM project. We present the design and a full characterisation…
A low pressure time projection chamber for the detection of WIMPs is discussed. Discrimination against Compton electron background in such a device should be very good, and directional information about the recoil atoms would be obtainable.…
A MICROMEGAS detection amplifier has been incorporated into the design of the TAMU MDM focal plane detector with the purpose of improving the energy resolution and thus, the particle identification. Beam tests showed a factor of 2…
Micro-pattern gas detectors, such as the Gas Electron Multiplier (GEM) and the Micromegas need narrow high density anode readout elements to achieve good spatial resolution. A high-density anode readout would require an unmanageable number…
The energy range above 60 keV is important for the study of many open problems in high energy astrophysics such as the role of Inverse Compton with respect to synchrotron or thermal processes in GRBs, non thermal mechanisms in SNR, the…
The use of differential phase contrast (DPC) in scanning transmission electron microscopy (STEM) has shown much promise for directly investigating the functional properties of a material system, leveraging the natural coupling between the…
Large Resistive Plate Chamber systems have their roots in High Energy Physics experiments at the European Organization for Nuclear Research: ATLAS, CMS and ALICE, where hundreds of square meters of both trigger and timing RPCs have been…
The STAR experiment at RHIC is planning to upgrade the Time Projection Chamber which lies at the heart of the detector. We have designed an instrument to measure the tension of the wires in the multi-wire proportional chambers (MWPCs) which…
The quadrant silicon detector, a kind of passivated implanted planar silicon detector with quadrant structure on the junction side, gained its wide application in charged particle detection. In this paper, the manufacturing procedure,…
The g2p/GEp experiments used a solid NH3 polarized target, where the polarization of the target is sensitive to temperature and radiation. The beam current was limited to 5-100 nA during the experiment to avoid too much depolarization of…
We report initial results from the design and evaluation of two pixellated PIN Cadmium Zinc Telluride detectors and an ASIC-based readout system. The prototype imaging PIN detectors consist of 4X4 1.5 mm square indium anode contacts with…
Robust localization of lymph nodes (LNs) in multiparametric MRI (mpMRI) is critical for the assessment of lymphadenopathy. Radiologists routinely measure the size of LN to distinguish benign from malignant nodes, which would require…
An advanced technique for a two-dimensional real time visualization of cluster beams in vacuum as well as of the overlap volume of cluster beams with particle accelerator beams is presented. The detection system consists of an array of…
A large area Resistive Plate Chamber (RPC) with a total active surface of 160x10 cm2 was built and tested. The surface was segmented in two 5 cm wide strips readout on both ends with custom, very high frequency, front end electronics. A…
The Multipurpose Detector (MPD) \cite{cite1.MPD_CDR} is designed to study of hot and dense baryonic matter in collisions of heavy ions over the atomic mass range 1--197 at the centre of mass energy up to $\sqrt{S_{NN}}$ = 11 GeV (for…
3D silicon detectors are characterized by cylindrical electrodes perpendicular to the surface and penetrating into the bulk material in contrast to standard Si detectors with planar electrodes on its top and bottom. This geometry renders…
The NEXT-White detector, a high-pressure gaseous xenon time projection chamber, demonstrated the excellence of this technology for future neutrinoless double beta decay searches using photomultiplier tubes (PMTs) to measure energy and…
A conceptual design work and a basic experimental study of a new beam profile monitor have been performed. The monitor will be used to measure emittance of an electron beam in the ATF damping ring at KEK, in which the transverse beam size…