The chamber for direct detection of WIMP with mass <0.5 Gev/c2 was developed. The chamber is filled with gas mixture Ne+10%H2 (0-1bar)+0,15ppm Ge(CH3)4. For events detection used GEM+pin-anodes , which provides the energy threshold about…
Micro-Pattern Gaseous Detectors (MPGDs) with resistive anode planes provide intrinsic discharge robustness while maintaining good spatial and time resolutions. Typically read out with 1D strips or pad structures, here the characterisation…
A cylindrical GEM tracker is under construction in order to replace and improve the inner tracking system of the BESIII experiment. Tests with planar chamber prototypes were carried out on the H4 beam line of SPS (CERN) with muons of 150…
Precise sensing and control of spatial mode content is essential for the performance of precision optical systems, particularly interferometric gravitational-wave detectors, where misalignment and mode mismatch can lead to significant…
The limitation of the detection rate of standard bakelite resistive plate chambers (RPC) used as muon detectors in the LHC experiments has prevented the use of such detectors in the high rate regions in both CMS and ATLAS detectors. One…
A strip-readout parallel-plate avalanche counter (SR-PPAC) has been developed aiming at the high detection efficiency and good position resolution in high-intensity heavy-ion measurements. The performance was evaluated using 115 MeV/u…
Bubble Chambers provided the dominant particle detection technology in accelerator experiments for several decades, eventually falling into disuse with the advent of other techniques. We report here on the first period of operation of an…
Principles of operation, construction and first test results of a Dielectric Resistive Plate Chamber (DRPC) are described. The detector has shown stability of operation in the avalanche mode of gas amplfication within a wide range of…
There is growing interest in high-energy astrophysics community for the development of sensitive instruments in the hard X-ray energy extending to few hundred keV. This requires position sensitive detector modules with high efficiency in…
In order to test the performance of detector/prototype in environment of laboratory, we design and build a larger area ($90\times52$ $cm^2$) test platform of cosmic ray based on well-designed Multi-gap Resistive Plate Chamber (MRPC) with an…
This paper presents the mathematical modeling-based design and simulation of normal mode MEMS capacitive pressure sensor for blood pressure sensing application. The normal blood pressure of human being is 120/80 mmHg. But this range varies…
We have been developing a high-pressure xenon gas time projection chamber (TPC) to search for neutrinoless double beta ($0\nu\beta\beta$) decay of $^{136}$Xe. The unique feature of this TPC is in the detection part of ionization electrons,…
A large (240 cm $\times$ 120 cm $\times$ 0.2 cm) oil-free High Pressure Laminate (HPL), commonly referred as "bakelite", Resistive Plate Chamber (RPC) has been developed at VECC-Kolkata using locally available P-302 OLTC grade HPL. The…
A prototype of a position sensitive photo-detector with 5.6 x 5.6 cm2 detection area readout with 64 Hamamatsu MPPCs (S10931-100P) with 3 x 3 mm2 active area each has been built and tested. The photo-sensors are arranged in a 8 x 8 array…
The characteristics and performance of a Dual Position Sensitive Multi-Wire Proportional Counter (DPS-MWPC) used to measure the scattering angle, interaction position on the target and the velocity of reaction products, detected in the…
The construction of a micro-pattern gas detector of dimensions 40x10 cm**2 is described. Two gas electron multiplier foils (GEM) provide the internal amplification stages. A two-layer readout structure was used, manufactured in the same…
We present the performance of a new proportional gas detector. Its geometry consists of a cathode plane with 70x70 micron apertures, crossed by 25 micron anode strips to which it is attached by 50 micron kapton spacers. In the region where…
The TPC for the International Linear Collider (ILC) will need to measure about 200 track points with a transverse resolution close to 100 microns. The resolution goal is beyond the capability of the conventional proportional wire/cathode…
Characteristics improvement of photon/plasmon detectors have been the subject of several investigations in the area of plasmonic integrated circuits. Among different suggestions, Silicon-based Metal-Semiconductor-Metal (MSM) waveguides are…
We present an innovative charge detector with high resolution and wide dynamic range designed to fulfill the requirements of a monitoring system for a high energy ion beam. The detector prototype, constructed using Si photodiodes and a…