Beam Charge Measurement for the g2p/GEp experiments

Instrumentation and Detectors 2016-06-28 v2

Abstract

The g2p/GEp experiments used a solid NH3 polarized target, where the polarization of the target is sensitive to temperature and radiation. The beam current was limited to 5-100 nA during the experiment to avoid too much depolarization of target (The typical Hall A running condition for beam current is 1 uA to 100 uA). The measured charge was further used to get the accurate physics cross sections. New BCM (Beam Current Monitor) receivers and a DAQ system were used to measure the beam current at such a low current range. A tungsten calorimeter was used to calibrate the BCMs. This technical note summarizes the calibration procedure and the performance of the BCMs.

Keywords

Cite

@article{arxiv.1606.02600,
  title  = {Beam Charge Measurement for the g2p/GEp experiments},
  author = {Pengjia Zhu},
  journal= {arXiv preprint arXiv:1606.02600},
  year   = {2016}
}

Comments

22 pages, JLab Tech Note, 2016