Next-generation megawatt-scale neutrino beams open the way to studying neutrino-nucleus scattering using gaseous targets for the first time. This represents an opportunity to improve the knowledge of neutrino cross sections in the energy…
The Resistive Plate Chambers (RPCs) are employed in the CMS experiment at the LHC as dedicated trigger system both in the barrel and in the endcap. This note presents results of the radiation background measurements performed with the 2011…
The fission Time Projection Chamber (fissionTPC) is a compact (15 cm diameter) two-chamber MICROMEGAS TPC designed to make precision cross section measurements of neutron-induced fission. The actinide targets are placed on the central…
The time resolution of Multigap Resistive Plate Counters (MRPCs) to $511$ keV gamma rays has been investigated using a $^{22}$Na source and four detectors. The MRPCs time resolution has been derived from the Time-of-Flight information,…
SHiP (Search for Hidden Particles) is a proposed experiment to be installed at CERN, with the aim of exploring the high intensity beam frontier to investigate the so-called Hidden sector. Since the SPS proton beam interacting with the SHiP…
A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget…
The Multigap Resistive Plate Chamber (MRPC) is a gaseous detector; the performance depends very much on the gas mixture as well as the design. MRPCs are used as a timing device in several collider experiments and cosmic ray experiments…
Resistive Plate Chamber (RPC) is a type of gaseous detector having excellent time and position resolutions. VECC is involved in the R\&D of indigenously developed bakelite RPCs. The largest size of bakelite RPC developed in India is 100 cm…
Resistive gaseous detectors can be broadly defined as those operated in conditions where virtually no field lines exist that connect any two metallic electrodes sitting at different potential. This condition can be operationally recognized…
Recently, the facilities of radioactive ion beam (RIB) combined with advanced detector systems provide us unique opportunity to probe the exotic properties of the nuclei with unusual neutron-to-proton ratio. In this article, a study of…
We developed a prototype time projection chamber using gas electron multipliers (GEM-TPC) for high energy heavy ion collision experiments. To investigate its performance, we conducted a beam test with 3 kinds of gases (Ar(90%)-CH4(10%),…
In June 2008 single-sided silicon strip sensors with 50 $\mu$m readout pitch were tested in a highly energetic pion beam at the SPS at CERN. The purpose of the test was to evaluate characteristic detector properties by varying the strip…
We report on the successful operation of a double phase Liquid Argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC) equipped with two dimensional projective anodes with dimensions 10$\times$10 cm$^2$, and with a maximum…
In the last years, high-resolution time tagging has emerged as the tool to tackle the problem of high-track density in the detectors of the next generation of experiments at particle colliders. Time resolutions below 50ps and event average…
The innermost station of the present ATLAS forward muon detector needs to be upgraded for the super-LHC. We present a proposal to replace it with a sandwiched detector composed of several layers of small-radius Monitored Drift Tube chambers…
The world's leading directional dark matter experiments currently all utilize low-pressure gas Time Projection Chamber (TPC) technologies. We discuss some of the challenges for this technology, for which balancing the goal of achieving the…
The ATLAS Muon Spectrometer is undergoing a major upgrade for the High-Luminosity LHC (HL-LHC), including the addition of three new thin-gap Resistive Plate Chamber (RPC) layers in the inner barrel region. These RPCs have 1 mm gas gaps…
The low cost and high resolution Multi-gap Resistive Plate Chamber (MRPC) opens up a new possibility to find an efficient alternative detector for the Time of Flight (TOF) based Positron Emission Tomography, where the sensitivity of the…
The intrinsic rate capability and the ageing properties of the Resistive Plate Chambers are closely related to the electrodes material and to the front-end electronics threshold. The development of a low noise pre-amplifier led us to…
A prototype of Multi-Wire Proportional Chambers (MWPC) has been fabricated for the study of its various characteristics. The detector contains gold-coated tungsten wires (20 $\mu m$ diameter) on the anode frame, with a pitch of 2.8 mm. The…