English
Related papers

Related papers: Neutron imaging detector based on the muPIC micro-…

200 papers

We show data from a new type of detector that can be used to determine neutron flux, energy distribution, and direction of neutron motion for both fast and thermal neutrons. Many neutron detectors are plagued by large backgrounds from…

The MuPix7 is a prototype high voltage monolithic active pixel sensor with 103 times 80 um2 pixels thinned to 64 um and incorporating the complete read-out circuitry including a 1.25 Gbit/s differential data link. Using data taken at the…

Beam monitoring and evaluation are very important to boron neutron capture therapy (BNCT), and a variety of detectors have been developed for these applications. However, most of the detectors used in BNCT only have a small detection area,…

Instrumentation and Detectors · Physics 2023-06-14 Zhujun Fang , Zhiyong Zhang , Bin Shi , Wei Jiang , Xianke Liu , Siqi He , Jun Chen , Ping Cao , Jianbei Liu , Yi Zhou , Ming Shao , Botian Qu , Shufeng Zhang , Qian Wang

A semiconductor tracker for muon scattering tomography is presented. The tracker contains silicon strip sensors with an $80\,\mu$m pitch, precision mechanics and integrated cooling. The electronic readout of the sensors is performed by a…

Instrumentation and Detectors · Physics 2018-10-30 F. Keizer , A. Gorbatch , M. A. Parker , C. Steer , S. A. Wotton

The study of the properties of the quantum states of bouncing neutrons requires position sensitive detection with micro-metric spatial resolution. The UCNBoX detector relies on Charge Coupled Devices (CCD) coated with a thin boron-10…

Instrumentation and Detectors · Physics 2022-07-27 B. Clément , L. Gesson , T. Jenke , V. V. Nesvizhevsky , G. Pignol , S. Roccia , J. -P. Scordillis

The search for neutrinoless double beta decay ($0\nu\beta\beta$) remains one of the most compelling experimental avenues for the discovery in the neutrino sector. Electroluminescent gas-phase time projection chambers are well suited to…

Instrumentation and Detectors · Physics 2023-08-04 NEXT Collaboration , N. K. Byrnes , I. Parmaksiz , C. Adams , J. Asaadi , J Baeza-Rubio , K. Bailey , E. Church , D. González-Díaz , A. Higley , B. J. P. Jones , K. Mistry , I. A. Moya , D. R. Nygren , P. Oyedele , L. Rogers , K. Stogsdill , H. Almazán , V. Álvarez , B. Aparicio , A. I. Aranburu , L. Arazi , I. J. Arnquist , S. Ayet , C. D. R. Azevedo , F. Ballester , M. del Barrio-Torregrosa , A. Bayo , J. M. Benlloch-Rodríguez , F. I. G. M. Borges , S. Bounasser , S. Cárcel , J. V. Carrión , S. Cebrián , L. Cid , C. A. N. Conde , T. Contreras , F. P. Cossío , E. Dey , G. Díaz , T. Dickel , M. Elorza , J. Escada , R. Esteve , A. Fahs , R. Felkai , L. M. P. Fernandes , P. Ferrario , A. L. Ferreira , F. W. Foss , E. D. C. Freitas , Z. Freixa , J. Generowicz , A. Goldschmidt , J. J. Gómez-Cadenas , R. González , J. Grocott , R. Guenette , J. Haefner , K. Hafidi , J. Hauptman , C. A. O. Henriques , J. A. Hernando Morata , P. Herrero-Gómez , V. Herrero , C. Hervés Carrete , J. Ho , P. Ho , Y. Ifergan , L. Labarga , L. Larizgoitia , P. Lebrun , F Lopez , D. Lopez Gutierrez , N. López-March , R. Madigan , R. D. P. Mano , A. P. Marques , J. Martín-Albo , G. Martínez-Lema , M. Martínez-Vara , Z. E. Meziani , R. L. Miller , F. Monrabal , C. M. B. Monteiro , F. J. Mora , J. Muñoz Vidal , K. E. Navarro , P. Novella , A. Nuñez , E. Oblak , M. Odriozola-Gimeno , J. Palacio , B. Palmeiro , A. Para , J Pelegrin , M. Pérez Maneiro , M. Querol , A. B. Redwine , J. Renner , I. Rivilla , J. Rodríguez , C. Rogero , B. Romeo , C. Romo-Luque , F. P. Santos , J. M. F. dos Santos , A. Simón , S. R. Soleti , M. Sorel , C. Stanford , J. M. R. Teixeira , J. F. Toledo , J. Torrent , A. Usón , J. F. C. A. Veloso , T. T. Vuong , J. Waiton , J. T. White

The construction of a micro-pattern gas detector of dimensions 40x10 cm**2 is described. Two gas electron multiplier foils (GEM) provide the internal amplification stages. A two-layer readout structure was used, manufactured in the same…

Muography (or muon radiography) is an imaging technique that relies on the use of cosmogenic muons as a free and safe radiation source. It can be applied in various fields such as archaeology, civil engineering, geology, nuclear reactor…

To achieve high-resolution muography of compact targets in scenarios with complex logistical constraints, we are developing a portable muon detector system utilizing glass Resistive Plate Chambers (RPCs). Although RPCs are well understood…

The response of a position-sensitive Li-glass scintillator detector being developed for thermal-neutron detection with 6 mm position resolution has been investigated using collimated beams of thermal neutrons. The detector was moved…

The Dark Matter Time Projection Chamber (DMTPC) experiment uses CF_4 gas at low pressure (0.1 atm) to search for the directional signature of Galactic WIMP dark matter. We describe the DMTPC apparatus and summarize recent results from a…

Muon radiography often referred to as muography, is an imaging technique that uses freely available cosmic-ray muons to study the interior structure of natural or man-made large-scale objects. The amount of multidisciplinary applications of…

We present the results of neutron detection in a laser plasma experiment with a CD$_2$ nanowire target. A hybrid semiconductor pixel detector Timepix3 covered with neutron converters was used for the detection of neutrons. D-D fusion…

The Multipurpose Detector (MPD) \cite{cite1.MPD_CDR} is designed to study of hot and dense baryonic matter in collisions of heavy ions over the atomic mass range 1--197 at the centre of mass energy up to $\sqrt{S_{NN}}$ = 11 GeV (for…

The rate of nuclear muon capture by the proton has been measured using a new experimental technique based on a time projection chamber operating in ultra-clean, deuterium-depleted hydrogen gas at 1 MPa pressure. The capture rate was…

The NUCLEUS experiment aims to measure coherent elastic neutrino nucleus scattering of reactor anti-neutrinos using cryogenic calorimeters. Operating at an overburden of 3 m.w.e., muon-induced backgrounds are expected to be one of the…

Advancements in high temperature superconducting technology have opened a path toward high-field, compact fusion devices. This new parameter space introduces both opportunities and challenges for diagnosis of the plasma. This paper presents…

In order to measure the energy of neutron fields, with energy ranging from 8 keV to 1 MeV, a new primary standard is being developed at the IRSN (Institute for Radioprotection and Nuclear Safety). This project, micro-TPC (Micro Time…

Two detection systems based on optical readout were developed: a. Integrative optical detector A 2nd generation of Time-Resolved Integrative Optical Neutron (TRION) detector was developed. It is based on an integrative optical technique,…

Instrumentation and Detectors · Physics 2017-05-01 Ilan Mor

The influence of fast neutrons on the occupancy and the single tube resolution of ATLAS muon drift detectors was investigated by exposing a chamber built out of 3 layers of 3 short standard drift tubes to neutron flux-densities of up to 16…

Instrumentation and Detectors · Physics 2016-11-18 T. Mueller , A. Mlynek , O. Biebel , R. Hertenberger , T. Nunnemann , D. Merkl , F. Rauscher , D. Schaile , R. Stroehmer