English
Related papers

Related papers: Neutron imaging detector based on the muPIC micro-…

200 papers

An optimized design of a neutron detector based on timing RPCs (Resistive Plate Chambers) with boron-10 neutron converters is presented. The detector is composed of a stack of ten double gap RPCs with aluminium cathode plates coated on both…

Instrumentation and Detectors · Physics 2023-05-03 L. M. S. Margato , G. Canezin , A. Morozov , A. Blanco , J. Saraiva , L. Lopes , P. Fonte

We report on the performance of a micro-TPC with a micro pixel chamber($\mu$-PIC) readout for a time-resolved neutron position-sensitive detector(PSD). Three-dimensional tracks and the Bragg curves of protons with energies of around 1 MeV…

Instrumentation and Detectors · Physics 2015-06-26 Kentaro Miuchi , Hidetoshi Kubo , Tsutomu Nagayoshi , Reiko Orito , Atsushi Takada , Atsushi Takeda , Toru Tanimori , Masaru Ueno

Presented here are results of simulations of neutron background performed for a time projection chamber acting as a particle dark matter detector in an underground laboratory. The investigated background includes neutrons from rock and…

We present the development of the miniTimeCube (mTC), a novel compact neutrino detector. The mTC is a multipurpose detector, aiming to detect not only neutrinos but also fast/thermal neutrons. Potential applications include the…

A new type of cold/ultracold neutron detector that can realize a spatial resolution of less than 100 nm was developed using nuclear emulsion. The detector consists of a fine-grained nuclear emulsion coating and a 50-nm thick $^{10}$B$_4$C…

Instrumentation and Detectors · Physics 2018-12-05 N. Naganawa , T. Ariga , S. Awano , M. Hino , K. Hirota , H. Kawahara , M. Kitaguchi , K. Mishima , H. M. Shimizu , S. Tada , S. Tasaki , A. Umemoto

In non-destructive evaluation with X-rays light elements embedded in dense, heavy (or high-Z) matrices show little contrast and their structural details can hardly be revealed. Neutron radiography, on the other hand, provides a solution for…

Instrumentation and Detectors · Physics 2015-02-03 A. S. Tremsin , V. Dangendorf , K. Tittelmeier , B. Schillinger , M. Schulz , M. Lerche , W. B. Feller

The micropattern gaseous detector Micromegas has been developed for several years in Saclay and presents good performance for neutron detection. A prototype for neutron imaging has been designed and new results obtained in thermal neutron…

An important issue for rare-event-search experiments, such as the search for dark matter or neutrinoless double beta decay, is to reduce radioactivity of the detector materials and the experimental environment. The selection of materials…

Instrumentation and Detectors · Physics 2020-01-29 H. Ito , T. Hashimoto , K. Miuchi , K. Kobayashi , Y. Takeuchi , K. D. Nakamura , T. Ikeda , H. Ishiura

Position-sensitive detection of ultracold neutrons (UCNs) is demonstrated using an imaging charge-coupled device (CCD) camera. A spatial resolution less than 15 $\mu$m has been achieved, which is equivalent to an UCN energy resolution below…

We developed a 12-liter volume neutron detector filled with the liquid scintillator EJ301 that measures neutrons in an underground laboratory where dark matter and neutrino experiments are located. The detector target is a cylindrical…

Instrumentation and Detectors · Physics 2015-06-15 C. Zhang , D. -M. Mei , P. Davis , B. Woltman , F. Gray

A new high-precision detector for studying neutrons from beta-delayed neutron emission and direct reaction studies is proposed. The Neutron dEtector with Xn Tracking (NEXT) array is designed to maintain high intrinsic neutron detection…

Two-dimensional solid state gaseous detector for thermal and cold neutrons is created. The detector has active area of 128 x 128 $mm^2$, $^{10}B$ neutron converter, and gas chamber with thin windows. The resistive charge-division readout is…

Instrumentation and Detectors · Physics 2017-04-05 S Potashev , Yu Burmistrov , A Drachev , S Karaevsky , E Konobeevski , S Zuyev

A micro time-projection-chamber (micro-TPC) with a detection volume of 23*28*31 cm^3 was developed, and its fundamental performance was examined. The micro-TPC consists of a micro pixel chamber with a detection area of 31*31 cm^2 as a…

We report on the design, production, and performance of compact 40-cm$^3$ Time Projection Chambers (TPCs) that detect fast neutrons by measuring the three-dimensional (3D) ionization distribution of nuclear recoils in $^4$He:CO$_2$ gas at…

The MuCap experiment at the Paul Scherrer Institute performed a high-precision measurement of the rate of the basic electroweak process of nuclear muon capture by the proton, $\mu^- + p \rightarrow n + \nu_\mu$. The experimental approach…

A tracking detector system has been constructed with an innovative approach to the classical multi-wire proportional chamber concept, using contemporary technologies. The detectors, covering an area of 0.58 square meters each, are optimized…

Instrumentation and Detectors · Physics 2016-08-30 Dezső Varga , Gábor Nyitrai , Gergő Hamar , László Oláh

In this work, we have developed and characterized a position-sensitive CLYC detector that acts as the neutron imaging layer and $\gamma$-ray Compton scatterer of the novel dual \g-ray and neutron imaging system GN-Vision, which aims at…

Multilayer position-sensitive 10B-RPC thermal neutron detectors offer an attractive combination of sub-millimeter spatial resolution and high (>50%) detection efficiency. Here we describe a new position reconstruction method based on a…

Instrumentation and Detectors · Physics 2021-09-01 A. Morozov , L. M. S. Margato , V. Solovov , A. Blanco , J. Saraiva , T. Wilpert , K. Zeitelhack , K. Roemer , C. Höglund , L. Robinson , R. Hall-Wilton

To address the problem of the shortage of neutron detectors used in radiation portal monitors (RPMs), caused by the 3He supply crisis, research on a cadmium-based capture-gated fast neutron detector is presented in this paper. The detector…

Instrumentation and Detectors · Physics 2016-08-03 Yi Liu , Yigang Yang , Yang Tai , Zhi Zhang