Related papers: The 10 Tesla muSR instrument: detector solutions
The apparatus of the ALICE experiment at CERN will be upgraded in 2017/18 during the second long shutdown of the LHC (LS2). A major motivation for this upgrade is to extend the physics reach for charmed and beauty particles down to low…
For reconstruction of the spatial structure of many-component objects, it is proposed to use multi-radiography with detection of X-ray by combined detector arrays using detectors of ``scintillator-photodiode'' type. A theoretical model has…
Transition-edge sensors (TESs) are capable of highly accurate single particle energy measurement. TESs have been used for a wide range of photon detection applications, particularly in astronomy, but very little consideration has been given…
Avalanche photodiode (APD) has been intensively investigated as a promising candidate to replace photomultiplier tubes (PMT) for weak light detection. However, in conventional APDs, a large portion of carrier energy drawn from the electric…
We report radiation hardness tests performed at the Frascati Neutron Generator on silicon Photo-Multipliers, semiconductor photon detectors built from a square matrix of avalanche photo-diodes on a silicon substrate. Several samples from…
An instrument has been developed for precision controlled exposures of electronic devices and material samples in particle beams. The instrument provides simultaneously a real time record of the profile of the beam and the fluence received.…
Superconducting transition-edge sensors (TESs) carried by X-ray telescopes are powerful tools for the study of neutron stars and black holes. Several methods, such as optimal filtering or principal component analysis, have already been…
For reconstruction of the spatial structure and thicknesses of complex objects and materials, it is proposed to use multi-radiography with detection of X-ray or gamma-radiation by combined detector arrays of scintillator-photodiode type.…
Transition-edge sensors (TES) are photon-number resolving calorimetric spectrometers with near unit efficiency. Their recovery time, which is on the order of microseconds, limits the number resolving ability and timing accuracy in high…
Photonic quantum technologies such as effective quantum communication require room temperature (RT) operating single- or few- photon sensors with high external quantum efficiency (EQE) at 1550 nm wavelength. The leading class of devices in…
We describe the design, construction and performance of the PIBETA detector built for the precise measurement of the branching ratio of pion beta decay, pi+ -> pi0 e+ nu, at the Paul Scherrer Institute. The central part of the detector is a…
We present a momentum measurement method based on multiple Coulomb scattering (MCS) in the FASER$\nu$ emulsion detector. The measurement of charged-particle momenta is essential for studying neutrino interactions in the TeV energy range at…
Detectors with an electroluminesence readout show an excellence performance in respect of energy resolution making them interesting for various applications as X-ray detection, double beta and dark matter experiments, Compton and gamma…
We present the design, construction, and performance of a facility for the characterization of Silicon Avalanche Photodiodes in the operating temperature range between -2 $^\circ$C and 25 $^\circ$C. The system can simultaneously measure up…
We report on the first integration of novel magnetic microcalorimeter detectors (MMCs), developed within SPARC (Stored Particles Atomic Physics Research Collaboration), into the experimental environment of storage rings at GSI, Darmstadt,…
Achieving high quantum efficiency (QE) with low dark count is essential for highly sensitive photodetectors (PDs), including single photon avalanche detectors (SPADs). However, high QE requires a thicker absorber region, which leads to high…
Particle IDentification (PID) is a central requirement of the experiments at the future EIC. Hadron PID at high momenta by RICH techniques requires the use of low density gaseous radiators, where the challenge is the limited length of the…
Arrays of hundreds or thousands of low temperature detectors have been deployed for many experiments, both bolometers for long wavelength applications and calorimeters for shorter wavelength applications. One challenge that is common to…
Next generation multi-ton scale noble liquid experiments have the unique opportunity to discover dark matter particles at the TeV scale, reaching the sensitivity of 10^-48 cm2 in the WIMP nucleon scattering cross-section. A prerequisite…
A none conventional approach for depth profiling of thin film systems with enhanced depth resolution has been developed using standard Auger microprobe instruments. For the preparation of an in situ low angle cross-section, the sample is…