Related papers: The 10 Tesla muSR instrument: detector solutions
Experiments at the future Electron Ion Collider require excellent hadron identification in a broad momentum range, in harsh conditions. A RICH capable to fulfill the PID requirements of the EIC could use MPGD-based photon detectors with…
The increasing concentration of greenhouse gases, notably CH4 and CO2, has fueled global temperature increases, intensifying concerns regarding the prevailing climate crisis. Effectively monitoring these gases demands a detector spanning…
We present observations of fields containing eight recently discovered binary millisecond pulsars using the telescopes at MDM Observatory. Optical counterparts to four of these systems are detected, one of which, PSR J2214+3000, is a novel…
The results of a 1-D Monte-Carlo program, which simulates the avalanche multiplication in diodes with depths of the order of 1 $\mu$m based on the method proposed in Ref.1, are presented. The aim of the study is to achieve a deeper…
We demonstrate very high resolution photon spectroscopy with a microwave-multiplexed two-pixel transition-edge sensor (TES) array. We measured a $^{153}$Gd photon source and achieved an energy resolution of 63 eV full-width-at-half-maximum…
The Multi-Blade is a Boron-10-based gaseous thermal neutron detector developed to face the challenge arising in neutron reflectometry at neutron sources. Neutron reflectometers are challenging instruments in terms of instantaneous counting…
A technique for measuring high-energy electrons using Si detectors of various thicknesses that are much smaller than the range of the examined electrons is presented. The advantages of the method are discussed on the basis of…
Owing to its high brilliance, infrared and terahertz synchrotron radiation (IR/THz-SR) has emerged as a powerful tool for spectroscopy under extreme (i.e., technically more difficult) experimental conditions such as high pressure, high…
Transition edge sensor (TES) microcalorimeters and bolometers are used for a variety of applications. The sensors are based on the steep temperature-dependent resistance of the normal-to-superconducting transition, and are thus…
The performance of a two-phase Ar avalanche detector with CsI photocathode was studied, with regard to potential application in coherent neutrino-nucleus scattering and dark matter search experiments. The detector comprised a 1 cm thick…
A state-of-the-art Resonant Inelastic X-ray Scattering (RIXS) facility, composed of a dedicated beamline and a 2D-RIXS spectrometer, has been constructed and commissioned at BL02U in NanoTerasu, Japan. This paper reports the optical design…
The international Muon Ionization Cooling Experiment (MICE) is being built, at the Rutherford Appleton Laboratory (RAL), to demonstrate the feasibility of ionization cooling of muon beams. This is one of the major technological steps needed…
We demonstrate a silicon photonic architecture comprised of Double Mach-Zehnder Interferometers (DMZIs) designed for high-contrast photonic applications. This configuration significantly enhances the achievable extinction ratio of photonic…
The Transition Edge Sensor is extremely sensitive to the change of temperature, combined with the high-Z metal of a certain thickness, it can realize the high energy resolution measurement of particles such as X-rays. X-rays with energies…
The availability of high-frequency pulsed emitters in the $2-2.5\,\mu$m wavelength range paved the way for a wealth of new applications in ultrafast spectroscopy, free-space and fiber-optical communications, surveillance and recognition,…
In this work we attempt to establish the best time resolution attainable with a scintillation counter consisting of a plastic scintillator read out by a Geiger-mode Avalanche Photodiode. The measured time resolution is inversely…
To date three plerionic systems have been detected as emitters of very energetic photons. As part of an ongoing study of pulsar systems at the Whipple observatory, observations of the plerion PSR B1823-13 are being conducted. Observations…
The previous article about material screening for GERDA points out the importance of strict material screening and selection for radioimpurities as a key to meet the aspired background levels of the GERDA experiment. This is directly done…
A novel concept for ion blocking in gas-avalanche detectors was developed, comprising cascaded micro-hole electron multipliers with patterned electrodes for ion defocusing. This leads to ion blocking at the 10^{-4} level, in DC mode, in…
As part of an experiment to measure the spectrum of photons emitted in beta-decay of the free neutron, we developed and operated a detector consisting of 12 bismuth germanate (BGO) crystals coupled to avalanche photodiodes (APDs). The…