Related papers: The 10 Tesla muSR instrument: detector solutions
We present the electro-thermal characterization of transition-edge sensor (TES) detectors suspended on Si membranes fabricated using a silicon-on-insulator (SOI) wafer. The use of an all-silicon fabrication platform, in contrast to the more…
We report on the design and performance of a near infra-red Mueller matrix imaging ellipsometer, and apply the instrument to strain imag- ing in near infra-red transparent solids. Particularly, we show that the instrument can be used to…
A high-granularity telescope system with a large sensitive area and low material budget has been developed for high-energy heavy ion beam tests. The telescope consists of nine layers of silicon microstrip detectors (SSDs), whose performance…
We demonstrate monolithically grown germanium-tin (GeSn) on silicon avalanche photodiodes (APDs) for infrared light detection. A relatively thinner Ge buffer design was adopted to allow effective photo carriers to transport from the GeSn…
The Spectral Energy Distribution (SED) mode of the Multiband Imaging Photometer for Spitzer (MIPS) Space Telescope provides low-spectral resolution (R ~ 15-25) spectroscopy in the far infrared using the MIPS 70 um detector. A reflective…
Large dynamic range room temperature photon number resolving (PNR) detectors can be very useful for measuring very low light intensities and for analyzing multiphoton quantum states. In this paper we present a PNR detector based on the…
The Zurich IMaging POLarimeter (ZIMPOL) developed at ETH Zurich and installed permanently at the Gregory Coude Telescope at Istituto Ricerche Solari Locarno (IRSOL) allows a polarimetric precision down to 10^-5 to be reached. This makes it…
Imperfections in integrated photonics manufacturing have a detrimental effect on the maximal achievable visibility in interferometric architectures. These limits have profound implications for further photonics technological developments…
The performances of THGEM multipliers in two-phase Xe avalanche mode are presented for the first time. Additional results on THGEM operation in gaseous Xe at cryogenic temperatures are provided. Stable operation of a double-THGEM multiplier…
In the framework of the upgrade of the Pierre Auger Observatory, a new high voltage module is being employed for the power supply of the 1-inch photomultiplier added to each water-Cherenkov detector of the surface array with the aim of…
We report a photon number resolving detector using two-dimensional electron gas (2DEG) based transistors. When the photon pulses impinge on the absorption region, the generated phonons dissipate ballistically in the 2DEG toward the trench…
Large-area next-generation physics experiments rely on using Silicon Photo-Multiplier (SiPM) devices to detect single photons, which trigger charge avalanches. The noise mechanism of external cross-talk occurs when secondary photons…
One important use of layered semiconductors such as molybdenum disulfide (MoS2) could be in making novel heterojunction devices leading to functionalities unachievable using conventional semiconductors. Here we demonstrate an ultrafast…
This paper presents results that take a critical step toward proving 10 ps timing resolution's feasibility for particle identification in the TOPSiDE detector concept for the Electron-Ion Collider. Measurements of LGADs with a thickness of…
The Multi-Blade is a Boron-10-based gaseous detector introduced to face the challenge arising in neutron reflectometry at pulsed neutron sources. Neutron reflectometers are the most challenging instruments in terms of instantaneous counting…
The Pixel Detector (PXD) of the Belle II experiment at superKEKB accelerator in Japan is based in the DEPFET technology. Two layers of 8+12 modules at a radius of 13 and 22 mm will give a spatial resolution below 10 mm. The radiation level…
The use of High Purity Germanium detectors operated in ionization mode at cryogenic temperatures is investigated as an external background mitigation solution for bolometers used in rare-event search experiments. A simple experimental setup…
The ambitious instrument suite for the future European Spallation Source whose civil construction started recently in Lund, Sweden, demands a set of diverse and challenging requirements for the neutron detectors. For instance, the…
A new apparatus, NA60+, is proposed for measuring muon pairs in the center-of-mass region from 5 to 17 GeV at CERN SPS in various collisional systems from Pb+Pb and down to $p$+Be. The physics scope of the new detector will cover topics…
This paper reports on the demonstration of a high-rate energy measurement technique using a thin depletion layer silicon avalanche photodiode (Si-APD). A dedicated amplitude-to-time converter is developed to realize simultaneous energy and…