Related papers: Detector with a profile-based cathode and a two-co…
The first successful attempts to optimize the electric field in Resistive Microstrip Gas Chamber and resistive microdot detectors using additional field shaping strips located inside the detector substrate are described
Large array gas detector systems are used in particle and nuclear physics experiments involving high-energy nucleon-nucleon and heavy-ion collisions. We have observed that in large array gas detector systems the momentary discharges inside…
We report on the construction and initial performance studies of two micromegas detector quadruplets with an area of 0.5 m$^2$. They serve as prototypes for the planned upgrade project of the ATLAS muon system. Their design is based on the…
We describe a work of a multi-cathode counter of the developed design in a single electron counting mode with a cathode made of aluminum alloy. The results of the calibration of the counter are presented. The coefficient of gas…
Detectability describes the property of a system whose current and the subsequent states can be uniquely determined after a finite number of observations. In this paper, we developed a novel approach to verifying strong detectability and…
Using simulations and analytical approaches, we have studied single hit resolutions obtained with a binary readout, which is often proposed for high granularity detectors to reduce the generated data volume. Our simulations considering…
In this paper we study the feasibility of an infrared detector based on intersubband transitions in the conduction band of the junction between two semiconductor quantum wires. We show that by varying the radius of the wires it is possible…
We have constructed and tested a 2d position sensitive parallel-plate gas ionization chamber with scanned charge transfer readout. The scan readout method described here is based on the development of a new position dependent charge…
In this paper, we address the problem of target detection in the presence of coherent (or fully correlated) signals, which can be due to multipath propagation effects or electronic attacks by smart jammers. To this end, we formulate the…
Although the anchor-based detectors have taken a big step forward in pedestrian detection, the overall performance of algorithm still needs further improvement for practical applications, \emph{e.g.}, a good trade-off between the accuracy…
A GEM tracking detector with an extended drift region has been studied as part of an effort to develop new tracking detectors for future experiments at RHIC and for the Electron Ion Collider that is being planned for BNL or JLAB. The…
This report summarizes work done during PhD rotation that proposes an algorithm that uses anode- cathode trigger time difference and cathode to anode pulse height ratio to resolve photon event positioning degeneracy in a novel Cadmium Zinc…
Various chips for the silicon sensors measurements are described. These chips are based on 0.35 um and 0.18um CMOS technology. Several analog chips together with self-trigger /derandomizer one allow to measure silicon sensors designed for…
Anomaly detection is a critical requirement for ensuring safety in autonomous driving. In this work, we leverage Cooperative Perception to share information across nearby vehicles, enabling more accurate identification and consensus of…
We present a new way of continuously reading-out the state of a single electronic spin. Our detection scheme is based on an exchange interaction between the electronic spin and a nearby read-out quantum dot. The coupling between the two…
The quest to improve transparent conductors balances two key goals: increasing electrical conductivity and increasing optical transparency. To improve both simultaneously is hindered by the physical limitation that good metals with high…
A new family of spark-protected micropattern gaseous detectors is introduced: a 2-D sensitive restive microstrip counter and hybrid detectors, which combine in one design a resistive GEM with a microstrip detector. These novel detectors…
The architecture of the novel MPGD-based photon detectors of COMPASS RICH-1 consists in a large-size hybrid MPGD multilayer layout combining two layers of Thick-GEMs and a bulk resistive MICROMEGAS. Concerning biasing voltage, the…
We developed a 2-mm-thick CdTe double-sided strip detector (CdTe-DSD) with a 250 um strip pitch, which has high spatial resolution with a uniform large imaging area of 10 cm$^2$ and high energy resolution with high detection efficiency in…
We report on the design, production, and testing of advanced double-sided silicon strip detectors under development at the Max-Planck-Institute as part of the Medium Energy Gamma-ray Astronomy (MEGA) project. The detectors are designed to…