Related papers: Horizontal Test for BEPCII 500MHz Spare Cavity
A low loss (LL) type 500 MHz 5-cell superconducting niobium prototype cavity with large beam aperture has been developed successfully including the optimization, the deep drawing and electron beam welding, the surface treatment and the…
A 325MHz beta=0.14 superconducting half wave resonator(HWR) prototype has been developed at the Institute of High Energy Physics(IHEP), which can be applied in continuous wave (CW) high beam proton accelerators. In this paper, the…
Hundreds of 650 MHz superconducting radio-frequency (SRF) cavities with high intrinsic quality factor (Q0) and accelerating gradient (Eacc) will be adopted for Circular Electron Positron Collider (CEPC). The values of Q0 and Eacc are…
We first introduce the design parameters of the Beijing Electron-Positron Collider II (BEPCII) and the simulation study of beam-beam effects during the design process of the machine. The main advances since 2007 are briefly introduced and…
The g2p/GEp experiments used a solid NH3 polarized target, where the polarization of the target is sensitive to temperature and radiation. The beam current was limited to 5-100 nA during the experiment to avoid too much depolarization of…
We present a measurement of the time-dependent charge-parity (CP) violation parameters in B0 -> pi+ pi- decays. The results are obtained from the final data sample containing 772 million BBbar pairs collected at the Upsilon(4S) resonance…
The Status of BEPCII/BESIII upgrade is described, BEPCII is designed to reach a luminosity of $10^{33}/cm^{-2}s^{-1}$ at c. m. energy of 3.89GeV, and BESIII detector is fully rebuilt. The project is on track and is progressing well. The…
We present updated measurements of the CP-violating parameters S_pipi and C_pipi in B0 -> pi+pi- decays. Using a sample of 227 million Y(4S) -> BBbar decays collected with the BaBar detector at the PEP-II asymmetric-energy e+e- collider at…
Precision beam polarization measurements based on Compton polarimeters are essential for the physics program of future high-energy colliders. In order to prepare for these and to extend the scope of physics measurements of the BESIII…
A new bunch length measurement method based on high order mode cavity was proposed. Operating the harmonic cavity at mode TM0n0 so that its radius could be chosen, in order to break the limitation of beam pipe radius. A two-cavity bunch…
It is proposed to upgrade the endcap time-of-flight (ETOF) of the Beijing Spectrometer III (BESIII) with multi-gap resistive plate chamber (MRPC), aiming at overall time resolution about 80 ps. After the entire electronics system is ready,…
Using 58 million J/psi decays obtained by BESII, a charged kappa particle is observed in the analysis of the Kspi+- system recoiling against K*(892)-+ selected in J/psi -> KsKspi+pi-. The mass and width values of the charged kappa are…
We report improved measurements of the partial rate asymmetry (Acp) in B -> h h decays with 140fb^-1 of data collected with the Belle detector at the KEKB e+e- collider. Here h stands for a charged or neutral pion or kaon and in total five…
This paper present high precision halfwave rectifier circuit in dual phase output mode by 0.5 micrometer CMOS technology, plus or minus 1.5 V low voltage, it has received input signal and sent output current signal, respond in high…
New measurements of neutral and charged current cross sections at large negative four-momentum transfer squared Q^2 have been performed by H1 and ZEUS, using up to the complete HERA II ep data, which was taken with polarised electron and…
A high-power liquid hydrogen target was built for the Jefferson Lab Qweak experiment, which measured the tiny parity-violating asymmetry in $\vec{e}$p scattering at an incident energy of 1.16 GeV, and a Q$^2 = 0.025$ GeV$^{2}$. To achieve…
The upgrade of the ISOLDE machine at CERN foresees a superconducting linac based on two gap independently phased Nb sputtered Quarter Wave Resonators (QWRs) working at 101.28MHz and producing an accelerating field of 6MV/m on axis. A…
The interrogation of an ultra-narrow clock transition of a single trapped ion for optical frequency metrology requires a laser stabilized to a couple of Hz per second with a linewidth of the same order of magnitude. Today, lasers in the…
Using $2.93~\mathrm{fb}^{-1}$ of $e^+e^-$ annihilation data collected at a center-of-mass energy $\sqrt{s}=3.773$ GeV with the BESIII detector operating at the BEPCII collider, we search for the semileptonic $D^{0(+)}$ decays into a…
The pseudogap phase above the critical temperature of high $T_{c}$ superconductors (HTSC) presents different energy scales and it is currently a matter of intense study. The complexity of the HTSC normal state requires very accurate…