English
Related papers

Related papers: A liquid xenon TPC for a medical imaging Compton t…

200 papers

A prototype of the MeV gamma-ray imaging camera based on the full reconstruction of the Compton process has been developed. This camera consists of a micro-TPC that is a gaseous Time Projection Chamber (TPC) and scintillation cameras. With…

We describe a feasible implementation of a novel X-ray detector for highly energetic x-ray photons with a large solid angle coverage, optimal for the detection of Compton x-ray scattered photons. The device consists of a 20~cm-thick…

Instrumentation and Detectors · Physics 2022-01-27 Ángela Saá Hernández , Diego González-Díaz , Pablo Villanueva , Carlos Azevedo , Marcos Seoane

The design and performance of a 1.2 liter liquid xenon chamber equipped with 7 two-inch photomultiplier tubes, with the purpose of studying the scintillation response of xenon to gamma-rays and neutrons, is described. Measurements with…

Modern PET systems reach a spatial resolution of 3-10 mm. A disadvantage of this technique is the diffusion of the positron before its decay with a typical range of ca. 1 mm (depending on its energy). This motion and Compton scattering of…

Instrumentation and Detectors · Physics 2012-02-03 C. Lang , D. Habs , P. G. Thirolf , A. Zoglauer

PET is a functional imaging technique based on detection of annihilation photons following beta decay producing positrons. In this paper, we present the concept of a new PET system for preclinical applications consisting of a ring of twelve…

Instrumentation and Detectors · Physics 2015-03-19 A. Miceli , P. Amaudruz , F. Benard , D. A. Bryman , L. Kurchaninov , J. P. Martin , A. Muennich , F. Retiere , T. J. Ruth , V. Sossi , A. J. Stoessl

We report on a new measurement of the energy resolution that can be attained in liquid xenon when recording only the scintillation light. Our setup is optimized to maximize light collection, and uses state-of-the-art, high-PDE,…

An 800L liquid xenon scintillation $\gamma$ ray detector is being developed for the MEG experiment which will search for $\mu^+\to\mathrm{e}^+\gamma$ decay at the Paul Scherrer Institut. Absorption of scintillation light of xenon by…

The detection of photons with energies greater than a few tenths of an MeV, interacting via Compton scattering and/or pair production, faces a number of difficulties. The reconstruction of single-scatter Compton events can only determine…

Instrumentation and Methods for Astrophysics · Physics 2023-04-05 Denis Bernard , Stanley D. Hunter , Toru Tanimori

We report the design, construction, and initial commissioning results of a large high pressure gaseous Time Projection Chamber (TPC) with Micromegas modules for charge readout. The detector vessel has an inner volume of about 600 L and an…

The goal of the Medium Energy Gamma-ray Astronomy (MEGA) telescope is to improve sensitivity at medium gamma-ray energies (0.4-50 MeV) by at least an order of magnitude over that of COMPTEL. This will be achieved with a new compact design…

Astrophysics · Physics 2019-08-14 P. F. Bloser , R. Andritschke , G. Kanbach , V. Schoenfelder , F. Schopper , A. Zoglauer

The imaging performance of a high-resolution preclinical microPET system employing liquid xenon as the gamma ray detection medium was simulated. The arrangement comprises a ring of detectors consisting of trapezoidal LXe time projection…

Medical Physics · Physics 2012-03-23 A. Miceli , J. Glister , A. Andreyev , D. Bryman , L. Kurchaninov , P. Lu , A. Muennich , F. Retiere , V. Sossi

We have been developing a high-pressure xenon gas time projection chamber (TPC) to search for neutrinoless double beta ($0\nu\beta\beta$) decay of $^{136}$Xe. The unique feature of this TPC is in the detection part of ionization electrons,…

The Time Projection Chamber (TPC) is an ideal candidate to finely study the charged particle ionization in a gaseous medium. Large volumes TPCs can be read out with a suitable number of channels offering a complete 3D reconstruction of an…

Study of high energy cosmic events in the MeV range requires detector with high efficiency and energy resolution to be constructed. The present setup consisting of scintillator crystals CeBr3 with different thickness, each coupled with 12 x…

Instrumentation and Detectors · Physics 2025-12-10 Veronika Asova , Galin Bistrev , Simeon Ivanov

A Compton camera is the most promising approach for gamma-ray detection in the energy region from several hundred keV to MeV, especially for application in high energy astrophysics. In order to obtain good angular resolution, semiconductor…

Compton scattering of photons off high-energy electrons is a fundamental quantum mechanical process widely utilized to produce a $\gamma$-ray beam for scientific research. Instead of injecting laser light into a storage ring as a…

Results from the simulations of a Compton gamma camera based on compact configuration of detectors consisting in two detection modules, each of them having two stages of high-resolution position- and energy-sensitive radiation detectors…

Medical Physics · Physics 2018-02-15 L. Caballero

Tomographic imaging with radionuclides commonly used in nuclear medicine, such as $^{111}$In (171 and 245 keV) and $^{131}$I (364 keV), is in high demand for medical applications and small animal imaging. The Si/CdTe Compton camera with its…

A new method for measuring \ngr cross sections aiming at enhanced signal-to-background ratio is presented. This new approach is based on the combination of the pulse-height weighting technique with a total energy detection system that…

Instrumentation and Detectors · Physics 2015-10-15 César Domingo-Pardo

The GammaTPC is an MeV-scale single-phase liquid argon time-projection-chamber gamma-ray telescope concept with a novel dual-scale pixel-based charge-readout system. It promises to enable a significant improvement in sensitivity to…

Instrumentation and Methods for Astrophysics · Physics 2023-01-25 M. Buuck , A. Mishra , E. Charles , N. Di Lalla , O. Hitchcock , M. E. Monzani , N. Omodei , T. Shutt