English
Related papers

Related papers: A time-resolution study with a plastic scintillato…

200 papers

Multi-Pixel Photon Counters (MPPC) consist of hundreds of micro silicon Avalanche PhotoDiodes (APD) working in Geiger mode. The high gain and the low noise, typical of these devices, together with their good performance in magnetic field,…

Instrumentation and Detectors · Physics 2019-03-08 A. Scordo , M. Bazzi , C. Berucci , C. Curceanu , A. D'Uffizi , K. Piscicchia , M. Poli Lener , A. Romero Vidal , E. Sbardella , O. Vazquez Doce

Photosensitive gaseous detectors with a simple photoelectron multiplication mechanism of resistive plate chambers (RPCs) are expected to have both a large photocoverage and an excellent time resolution and to be low-cost. To demonstrate the…

Instrumentation and Detectors · Physics 2023-05-24 K. Matsuoka , R. Okubo , Y. Adachi

We have developed a photon counting detector system for combined neutron and gamma radiography which can determine position, time and intensity of a secondary photon flash created by a high-energy particle or photon within a scintillator…

Major advances in silicon pixel detectors, with outstanding timing performance, have recently attracted significant attention in the community. In this work we present and discuss the use of state-of-the-art Geiger-mode APDs, also known as…

We demonstrate a single-photon sensitive spectrometer in the visible range, which allows us to perform time-resolved and multi-photon spectral correlation measurements. It is based on a monochromator composed of two gratings, collimation…

This paper reports on the demonstration of a high-rate energy measurement technique using a thin depletion layer silicon avalanche photodiode (Si-APD). A dedicated amplitude-to-time converter is developed to realize simultaneous energy and…

Instrumentation and Detectors · Physics 2018-11-05 T. Masuda , T. Hiraki , H. Kaino , S. Kishimoto , Y. Miyamoto , K. Okai , S. Okubo , R. Ozaki , N. Sasao , K. Suzuki , S. Uetake , A. Yoshimi , K. Yoshimura

Photon number resolving detectors are needed for a variety of applications including linear-optics quantum computing. Here we describe the use of time-multiplexing techniques that allows ordinary single photon detectors, such as silicon…

Quantum Physics · Physics 2007-05-23 M. J. Fitch , B. C. Jacobs , T. B. Pittman , J. D. Franson

We describe a detector for measuring the time of flight of forward protons at the Large Hadron Collider (LHC) up to and beyond the full instantaneous design luminosity of 1034 cm-2 s-1. Our design is based on deep diffused, high gain…

Instrumentation and Detectors · Physics 2009-01-19 Sebastian White , Mickey Chiu , Milind Diwan , Grigor Atoian , Vladimir Issakov

Ultra-Fast Silicon Detectors (UFSDs) are n-in-p silicon detectors that implement moderate gain (typically 5 to 25) using a thin highly doped p++ layer between the high resistivity p-bulk and the junction of the sensor. The presence of gain…

The scintillating properties of active materials used in high energy and particle physics experiments play an important role regarding the performances of both calorimeters and experiments. Two scintillator materials, a scintillating glass…

Instrumentation and Detectors · Physics 2018-09-11 Güral Aydın

The photon detection efficiencies of multi-pixel Geiger-mode avalanche photodiodes manufactured by different produ cers are estimated. A new fit method of the response spectra to low-intensity light, taking into ac count after-pulse and…

Instrumentation and Detectors · Physics 2010-06-17 Simonetta Gentile , Ekaterina Kuznetsova , Franco Meddi

A monolithic silicon pixel detector prototype has been produced in the SiGe BiCMOS SG13G2 130 nm node technology by IHP. The ASIC contains a matrix of hexagonal pixels with pitch of approximately 100 $\mu$m. Three analog pixels were…

In this short note we present results of background measurements carried out with a polystyrene based cast plastic 12.0x12.0x3.0 cm^3 size scintillator counter with a wavelength shifting fibre and a multi-pixel Geiger mode avalanche…

In recent years, a number of purpose-built scintillator-based polarimeters have studied bright astronomical sources for the first time in the hard X-ray band (tens to hundreds of keV). The addition of polarimetry can help data…

Instrumentation and Methods for Astrophysics · Physics 2019-08-08 Rakhee Kushwah , Nirmal K. Iyer , Mózsi Kiss , Theodor A. Stana , Mark Pearce

To meet the stringent time calibration requirements for the Belle II experiment upgrade, particularly for its large-size KL and Muon Detector comprising tens of thousands of scintillator channels with time resolutions better than 100 ps, we…

Instrumentation and Detectors · Physics 2026-02-23 Ziyu Liu , Xiyang Wang , Shiming Zou , Xiaolong Wang , Junhao Yin , Minggang Zhao

A second monolithic silicon pixel prototype was produced for the MONOLITH project. The ASIC contains a matrix of hexagonal pixels with 100 {\mu}m pitch, readout by a low-noise and very fast SiGe HBT frontend electronics. Wafers with 50…

Liquid xenon offers several features, which make it suitable for applications in nuclear medicine, such as high scintillation yield and fast scintillation decay time. Moreover, being a continuous medium with a uniform response, liquid xenon…

Instrumentation and Detectors · Physics 2021-03-02 Carmen Romo-Luque

We propose a new scintillation-type detector in which high-energy radiation produces electron-hole pairs in a direct-gap semiconductor material that subsequently recombine producing infrared light to be registered by a photo-detector. The…

Instrumentation and Detectors · Physics 2009-11-13 A. Kastalsky , S. Luryi , B. Spivak

Measurement of the Time-of-Flight (TOF) of the 511 keV gammas brings an important reduction of statistical noise in the PET image, with higher precision time measurements producing clearer images. Scintillating crystals are used to convert…

Instrumentation and Detectors · Physics 2019-12-03 K. Doroud , Z. Liu , M. C. S. Williams

The energy and electric field dependence of pulse shape discrimination in liquid xenon have been measured in a 10 gm two-phase xenon time projection chamber. We have demonstrated the use of the pulse shape and charge-to-light ratio…

Instrumentation and Methods for Astrophysics · Physics 2015-05-13 J. Kwong , P. Brusov , T. Shutt , C. E. Dahl , A. I. Bolozdynya , A. Bradley
‹ Prev 1 3 4 5 6 7 10 Next ›