English
Related papers

Related papers: Experimental study of THGEM detector with mini-rim

200 papers

The design of multi-channel gas electron multiplier (MGEM) with metallic electrodes is proposed, produced and tested. The electrodes of MGEM are produced from the brass plates with thickness of 1 mm, round openings of 1 mm in diameter and…

Instrumentation and Detectors · Physics 2010-06-17 B. M. Ovchinnikov , V. V. Parusov , Yu. B. Ovchinnikov

Gas electron multipliers (GEMs) with wire (WGEMs) or metal electrodes (MGEMs), which don't use any plastic insulators between the electrodes are created. The absence of plastic insulation between the electrodes of WGEMs excludes unwanted…

Instrumentation and Detectors · Physics 2020-06-12 B. M. Ovchinnikov , V. V. Parusov

The use of gaseous Time Projection Chambers enables the detection and the detailed study of rare events due to particles interactions with the atoms of the gas with energy releases as low as a few keV. Due to this capability, these…

A large volume time projection chamber (TPC) has been proposed as main tracking device for a detector at a future linear e+e- collider. Gas electron multipliers (GEMs) are studied as potential replacement of the conventional wire based gas…

Instrumentation and Detectors · Physics 2007-05-23 Peter Wienemann

To extend the acceptance of the CMS muon spectrometer to the region 2.4 $<|\eta|<$ 2.8, stacks of triple-GEM chambers, forming the ME0 station, are planned for the CMS Phase 2 Upgrade. These large-area micro-pattern gaseous detectors must…

We report promising initial results obtained with new resistive-electrode GEM (RETGEM) detectors manufactured, for the first time, using screen printing technology. These new detectors allow one to reach gas gains nearly as high as with…

Instrumentation and Detectors · Physics 2009-12-10 B. Clark , A. G. Agocs , R. Oliveira , V. Peskov , Pietropaolo , Picchi

A new thermal neutron detector with the domestically produced THGEM (THick Gas Electron Multiplier) was developed as an alternative to 3He to meet the needs of the next generation of neutron facilities. One type of Au-coated THGEM was…

Instrumentation and Detectors · Physics 2014-08-06 Yang Lei , Zhou Jian-Rong , Sun Zhi-Jia , Zhang Ying , Huang Chao-Qiang , Sun Guang-Ai , Wang Yan-Feng , Yang Gui-An , Xu Hong , Xie Yu-Guang , Chen Yuan-Bo

We present the results of first studies of the Resistive Plate WELL (RPWELL): a single-faced THGEM coupled to a copper anode via a resistive layer of high bulk resistivity. We explored various materials of different bulk resistivity (10^9 -…

Instrumentation and Detectors · Physics 2015-06-17 A. Rubin , L. Arazi , S. Bressler , L. Moleri , M. Pitt , A. Breskin

A micro time-projection-chamber (micro-TPC) with a detection volume of 23*28*31 cm^3 was developed, and its fundamental performance was examined. The micro-TPC consists of a micro pixel chamber with a detection area of 31*31 cm^2 as a…

The requirement of a large number of electronic channels poses a big challenge for Micro-pattern Gas Detector (MPGD) to achieve good spatial resolution. By using the redundancy that at least two neighboring strips record the signal of a…

Instrumentation and Detectors · Physics 2016-08-03 Bin-Xiang Qi , Shu-Bin Liu , Heng Ji , Zhong-Tao Shen , Si-Yuan Ma , Hong-Bang Liu , Wen-Qian Huang , Qi An

Low pressure gaseous Negative Ion Time Projection Chambers (NITPCs) have been used previously by the DRIFT experiment to search for a directional Dark Matter (DM) signature. The main challenge with using a Negative Ion Drift (NID) gas…

Instrumentation and Detectors · Physics 2026-02-16 A. G. McLean , S. Higashino , R. R. Marcelo Gregorio , K. Miuchi , N. J. C. Spooner

Micro-pattern gas detectors (MPGDs) are widely utilized in physics experiments owing to their excellent spatial resolution and high-rate capabilities. Within the PandaX-III experiment, which aims to investigate neutrinoless double beta…

Instrumentation and Detectors · Physics 2025-12-09 Yunzhi Peng , Yuanchun Liu , Zhiyong Zhang , Shaobo Wang , Jianbei Liu , Ming Shao , Yi Zhou

In 2008, a triple GEM detector prototype with an area of ~2000 cm2 has been constructed, based on foils of 66*66 cm. GEMs of such dimensions had not been made before, and innovations to the existing technology were introduced to build this…

An innovative photosensitive gaseous detector, consisting of a GEM like amplification structure with double layered electrodes (instead of commonly used metallic ones) coated with a CsI reflective photocathode, is described. In one of our…

Instrumentation and Detectors · Physics 2008-07-18 V. Peskov , P. Martinengo , E. Nappi , R. Oliveira , G. Paic , F. Pietropaolo , P. Picchi

The operating principle and performances of the Multi-layer Thick Gaseous Electron Multiplier (M-THGEM) is presented. The M-THGEM is a novel hole-type gaseous electron multiplier produced by multi-layer printed circuit board technology; it…

Instrumentation and Detectors · Physics 2016-06-24 M. Cortesi , S. Rost , W. Mittig , Y. Ayyad Limonge , D. Bazin , J. Yurkon , A. Stolz

The main aim of the study is to perform the long-term stability test of gain of the single mask triple GEM detector. A simple method is used for this long- term stability test using a radioactive X-ray source with high activity. The test is…

Instrumentation and Detectors · Physics 2016-11-03 R. P. Adak , S. Biswas , S. Das , D. Ghosal , S. K. Ghosh , A. Mondal , D. Nag , T. K. Nayak , R. N. Patra , S. K Prasad , S. Raha , P. K. Sahu , S. Sahu , S. Swain

In this paper, a detailed investigation has been carried out to understand the physics behind GEM charging-up and its effects on gain. Experiments have been performed on both double and triple GEM with the help of 55Fe X-ray source and a…

Instrumentation and Detectors · Physics 2022-07-13 Vishal Kumar , Supratik Mukhopadhyay , Nayana Majumdar , Sandip Sarkara

In recent years, the progress on low temperature detector technologies has allowed design of large scale experiments aiming at pushing down the sensitivity on the neutrino mass below 1\,eV. Even with outstanding performances in both energy…

The latest Micromesh Gas Amplification Structures (Micromegas) are achieving outstanding energy resolution for low energy photons, with values as low as 11% FWHM for the 5.9 keV line of $^{55}$Fe in argon/isobutane mixtures at atmospheric…

Instrumentation and Detectors · Physics 2015-05-13 T. Dafni , E. Ferrer-Ribas , I. Giomataris , Ph. Gorodetzky , F. Iguaz , I. G. Irastorza , P. Salin , A. Tomas

Gaseous detectors are used in high energy physics as trackers or, more generally, as devices for the measurement of the particle position. For this reason, they must provide high spatial resolution and they have to be able to operate in…