English
Related papers

Related papers: Blackbody radiation shift in 87Rb frequency standa…

200 papers

In this paper we report the development of the design verification model (DVM) of Rb atomic frequency standard. The Rb atomic frequency standard or clock has two distinct parts. One is the Physics Package where the hyperfine transitions…

Instrumentation and Detectors · Physics 2012-02-02 Bikash Ghosal , Sarathi Mandal , Satish Nandanwar , S. S. Raghuwanshi , Savita Singh , R. K. Bahl , A. Banik , K. S. Dasgupta , G. M. Saxena

The bound beta-decay (BoB) of neutron is also known as the two-body neutron decay, which is a rare decay mode into a hydrogen atom and an anti-neutrino. The state of neutrino can be exactly inferred by measuring the state of hydrogen atom,…

High Energy Physics - Experiment · Physics 2023-04-20 Zhang Shuo , Xavier Mougeot , Wang Song-Lin , Zhou Jian-Rong , Wu Wen-Tao , Xia Jing-Kai , Zhang Rui-Tian , Zhang Le

Optical atomic clocks are poised to redefine the SI second, thanks to stability and accuracy more than one hundred times better than the current microwave atomic clock standard. However, the best optical clocks have not seen their…

We demonstrate a novel scheme for Raman-pulse and Bragg-pulse atom interferometry based on the $5\mathrm{S} - 6\mathrm{P}$ blue transitions of $^{87}$Rb that provides an increase by a factor $\sim 2$ of the interferometer phase due to…

Atomic Physics · Physics 2023-07-31 L. Salvi , G. M. Tino , L. Cacciapuoti , G. Rosi

Using optical Ramsey interferometry, we precisely measure the laser-induced AC-stark shift on the $S_{1/2}$ -- $D_{5/2}$ "quantum bit" transition near 729 nm in a single trapped $^{40}$Ca$^+$ ion. We cancel this shift using an additional…

Atomic Physics · Physics 2016-09-08 H. Haeffner , S. Gulde , M. Riebe , G. Lancaster , C. Becher , J. Eschner , F. Schmidt-Kaler , R. Blatt

We search for ultralight scalar dark matter candidates that induce oscillations of the fine structure constant, the electron and quark masses, and the quantum chromodynamics energy scale with frequency comparison data between an $^{171}$Yb…

We report the absolute frequency measurement of the 5s2 1S0-5s5p 3P0 transition in 87Sr optical lattice clock (Sr1) at National Time Service Center (NTSC). Its systematic frequency shifts are evaluated carefully with a total relative…

Atomic Physics · Physics 2023-02-01 Xiaotong Lu , Feng Guo , Yebing Wang , Qinfang Xu , Chihua Zhou , Jingjing Xia , Wenjun Wu , Hong Chang

Time-resolved spectroscopy is performed on eight bright, long gamma-ray bursts (GRBs) dominated by single emission pulses that were observed with the {\it Fermi Gamma-ray Space Telescope}. Fitting the prompt radiation of GRBs by empirical…

We demonstrate that several metastable excited states in Hf$~$II, Hf$~$IV and W$~$VI ions may be good clock states since they are sufficiently long-living and are not sensitive to the perturbations. Cooling E1 transitions are available.…

Atomic Physics · Physics 2022-09-20 Saleh O. Allehabi , V. A. Dzuba , V. V. Flambaum

We study the prospects of using transitions from the ytterbium ground state to metastable states $^3{\rm P}^{\rm o}_2$ at $E=19\,710.388~$cm$^{-1}$ and $4f^{13}5d6s^2\,(J=2)$ at $E=23\,188.518~$cm$^{-1}$ as clock transitions in an optical…

Atomic Physics · Physics 2018-08-22 V. A. Dzuba , V. V. Flambaum , S. Schiller

We present precise values of the dipole polarizabilities ($\alpha$) of the ground $\rm [4f^{14}6s] ~ ^2S_{1/2}$ and metastable $\rm [4f^{14} 5d] ~ ^2D_{3/2}$ states of Yb$^+$, that are %vital {\bf important} in reducing systematics in the…

Atomic Physics · Physics 2017-10-25 A. Roy , S. De , Bindiya Arora , B. K. Sahoo

We report a combined theoretical and experimental study of the spectral and polarization dependence of near resonant radiation coherently backscattered from an ultracold gas of 85Rb atoms. Measurements in an approximately 6 MHz range about…

Quantum Physics · Physics 2009-11-10 D. V. Kupriyanov , I. M. Sokolov , N. V. Larionov , P. Kulatunga , C. I. Sukenik , S. Balik , M. D. Havey

We demonstrate control of the differential Zeeman shift between clock states of ultracold rubidium atoms by means of non-resonant microwave dressing. Using the dc-field dependence of the microwave detuning, we suppress the first and second…

Atomic Physics · Physics 2017-07-13 L. Sárkány , P. Weiss , H. Hattermann , J. Fortágh

Ultracold hybrid ion-atom traps offer the possibility of microscopic manipulation of quantum coherences in the gas using the ion as a probe. However, inelastic processes, particularly charge transfer can be a significant process of ion loss…

Atomic Physics · Physics 2015-06-19 B. M. McLaughlin , H. D. L. Lamb , I. C. Lane , J. F. McCann

We have computed the black body radiation spectra in $\kappa-$Minkowski space-time, using the quantum mechanical picture of massless scalar particles as well as effective quantum field theory picture. The black body radiation depends on how…

High Energy Physics - Theory · Physics 2008-11-26 Hyeong-Chan Kim , Chaiho Rim , Jae Hyung Yee

We study the $^1$S$_0 - ^3$D$_2$ and $^1$S$_0 - ^3$D$_3$ transitions in Cu II and the $^1$S$_0 - ^3$P$^{\rm o}_2$ transition in Yb III as possible candidates for the optical clock transitions. A recently developed version of the…

Atomic Physics · Physics 2021-12-14 Saleh O. Allehabi , V. A. Dzuba , V. V. Flambaum

We utilize the dark state in a {\Lambda}-type three-level system to cool an ensemble of 85Rb atoms in an optical lattice [Morigi et al., Phys. Rev. Lett. 85, 4458 (2000)]. The common suppression of the carrier transition of atoms with…

Atomic Physics · Physics 2021-01-13 Chang Huang , Shijie Chai , Shau-Yu Lan

Using a single trapped barium ion we have developed an rf spectroscopy technique to measure the ratio of the off-resonant vector ac Stark effect (or light shift) in the 6S_{1/2} and 5D_{3/2} states to 0.1% precision. We find R = Delta_S /…

Atomic Physics · Physics 2016-09-08 J. A. Sherman , T. W. Koerber , A. Markhotok , W. Nagourney , E. N. Fortson

Optical lattice clocks are at the forefront of frequency metrology. Both the instability and systematic uncertainty of these clocks have been reported to be two orders of magnitude smaller than the best microwave clocks. For this reason, a…