English
Related papers

Related papers: Silicon photomultiplier timing performance study

200 papers

Silicon photomultipliers are photon sensors based on an array of pixels, each consisting of a single photon avalanche photodiode (SPAD). Reading of the array is not done on a single-pixel basis, but all pixels are read simultaneously.…

Instrumentation and Detectors · Physics 2024-03-13 Valerio Bocci

The motivation of the current R&D project is based upon the requirements of the JEDI international collaboration aiming to measure Electric Dipole Moments (EDMs) of charged particles in storage rings. One of the most important elements of…

The crosstalk and afterpulsing in Hamamatsu silicon photomultipliers, called Multi-Pixel Photon Counters (MPPCs), have been studied in depth. Several components of the correlated noise have been identified according to their different…

Instrumentation and Detectors · Physics 2015-10-22 Jaime Rosado , Salvador Hidalgo

Hamamatsu Photonics introduced a new generation of their Multi-Pixel Photon Counters in 2013 with significantly reduced after-pulsing rate. In this paper, we investigate the causes of after-pulsing by testing pre-2013 and post-2013 devices…

Instrumentation and Detectors · Physics 2017-09-13 Kyle Boone , Yuji Iwai , Fabrice Retiere , Carl Rethmeier

A large area Resistive Plate Chamber (RPC) with a total active surface of 160x10 cm2 was built and tested. The surface was segmented in two 5 cm wide strips readout on both ends with custom, very high frequency, front end electronics. A…

Instrumentation and Detectors · Physics 2009-11-07 A. Blanco , R. Ferreira-Marques , Ch. Finck , P. Fonte , A. Gobbi , A. Policarpo , M. Rozas

This paper describes the experience with the calibration, reconstruction and evaluation of the timing capabilities of the CMS HGCAL prototype in the beam tests in 2018. The calibration procedure includes multiple steps and corrections…

Instrumentation and Detectors · Physics 2024-04-15 CMS HGCAL collaboration

Conventional silicon photomultipliers (SiPMs) are well established as light detectors with single-photon-detection capability and used throughout high energy physics, medical, and commercial applications. The possibility to produce single…

In this paper, different Silicon PhotoMultiplier (SiPM) sensors have been tested with charged particles to characterize the Cherenkov light produced in the sensor protection layer. A careful position scan of the SiPM response has been…

Multi-Pixel Photon Counters (MPPC) consist of hundreds of micro silicon Avalanche PhotoDiodes (APD) working in Geiger mode. The high gain and the low noise, typical of these devices, together with their good performance in magnetic field,…

Instrumentation and Detectors · Physics 2019-03-08 A. Scordo , M. Bazzi , C. Berucci , C. Curceanu , A. D'Uffizi , K. Piscicchia , M. Poli Lener , A. Romero Vidal , E. Sbardella , O. Vazquez Doce

Detectors inherently capable of resolving photon numbers have undergone a significant development recently, and this is expected to affect multiplexed periodic single-photon sources where such detectors can find their applications. We…

Quantum Physics · Physics 2020-07-29 Ferenc Bodog , Matyas Mechler , Matyas Koniorczyk , Peter Adam

Gamma-ray observations in the very-high-energy domain (E > 30 GeV) can exploit the imaging of few-nanosecond Cherenkov flashes from atmospheric particle showers. Photomultipliers have been used as the primary photosensors to detect…

Instrumentation and Methods for Astrophysics · Physics 2019-08-14 Jonathan Biteau , David Chinn , Dennis Dang , Kevin Doyle , Caitlin A. Johnson , David A. Williams

Silicon photomultipliers (SiPMs) will be used to read out all calorimeters in the ePIC experiment at the Electron-Ion Collider (EIC). A thorough characterization of the radiation damage expected for SiPMs under anticipated EIC fluences is…

Instrumentation and Detectors · Physics 2025-06-23 Jiajun Huang , Sean Preins , Ryan Tsiao , Miguel Rodriguez , Barak Schmookler , Miguel Arratia

Radon is the main background source of dark matter and neutrino experiments. Radon concentration ($\rm mBq/m^3$) measurement by liquid scintillation detector is a highly sensitive method at low temperatures using silicon photomultipliers…

Instrumentation and Detectors · Physics 2022-11-23 C. Zhong , F. J. Luo , B. Zheng , X. D. Wang , M. Y. Bu , J. Zou , M. N. Deng

The current understanding of radiation tollerance of Silicon Photomultipliers (SiPMs) is reviewd. Radiation damage in silicon sensors is briefly introduced, surface and bulk effects are separately addressed. Results on the operation of…

Instrumentation and Detectors · Physics 2019-05-01 E. Garutti , Yu. Musienko

Procedures and results on hardware level detector calibration in Super-Kamiokande (SK) are presented in this paper. In particular, we report improvements made in our calibration methods for the experimental phase IV in which new readout…

Instrumentation and Detectors · Physics 2013-12-23 K. Abe , Y. Hayato , T. Iida , K. Iyogi , J. Kameda , Y. Kishimoto , Y. Koshio , Ll. Marti , M. Miura , S. Moriyama , M. Nakahata , Y. Nakano , S. Nakayama , Y. Obayashi , H. Sekiya , M. Shiozawa , Y. Suzuki , A. Takeda , Y. Takenaga , H. Tanaka , T. Tomura , K. Ueno , R. A. Wendell , T. Yokozawa , T. J. Irvine , H. Kaji , T. Kajita , K. Kaneyuki , K. P. Lee , Y. Nishimura , K. Okumura , T. McLachlan , L. Labarga , E. Kearns , J. L. Raaf , J. L. Stone , L. R. Sulak , S. Berkman , H. A. Tanaka , S. Tobayama , M. Goldhaber , K. Bays , G. Carminati , W. R. Kropp , S. Mine , A. Renshaw , M. B. Smy , H. W. Sobel , K. S. Ganezer , J. Hill , W. E. Keig , J. S. Jang , J. Y. Kim , I. T. Lim , N. Hong , T. Akiri , J. B. Albert , A. Himmel , K. Scholberg , C. W. Walter , T. Wongjirad , T. Ishizuka , S. Tasaka , J. G. Learned , S. Matsuno , S. N. Smith , T. Hasegawa , T. Ishida , T. Ishii , T. Kobayashi , T. Nakadaira , K. Nakamura , K. Nishikawa , Y. Oyama , K. Sakashita , T. Sekiguchi , T. Tsukamoto , A. T. Suzuki , Y. Takeuchi , K. Huang , K. Ieki , M. Ikeda , T. Kikawa , H. Kubo , A. Minamino , A. Murakami , T. Nakaya , M. Otani , K. Suzuki , S. Takahashi , Y. Fukuda , K. Choi , Y. Itow , G. Mitsuka , M. Miyake , P. Mijakowski , R. Tacik , J. Hignight , J. Imber , C. K. Jung , I. Taylor , C. Yanagisawa , Y. Idehara , H. Ishino , A. Kibayashi , T. Mori , M. Sakuda , R. Yamaguchi , T. Yano , Y. Kuno , S. B. Kim , B. S. Yang , H. Okazawa , Y. Choi , K. Nishijima , M. Koshiba , Y. Totsuka , M. Yokoyama , K. Martens , M. R. Vagins , J. F. Martin , P. de Perio , A. Konaka , M. J. Wilking , S. Chen , Y. Heng , H. Sui , Z. Yang , H. Zhang , Y. Zhenwei , K. Connolly , M. Dziomba , R. J. Wilkes

Scalable photonic quantum technologies require highly efficient sources of single photons on demand. Although much progress has been done in the field within the last decade, the requirements impose stringent conditions on the efficiency of…

Next generation multi-ton scale noble liquid experiments have the unique opportunity to discover dark matter particles at the TeV scale, reaching the sensitivity of 10^-48 cm2 in the WIMP nucleon scattering cross-section. A prerequisite…

Instrumentation and Detectors · Physics 2016-01-07 S. Catalanotti , A. G. Cocco , G. Covone , M. D Incecco , G. Fiorillo , G. Korga , B. Rossi , S. Walker

To cope with the challenging environment of the planned high luminosity upgrade of the Large Hadron Collider (HL-LHC), scheduled to start operation in 2029, CMS will replace its entire tracking system. The requirements for the tracker are…

Instrumentation and Detectors · Physics 2022-12-12 The Tracker Group of the CMS Collaboration

Single photon detection played an important role in the development of quantum optics. Its implementation in the microwave domain is challenging because the photon energy is 5 orders of magnitude smaller. In recent years, significant…