Related papers: Cryogenic environment and performance for testing …
We developed a system that continuously maintains a cryocooler for long periods on a rotating table. A cryostat that holds the cryocooler is set on the table. A compressor is located on the ground and supplies high-purity (> 99.999%) and…
The scientific performance of the Planck Low Frequency Instrument (LFI) after one year of in-orbit operation is presented. We describe the main optical parameters and discuss photometric calibration, white noise sensitivity, and noise…
Noise filtering is an essential part for measurement of quantum phenomena at extremely low temperatures. Here, we present the design of a filter which can be installed in space constrained cryogenic environment containing a large number of…
Monitoring motion originating from ultra low-temperature cooling systems like cryocoolers is important for vibration sensitive cryogenic experiments like KAGRA. Since no commercial cryogenic accelerometers are available, we developed a…
In this paper we discuss the linearity response of the Planck-LFI receivers, with particular reference to signal compression measured on the 30 and 44 GHz channels. In the article we discuss the various sources of compression and present a…
The growing number of phased array feeds (PAF) being built for radio astronomy demonstrates an increasing need for low noise amplifiers (LNA) that are designed for repeatability, low noise, and ease of manufacture. Specific design features…
The LHCb experiment at CERN has been upgraded for the Run 3 operation of the Large Hadron Collider (LHC). A new concept of tracking detector based on Scintillating Fibres (SciFi) read out with multichannel silicon photomultipliers (SiPMs)…
This paper presents an ultra-low noise L-band radio astronomical cryogenic receiver for FAST telescope. The development of key low noise microwave parts of Coupling-LNA and conical quad-ridge OMT and reasonable system integration achieve…
We describe the processing of data from the Low Frequency Instrument (LFI) used in production of the Planck Early Release Compact Source Catalogue (ERCSC). In particular, we discuss the steps involved in reducing the data from telemetry…
The Planck High Frequency Instrument (HFI) spectral response was determined through a series of ground based tests conducted with the HFI focal plane in a cryogenic environment prior to launch. The main goal of the spectral transmission…
The use of low-temperature detectors, such as cryogenic calorimeters, has pioneered the recent advancements in low-energy rare event searches. These detectors provide a low-noise environment essential for the direct detection of dark matter…
Current precision experiments with single (anti)protons to test CPT symmetry progress at a rapid pace, but are complicated by the need to cool particles to sub-thermal energies. We describe a cryogenic Penning-trap setup for $^9$Be$^+$ ions…
Data on board the future PLANCK Low Frequency Instrument (LFI), to measure the Cosmic Microwave Background (CMB) anisotropies, consist of $N$ differential temperature measurements, expanding a range of values we shall call $R$. Preliminary…
A prototype device capable of moving a radioactive calibration source to multiple positions was operated at millikelvin temperatures using a modified commercial stepper motor. It was developed as an in-situ calibration strategy for…
After the Planck mission's launch in 2009, bolometers of its High Frequency Instrument (HFI) were considerably affected by cosmic rays, which necessitated several years of post-treatment to clean the data. To study the susceptibility of…
To asses stability against 1/f noise, the Low Frequency Instrument (LFI) onboard the Planck mission will acquire data at a rate much higher than the data rate allowed by its telemetry bandwith of 35.5 kbps. The data are processed by an…
In the pursuit of quantum computing, solid-state quantum systems, particularly superconducting ones, have made remarkable advancements over the past two decades. However, achieving fault-tolerant quantum computing for next-generation…
We present two simple cryogenic RF ion trap systems in which cryogenic temperatures and ultra high vacuum pressures can be reached in as little as 12 hours. The ion traps are operated either in a liquid helium bath cryostat or in a low…
Although it is often believed that the coldness of space is ideally suited for performing measurements at cryogenic temperatures, this must be regarded with caution for two reasons: Firstly, the sensitive instrument must be completely…